Add a remark to the effect that a manually started relearn will always
result in the battery being completely drained, even in transparent learning mode. MFC in: 3 days Sponsored by: Sandvine Inc.
This commit is contained in:
parent
f13e3f2087
commit
252d859338
@ -573,6 +573,10 @@ Updates the flash on the controller with the firmware stored in
|
||||
A reboot is required for the new firmware to take effect.
|
||||
.It Cm start learn
|
||||
Start a battery relearn.
|
||||
Note that this seems to always result in the battery being completely drained,
|
||||
regardless of the BBU mode.
|
||||
In particular, the controller write cache will be disabled during the relearn
|
||||
even if transparent learning mode is enabled.
|
||||
.It Cm bbu Ar setting Ar value
|
||||
Update battery backup unit (BBU) properties related to battery relearning.
|
||||