Fix an issue with service(8) where utilities such as screen(1) and tmux(1)
would behave differently when utilizing rc-script was invoked manually vs. service(8). The issue being that these utilities require the TERM environ variable to be set and service(8) was not passing it down. Reported by: Michael Dexter <editor@callfortesting.org> PR: bin/191869 Reviewed by: allanjude MFC after: 3 days X-MFC-to: stable/10, stable/9
This commit is contained in:
parent
44eb893659
commit
829dd7fb63
@ -139,7 +139,7 @@ cd /
|
||||
for dir in /etc/rc.d $local_startup; do
|
||||
if [ -x "$dir/$script" ]; then
|
||||
[ -n "$VERBOSE" ] && echo "$script is located in $dir"
|
||||
exec env -i HOME=/ PATH=/sbin:/bin:/usr/sbin:/usr/bin $dir/$script $*
|
||||
exec env -i HOME=/ PATH=/sbin:/bin:/usr/sbin:/usr/bin TERM="$TERM" $dir/$script $*
|
||||
fi
|
||||
done
|
||||
|
||||
|
Loading…
Reference in New Issue