Rick Macklem 72263475c4 Fix two known problems in clnt_rc.c, plus issues w.r.t. smp noted
during reading of the code. Change the code so that it never accesses
rc_connecting, rc_closed or rc_client when the rc_lock mutex is not held.
Also, it now performs the CLNT_CLOSE(client) and CLNT_RELEASE(client)
calls after the rc_lock mutex has been released, since those calls do
msleep()s with another mutex held. Change clnt_reconnect_call() so that
releasing the reference count is delayed until after the
"if (rc->rc_client == client)" check, so that rc_client cannot have been
recycled.

Tested by:	pho
Reviewed by:	dfr
Approved by:	kib (mentor)
2009-06-25 00:28:43 +00:00
..