Whitespace change: reformat to avoid hard sentence breaks and long
lines.
This commit is contained in:
parent
9ccbd450e8
commit
ddf48d5ff5
@ -60,46 +60,62 @@ help
|
||||
.Sh DESCRIPTION
|
||||
The
|
||||
.Nm
|
||||
utility provides status monitoring and management functions for devices attached
|
||||
utility provides status monitoring and management functions
|
||||
for devices attached
|
||||
to the
|
||||
.Xr mlx 4
|
||||
driver.
|
||||
.Pp
|
||||
Controller names are of the form "mlxN" where N is the unit number of the controller.
|
||||
Drive names are of the form "mlxdN" where N is the unit number of the drive. Do not
|
||||
specify the path to a device node.
|
||||
Controller names are of the form "mlxN"
|
||||
where N is the unit number of the controller.
|
||||
Drive names are of the form "mlxdN"
|
||||
where N is the unit number of the drive.
|
||||
Do not specify the path to a device node.
|
||||
.Pp
|
||||
.Bl -tag -width status
|
||||
.It status
|
||||
Print the status of controllers and system drives. If one or more drives are specified,
|
||||
only print information about these drives, otherwise print information about all controllers
|
||||
and drives in the system. With the
|
||||
Print the status of controllers and system drives.
|
||||
If one or more drives are specified,
|
||||
only print information about these drives,
|
||||
otherwise print information
|
||||
about all controllers and drives in the system.
|
||||
With the
|
||||
.Fl v
|
||||
flag, display much more verbose information.
|
||||
With the
|
||||
.Fl q
|
||||
flag, do not print any output. This command returns 0 if all drives tested are online, 1
|
||||
if one or more drives are critical and 2 if one or more are offline.
|
||||
flag, do not print any output.
|
||||
This command returns
|
||||
0 if all drives tested are online,
|
||||
1 if one or more drives are critical and
|
||||
2 if one or more are offline.
|
||||
.It rescan
|
||||
Rescan one or more controllers for non-attached system drives (eg. drives that have been
|
||||
detached or created subsequent to driver initialisation). If the
|
||||
Rescan one or more controllers for non-attached system drives
|
||||
(eg. drives that have been
|
||||
detached or created subsequent to driver initialisation).
|
||||
If the
|
||||
.Fl a
|
||||
flag is supplied, rescan all controllers in the system.
|
||||
.It detach
|
||||
Detach one or more system drives. Drives must be unmounted and not opened by any other
|
||||
utility for this command to succeed. If the
|
||||
Detach one or more system drives.
|
||||
Drives must be unmounted
|
||||
and not opened by any other utility for this command to succeed.
|
||||
If the
|
||||
.Fl a
|
||||
flag is supplied, detach all system drives from the nominated controller.
|
||||
.It check
|
||||
Initiate a consistency check and repair pass on a redundant system drive (eg. RAID1 or RAID5).
|
||||
The controller will scan the system drive and repair any inconsistencies. This command
|
||||
returns immediately; use the
|
||||
Initiate a consistency check and repair pass on a redundant system drive
|
||||
(eg. RAID1 or RAID5).
|
||||
The controller will scan the system drive and repair any inconsistencies.
|
||||
This command returns immediately;
|
||||
use the
|
||||
.Ar status
|
||||
command to monitor the progress of the check.
|
||||
.It config
|
||||
Print the current configuration from the nominated controller. This command will be
|
||||
updated to allow addition/deletion of system drives from a configuration in a future
|
||||
release.
|
||||
Print the current configuration from the nominated controller.
|
||||
This command will be updated
|
||||
to allow addition/deletion of system drives from a configuration
|
||||
in a future release.
|
||||
.It help
|
||||
Print usage information for
|
||||
.Ar command .
|
||||
|