[PowerPC] Fix setting of time in OPAL

There were multiple bugs in the OPAL RTC code which had never been
discovered, as the default configuration of OPAL machines is to
have the BMC / FSP control the RTC.

* Fix calling convention for setting the time -- the variables are passed
directly in CPU registers, not via memory.

* Fix bug in the bcd encoding routines. (from jhibbits)

Tested on POWER9 Talos II (BE) and POWER9 Blackbird (LE).

Reviewed by:	jhibbits (in irc)
Sponsored by:	Tag1 Consulting, Inc.
This commit is contained in:
bdragon 2020-09-10 01:49:53 +00:00
parent 3b413429aa
commit c2230e2ff0

View File

@ -256,15 +256,15 @@ bin2bcd32(int bin)
int tmp;
tmp = bin % 100;
out += bin2bcd(tmp) * 1;
out += bin2bcd(tmp) * 0x1;
bin = bin / 100;
tmp = bin % 100;
out += bin2bcd(tmp) * 100;
out += bin2bcd(tmp) * 0x100;
bin = bin / 100;
tmp = bin % 100;
out += bin2bcd(tmp) * 10000;
out += bin2bcd(tmp) * 0x10000;
return (out);
}
@ -297,7 +297,7 @@ opal_gettime(device_t dev, struct timespec *ts)
ct.day = bcd2bin((ymd & 0x000000ff) >> 0);
ct.mon = bcd2bin((ymd & 0x0000ff00) >> 8);
ct.year = bcd2bin32((ymd & 0xffff0000) >> 16);
ct.year = bcd2bin32((ymd & 0xffff0000) >> 16);
return (clock_ct_to_ts(&ct, ts));
}
@ -321,11 +321,12 @@ opal_settime(device_t dev, struct timespec *ts)
hmsm |= ((uint64_t)bin2bcd(ct.min) << 48);
hmsm |= ((uint64_t)bin2bcd(ct.hour) << 56);
hmsm = htobe64(hmsm);
ymd = htobe32(ymd);
/*
* We do NOT swap endian here, because the values are being sent
* via registers instead of indirect via memory.
*/
do {
rv = opal_call(OPAL_RTC_WRITE, vtophys(&ymd), vtophys(&hmsm));
rv = opal_call(OPAL_RTC_WRITE, ymd, hmsm);
if (rv == OPAL_BUSY_EVENT) {
rv = opal_call(OPAL_POLL_EVENTS, 0);
pause("opalrtc", 1);