Document that syslogd -v has no effect when RFC 5424 mode is enabled.

The variable it sets, LogFacPri, is only used in the RFC 3164 formatting
codepath.

PR:		229457
Reported by:	Andre Albsmeier
MFC after:	1 week
This commit is contained in:
Ed Schouten 2018-07-02 11:02:27 +00:00
parent 8a66bdb414
commit 8ab684e234

View File

@ -28,7 +28,7 @@
.\" @(#)syslogd.8 8.1 (Berkeley) 6/6/93 .\" @(#)syslogd.8 8.1 (Berkeley) 6/6/93
.\" $FreeBSD$ .\" $FreeBSD$
.\" .\"
.Dd April 15, 2018 .Dd July 2, 2018
.Dt SYSLOGD 8 .Dt SYSLOGD 8
.Os .Os
.Sh NAME .Sh NAME
@ -348,6 +348,10 @@ logged with each locally-written message.
If specified more than once, If specified more than once,
the names of the facility and priority are logged with each locally-written the names of the facility and priority are logged with each locally-written
message. message.
.Pp
This option only affects the formatting of RFC 3164 messages.
Messages formatted according to RFC 5424 always include a
facility/priority number.
.El .El
.Pp .Pp
The The