Add acpi_thermal manual page,
because I asked about the unit of thermal zone-related value too freqently. Come on, mdoc police.
This commit is contained in:
parent
17cbb0b2fc
commit
62980ecc8b
@ -361,6 +361,7 @@ latency when an interrupt occurs.
|
||||
ACPI is only found and supported on i386/ia32, ia64, and amd64.
|
||||
.Sh SEE ALSO
|
||||
.Xr loader.conf 5 ,
|
||||
.Xr acpi_thermal.4 ,
|
||||
.Xr acpiconf 8 ,
|
||||
.Xr acpidump 8 ,
|
||||
.Xr config 8 ,
|
||||
|
104
share/man/man4/acpi_thermal.4
Normal file
104
share/man/man4/acpi_thermal.4
Normal file
@ -0,0 +1,104 @@
|
||||
.\"
|
||||
.\" Copyright (c) 2003 Takanori Watanabe.
|
||||
.\" All rights reserved.
|
||||
.\"
|
||||
.\" Redistribution and use in source and binary forms, with or without
|
||||
.\" modification, are permitted provided that the following conditions
|
||||
.\" are met:
|
||||
.\" 1. Redistributions of source code must retain the above copyright
|
||||
.\" notice, this list of conditions and the following disclaimer.
|
||||
.\" 2. Redistributions in binary form must reproduce the above copyright
|
||||
.\" notice, this list of conditions and the following disclaimer in the
|
||||
.\" documentation and/or other materials provided with the distribution.
|
||||
.\"
|
||||
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
|
||||
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
||||
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
||||
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
|
||||
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
||||
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
||||
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
||||
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
||||
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
||||
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
||||
.\" SUCH DAMAGE.
|
||||
.\"
|
||||
.\" $FreeBSD$
|
||||
.\"
|
||||
|
||||
.Dd July 2, 2001
|
||||
.Dt ACPI_THERMAL 4
|
||||
.Os
|
||||
.Sh NAME
|
||||
.Nm acpi_thermal
|
||||
.Nd ACPI Thermal Management Support Subsystem
|
||||
.Sh SYNOPSIS
|
||||
.Cd "device acpi"
|
||||
.Pp
|
||||
.Sh DESCRIPTION
|
||||
The
|
||||
.Nm
|
||||
driver provides ACPI thermal handling feature as a part of
|
||||
ACPI module. This module has sysctl interface and devd notification
|
||||
interface. Sysctls export ACPI objects as is.
|
||||
The
|
||||
.Nm
|
||||
driver also activate active cooling system in accordance with appropriate
|
||||
acpi object.
|
||||
.Sh SYSCTLS
|
||||
.Bl -tag -width indent
|
||||
.It Va hw.acpi.thermal.tz%d.active
|
||||
Current active system running state.
|
||||
.It Va hw.acpi.thermal.tz%d.thermal_flags
|
||||
Current thermal zone status. This is bit-masked values.
|
||||
.It Va hw.acpi.thermal.tz%d.temperature
|
||||
exports _TMP object that means current temperature.
|
||||
.It Va hw.acpi.thermal.tz%d._PSV
|
||||
exports _PSV object that means the temperature to start
|
||||
passive cooling by throtting down CPU etc..
|
||||
.It Va hw.acpi.thermal.tz%d._HOT
|
||||
exports _HOT object that means the temperature to
|
||||
start critical suspend to disk
|
||||
.It Va hw.acpi.thermal.tz%d._CRT
|
||||
exports _CRT object that means the temperature to
|
||||
start critical shutdown.
|
||||
.It Va hw.acpi.thermal.tz%d._ACx
|
||||
exports _ACx objects that objects that means active
|
||||
cooling start values. The earlier value means the strengest
|
||||
active cooling temperature.
|
||||
.El
|
||||
All temperature is represents as tenth of Kelvin. For example
|
||||
300.0K is represented as by the integer 3000. To convert to Centigrade,
|
||||
the formula is (x - 2731.5) / 10.
|
||||
.Sh NOTIFYS
|
||||
Notifies are passed as a string beginning with
|
||||
"!system=ACPI subsystem=Thermal" the thermal zone instance
|
||||
is distingushed by ACPI object path in "type=" argument. The notify
|
||||
value is passed in "notify=" argument.
|
||||
|
||||
.Bl -tag -width indent
|
||||
.It Va 0x80
|
||||
Temperature change.
|
||||
.It Va 0x81
|
||||
Trip point change.
|
||||
.It Va 0x82
|
||||
Device Lists change.
|
||||
.El
|
||||
.Sh SEE ALSO
|
||||
.Xr acpi 4
|
||||
.Rs
|
||||
.%A "Compaq Computer Corporation"
|
||||
.%A "Intel Corporation"
|
||||
.%A "Microsoft Corporation"
|
||||
.%A "Phoenix Technologies Ltd."
|
||||
.%A "Toshiba Corporation"
|
||||
.%D August 25, 2003
|
||||
.%T "Advanced Configuration and Power Interface Specification"
|
||||
.%O http://acpi.info/spec.htm
|
||||
.Re
|
||||
.Sh AUTHORS
|
||||
.An Michael Smith
|
||||
.Pp
|
||||
This manual page was written by
|
||||
.Pp
|
||||
.An Takanori Watanabe
|