Fix the initial calibration sample count when doing ADC calibrations.
Obtained from: Atheros Approved by: re (kib)
This commit is contained in:
parent
e875139a4f
commit
78b72aff33
@ -42,14 +42,14 @@ static const HAL_PERCAL_DATA ar9280_iq_cal = { /* single sample */
|
||||
static const HAL_PERCAL_DATA ar9280_adc_gain_cal = { /* single sample */
|
||||
.calName = "ADC Gain", .calType = ADC_GAIN_CAL,
|
||||
.calNumSamples = MIN_CAL_SAMPLES,
|
||||
.calCountMax = PER_MIN_LOG_COUNT,
|
||||
.calCountMax = PER_MAX_LOG_COUNT,
|
||||
.calCollect = ar5416AdcGainCalCollect,
|
||||
.calPostProc = ar5416AdcGainCalibration
|
||||
};
|
||||
static const HAL_PERCAL_DATA ar9280_adc_dc_cal = { /* single sample */
|
||||
.calName = "ADC DC", .calType = ADC_DC_CAL,
|
||||
.calNumSamples = MIN_CAL_SAMPLES,
|
||||
.calCountMax = PER_MIN_LOG_COUNT,
|
||||
.calCountMax = PER_MAX_LOG_COUNT,
|
||||
.calCollect = ar5416AdcDcCalCollect,
|
||||
.calPostProc = ar5416AdcDcCalibration
|
||||
};
|
||||
|