Colin Percival 20d1a304b3 Reduce the Xen timecounter from 1GHz to 2^-9 GHz, thereby increasing the
timecounter period from 2^32 ns (~4.3s) to 2^41 ns (~36m39s).  Some time
sharing systems can skip clock interrupts for a few seconds when under
load (e.g., if we've recently used more than our fair share of CPU and
someone else wants a burst of CPU) and we were losing time in quanta of
2^32 ns due to timecounter wrapping.

Increasing the timecounter period up to 2^41 ns is definitely overkill,
but we still have microsecond timecounter precision, and anyone using
paravirtualized hardware when they need submicrosecond timing is crazy.
2010-12-11 22:33:33 +00:00
..