Mitsuru IWASAKI cfd820d382 Fix a bug about the cooling system controlling in acpi_thermal driver.
Recent version of ACPI CA returns the package object which contains
object reference elements if the elements are named objects.
We need to be careful when you use acpi_ForeachPackageObject() in new
code...