Add support for TOPOLOGY feature of virtio block device.
Passing through physical block size/offset from underlying storage allows guest to manage proper data and I/O alignment to improve performance. MFC after: 2 weeks
This commit is contained in:
parent
a12775b872
commit
214386b6e7
@ -64,7 +64,8 @@ __FBSDID("$FreeBSD$");
|
||||
|
||||
/* Capability bits */
|
||||
#define VTBLK_F_SEG_MAX (1 << 2) /* Maximum request segments */
|
||||
#define VTBLK_F_BLK_SIZE (1 << 6) /* cfg block size valid */
|
||||
#define VTBLK_F_BLK_SIZE (1 << 6) /* cfg block size valid */
|
||||
#define VTBLK_F_TOPOLOGY (1 << 10) /* Optimal I/O alignment */
|
||||
|
||||
/*
|
||||
* Host capabilities
|
||||
@ -72,6 +73,7 @@ __FBSDID("$FreeBSD$");
|
||||
#define VTBLK_S_HOSTCAPS \
|
||||
( VTBLK_F_SEG_MAX | \
|
||||
VTBLK_F_BLK_SIZE | \
|
||||
VTBLK_F_TOPOLOGY | \
|
||||
VIRTIO_RING_F_INDIRECT_DESC ) /* indirect descriptors */
|
||||
|
||||
/*
|
||||
@ -81,11 +83,19 @@ struct vtblk_config {
|
||||
uint64_t vbc_capacity;
|
||||
uint32_t vbc_size_max;
|
||||
uint32_t vbc_seg_max;
|
||||
uint16_t vbc_geom_c;
|
||||
uint8_t vbc_geom_h;
|
||||
uint8_t vbc_geom_s;
|
||||
struct {
|
||||
uint16_t cylinders;
|
||||
uint8_t heads;
|
||||
uint8_t sectors;
|
||||
} vbc_geometry;
|
||||
uint32_t vbc_blk_size;
|
||||
uint32_t vbc_sectors_max;
|
||||
struct {
|
||||
uint8_t physical_block_exp;
|
||||
uint8_t alignment_offset;
|
||||
uint16_t min_io_size;
|
||||
uint32_t opt_io_size;
|
||||
} vbc_topology;
|
||||
uint8_t vbc_writeback;
|
||||
} __packed;
|
||||
|
||||
/*
|
||||
@ -262,7 +272,7 @@ pci_vtblk_init(struct vmctx *ctx, struct pci_devinst *pi, char *opts)
|
||||
MD5_CTX mdctx;
|
||||
u_char digest[16];
|
||||
struct pci_vtblk_softc *sc;
|
||||
off_t size;
|
||||
off_t size, sts, sto;
|
||||
int fd;
|
||||
int sectsz;
|
||||
|
||||
@ -291,6 +301,7 @@ pci_vtblk_init(struct vmctx *ctx, struct pci_devinst *pi, char *opts)
|
||||
*/
|
||||
size = sbuf.st_size;
|
||||
sectsz = DEV_BSIZE;
|
||||
sts = sto = 0;
|
||||
if (S_ISCHR(sbuf.st_mode)) {
|
||||
if (ioctl(fd, DIOCGMEDIASIZE, &size) < 0 ||
|
||||
ioctl(fd, DIOCGSECTORSIZE, §sz)) {
|
||||
@ -300,7 +311,10 @@ pci_vtblk_init(struct vmctx *ctx, struct pci_devinst *pi, char *opts)
|
||||
}
|
||||
assert(size != 0);
|
||||
assert(sectsz != 0);
|
||||
}
|
||||
if (ioctl(fd, DIOCGSTRIPESIZE, &sts) == 0)
|
||||
ioctl(fd, DIOCGSTRIPEOFFSET, &sto);
|
||||
} else
|
||||
sts = sbuf.st_blksize;
|
||||
|
||||
sc = calloc(1, sizeof(struct pci_vtblk_softc));
|
||||
|
||||
@ -328,13 +342,19 @@ pci_vtblk_init(struct vmctx *ctx, struct pci_devinst *pi, char *opts)
|
||||
|
||||
/* setup virtio block config space */
|
||||
sc->vbsc_cfg.vbc_capacity = size / DEV_BSIZE; /* 512-byte units */
|
||||
sc->vbsc_cfg.vbc_seg_max = VTBLK_MAXSEGS;
|
||||
sc->vbsc_cfg.vbc_blk_size = sectsz;
|
||||
sc->vbsc_cfg.vbc_size_max = 0; /* not negotiated */
|
||||
sc->vbsc_cfg.vbc_geom_c = 0; /* no geometry */
|
||||
sc->vbsc_cfg.vbc_geom_h = 0;
|
||||
sc->vbsc_cfg.vbc_geom_s = 0;
|
||||
sc->vbsc_cfg.vbc_sectors_max = 0;
|
||||
sc->vbsc_cfg.vbc_seg_max = VTBLK_MAXSEGS;
|
||||
sc->vbsc_cfg.vbc_geometry.cylinders = 0; /* no geometry */
|
||||
sc->vbsc_cfg.vbc_geometry.heads = 0;
|
||||
sc->vbsc_cfg.vbc_geometry.sectors = 0;
|
||||
sc->vbsc_cfg.vbc_blk_size = sectsz;
|
||||
sc->vbsc_cfg.vbc_topology.physical_block_exp =
|
||||
(sts > sectsz) ? (ffsll(sts / sectsz) - 1) : 0;
|
||||
sc->vbsc_cfg.vbc_topology.alignment_offset =
|
||||
(sto != 0) ? ((sts - sto) / sectsz) : 0;
|
||||
sc->vbsc_cfg.vbc_topology.min_io_size = 0;
|
||||
sc->vbsc_cfg.vbc_topology.opt_io_size = 0;
|
||||
sc->vbsc_cfg.vbc_writeback = 0;
|
||||
|
||||
/*
|
||||
* Should we move some of this into virtio.c? Could
|
||||
|
Loading…