[net80211] fix duration field; it's unsigned, but not long.

Submitted by:	Imre Vadasz <imre@vdsz.com>
Obtained from:	DragonflyBSD
This commit is contained in:
Adrian Chadd 2016-01-04 17:17:06 +00:00
parent 9a1b64d5a0
commit 098b3fe173

View File

@ -359,7 +359,7 @@ ieee80211_swscan_bg_scan(const struct ieee80211_scanner *scan,
duration = IEEE80211_SCAN_OFFCHANNEL;
IEEE80211_DPRINTF(vap, IEEE80211_MSG_SCAN,
"%s: %s scan, ticks %u duration %lu\n", __func__,
"%s: %s scan, ticks %u duration %u\n", __func__,
ss->ss_flags & IEEE80211_SCAN_ACTIVE ? "active" : "passive",
ticks, duration);