Clean up language.
Reviewed by: rik
This commit is contained in:
parent
5e189e571a
commit
fb7ca181a0
@ -1,150 +1,161 @@
|
|||||||
|
.\" Copyright (c) 2002-2004 Roman Kurakin <rik@cronyx.ru>
|
||||||
|
.\" Copyright (c) 2002-2004 Cronyx Engineering
|
||||||
|
.\" All rights reserved.
|
||||||
|
.\"
|
||||||
|
.\" This software is distributed with NO WARRANTIES, not even the implied
|
||||||
|
.\" warranties for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
|
||||||
|
.\"
|
||||||
|
.\" Authors grant any other persons or organisations a permission to use,
|
||||||
|
.\" modify and redistribute this software in source and binary forms,
|
||||||
|
.\" as long as this message is kept with the software, all derivative
|
||||||
|
.\" works or modified versions.
|
||||||
|
.\"
|
||||||
.\" $FreeBSD$
|
.\" $FreeBSD$
|
||||||
.Dd November 21, 2003
|
.Dd May 19, 2004
|
||||||
.Dt SCONFIG 8 i386
|
.Dt SCONFIG 8 i386
|
||||||
.Os
|
.Os
|
||||||
.Sh NAME
|
.Sh NAME
|
||||||
.Nm sconfig
|
.Nm sconfig
|
||||||
.Nd channel configuration utility for Cronyx adapters
|
.Nd "channel configuration utility for Cronyx adapters"
|
||||||
.Sh SYNOPSIS
|
.Sh SYNOPSIS
|
||||||
.Nm
|
.Nm
|
||||||
.Op Fl aimsxeftuc
|
.Op Fl aimsxeftuc
|
||||||
.Op Ar device
|
.Op Ar device
|
||||||
.Op Ar data rate options
|
.Op Ar data_rate_options
|
||||||
.Op Ar protocol options ...
|
.Op Ar protocol_options ...
|
||||||
.Op Ar interface options ...
|
.Op Ar interface_options ...
|
||||||
.Sh DESCRIPTION
|
.Sh DESCRIPTION
|
||||||
The
|
The
|
||||||
.Nm
|
.Nm
|
||||||
utility is used for configuring the channel options of the Cronyx
|
utility is used for configuring the channel options of the Cronyx
|
||||||
adapters.
|
adapters.
|
||||||
In asynchronous mode all the parameters should be set by standard
|
In asynchronous mode, all parameters should be set using the standard
|
||||||
.Xr stty 1
|
.Xr stty 1
|
||||||
utility, with
|
utility.
|
||||||
.Nm
|
With
|
||||||
you could set only few of them (see below).
|
.Nm ,
|
||||||
|
it is only possible to set some of them (see below).
|
||||||
.Pp
|
.Pp
|
||||||
Some of the options could be set only on free channels, that is the
|
Some of the options can be set only on free channels,
|
||||||
corresponding network interface in
|
that is when the corresponding network interface is in the
|
||||||
.Ar down
|
.Cm down
|
||||||
state in the synchronous mode, and in the asynchronous mode the asynchronous
|
state in the synchronous mode,
|
||||||
terminal device
|
and the terminal device
|
||||||
.Pa /dev/tty*
|
.Pa /dev/tty*
|
||||||
closed.
|
is closed in asynchronous mode.
|
||||||
.Pp
|
.Pp
|
||||||
Other channel options could be changed
|
Other channel options can be changed
|
||||||
.Dq "on the fly" .
|
.Dq "on the fly" .
|
||||||
Generally, the channel options are set up during the operating system startup,
|
Generally, the channel options are set up during the operating system startup,
|
||||||
for example from the
|
for example, from the
|
||||||
.Pa /etc/rc
|
.Pa /etc/rc
|
||||||
file.
|
script.
|
||||||
.Pp
|
.Pp
|
||||||
Note, that not all options have a sense for every particular
|
Note that not all options make sense in every particular case,
|
||||||
case, and an attempt to set some of them can hang up the channel or
|
and an attempt to set some of them may hung up the channel
|
||||||
the whole adapter.
|
or the whole adapter.
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Ss "Information Options"
|
.Ss "Information Options"
|
||||||
You can specify only one of these options.
|
Only one of these options can be specified.
|
||||||
If information option is specified,
|
If information option is specified,
|
||||||
.Nm
|
.Nm
|
||||||
will show corresponding information and will ignore all other options,
|
will show the corresponding information and will ignore all other options,
|
||||||
except
|
except
|
||||||
.Ar device .
|
.Ar device .
|
||||||
See also description of the
|
See also the description of the
|
||||||
.Ar device .
|
.Ar device
|
||||||
|
argument.
|
||||||
.Bl -tag -width indent
|
.Bl -tag -width indent
|
||||||
.It <none>
|
.It <none>
|
||||||
This will show settings of the channel.
|
This will show settings of the channel.
|
||||||
.It Fl a
|
.It Fl a
|
||||||
Print all settings of the channel.
|
Print all settings of the channel.
|
||||||
.It Fl i
|
.It Fl i
|
||||||
Print interface settings, equal to the output of
|
Print interface settings, equal to the output of the
|
||||||
.Xr ifconfig 8
|
.Xr ifconfig 8
|
||||||
utility.
|
utility.
|
||||||
.It Fl m
|
.It Fl m
|
||||||
Print modem signal status.
|
Print modem signal status.
|
||||||
The description of all signals can be found in
|
The description of all signals can be found in any modem documentation.
|
||||||
any document related to the modems.
|
|
||||||
Only LE signal should be described.
|
Only LE signal should be described.
|
||||||
If this signal is On, than some what use channel.
|
If this signal is ON then the channel is busy.
|
||||||
If it is Off, than channel is free.
|
If it is OFF then the channel is free.
|
||||||
.It Fl s
|
.It Fl s
|
||||||
Print brief channel statistics.
|
Print brief channel statistics.
|
||||||
This is general statistics.
|
This is the generic statistics,
|
||||||
See also
|
see also the
|
||||||
.Fl x , e , f , t
|
.Fl x , e , f , t ,
|
||||||
and
|
and
|
||||||
.Fl u
|
.Fl u
|
||||||
options.
|
options.
|
||||||
For the description of output, see below.
|
For a description of the output, see below.
|
||||||
.Pp
|
.Pp
|
||||||
This statistics is very useful if something goes wrong.
|
This statistics is very useful if something goes wrong.
|
||||||
For example, if you
|
For example, if all interrupt counters are zero then the device
|
||||||
have no any interrupts, than you use interrupt that is not registered in BIOS
|
was configured to use an interrupt that was not registered in the
|
||||||
for use with ISA bus.
|
BIOS for use with the ISA bus.
|
||||||
.It Fl x
|
.It Fl x
|
||||||
Print full channel statistics.
|
Print full channel statistics.
|
||||||
This options allows to see some more counters,
|
This options prints additinal counters,
|
||||||
but with less precision than with the
|
but with less precision than with the
|
||||||
.Fl s
|
.Fl s
|
||||||
option.
|
option.
|
||||||
.It Fl e
|
.It Fl e
|
||||||
Print brief E1/G703 statistics.
|
Print brief E1/G703 statistics.
|
||||||
If you select this option, you will get
|
If this option is selected, the
|
||||||
statistics accumulated for period of time equal to 15 minutes.
|
statistics accumulated over the last 15 minutes is printed.
|
||||||
For the
|
For a description of the output, see below.
|
||||||
description of output, see below.
|
|
||||||
.It Fl f
|
.It Fl f
|
||||||
Print full E1/G703 statistics.
|
Print full E1/G703 statistics.
|
||||||
This option shows all E1/G703 statistics that
|
This option shows all E1/G703 statistics that the
|
||||||
shows previous option
|
.Fl e
|
||||||
.Pq Fl e ,
|
option shows,
|
||||||
but also total statistics for whole period of time and statistics for 24
|
plus total statistics for the whole period of time and statistics for
|
||||||
hours (if available).
|
last 24 hours (if available).
|
||||||
For the description of output, see below.
|
For a description of the output, see below.
|
||||||
.It Fl t
|
.It Fl t
|
||||||
Print brief E3/T3/STS-1 statistics.
|
Print brief E3/T3/STS-1 statistics.
|
||||||
If you select this option, you will
|
If this option is selected, the
|
||||||
get statistics accumulated for period of time equal to 15 minutes.
|
statistics accumulated over the last 15 minutes is printed.
|
||||||
For
|
For a description of the output, see below.
|
||||||
the description of output, see below.
|
|
||||||
.It Fl u
|
.It Fl u
|
||||||
Print full E3/T3/STS-1 statistics.
|
Print full E3/T3/STS-1 statistics.
|
||||||
This option shows all E3/T3/STS-1
|
This option shows all E3/T3/STS-1 statistics that the
|
||||||
statistics that shows previous option
|
.Fl t
|
||||||
.Pq Fl t ,
|
option shows,
|
||||||
but also total statistics for whole period of time and statistics for 24
|
plus total statistics for the whole period of time and statistics for
|
||||||
hours (if available).
|
last 24 hours (if available).
|
||||||
For the description of output, see below.
|
For a description of the output, see below.
|
||||||
.It Fl c
|
.It Fl c
|
||||||
Cleans all kind of statistics.
|
Cleans all kind of statistics.
|
||||||
.El
|
.El
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Ss "Device Selection"
|
.Ss "Device Selection"
|
||||||
Device is equal to the name of the interface that is used for a name of
|
The device is selected using the name of the network interface,
|
||||||
the interface that is sees
|
as shown by
|
||||||
.Xr ifconfig 8 .
|
.Xr ifconfig 8 .
|
||||||
The channel number depends on the order of loading drivers by the system.
|
The channel number depends on the order the drivers were loaded into the system.
|
||||||
Sometimes people confuse channel number and adapter number because of the
|
Sometimes people confuse channel number and adapter number because of the
|
||||||
same spelling.
|
same spelling.
|
||||||
Adapter number appears in kernel context, channel number
|
The adapter number appears in the kernel context, while the channel number
|
||||||
in configuration context.
|
is in the configuration context.
|
||||||
.Bl -tag -width indent
|
.Bl -tag -width indent
|
||||||
.It <none>
|
.It <none>
|
||||||
You can omit device name only if you want to get information.
|
If the device name is omitted,
|
||||||
This will cause
|
.Nm
|
||||||
printing information about all available channels of Cronyx adapters.
|
will print information about all channels of all Cronyx adapters
|
||||||
In the
|
available in the system.
|
||||||
case you want to make some settings you MUST specify device name.
|
If some settings need to be made, the device name must be specified.
|
||||||
.It Li cx##
|
.It Li cx Ns Ar ##
|
||||||
This is the channel name for the Sigma family of Cronyx adapters.
|
This is the channel name for the Sigma family of Cronyx adapters.
|
||||||
(ISA bus.)
|
(ISA bus.)
|
||||||
.It Li ct##
|
.It Li ct Ns Ar ##
|
||||||
This is the channel name for the Tau family of Cronyx adapters.
|
This is the channel name for the Tau family of Cronyx adapters.
|
||||||
(ISA bus.)
|
(ISA bus.)
|
||||||
.It Li cp##
|
.It Li cp Ns Ar ##
|
||||||
This is the channel name for the Tau-PCI family of Cronyx adapters.
|
This is the channel name for the Tau-PCI family of Cronyx adapters.
|
||||||
(PCI bus.)
|
(PCI bus.)
|
||||||
.It Li ce##
|
.It Li ce Ns Ar ##
|
||||||
This is the channel name for the Tau32-PCI family of Cronyx adapters.
|
This is the channel name for the Tau32-PCI family of Cronyx adapters.
|
||||||
(PCI bus.)
|
(PCI bus.)
|
||||||
.El
|
.El
|
||||||
@ -152,261 +163,278 @@ This is the channel name for the Tau32-PCI family of Cronyx adapters.
|
|||||||
.Ss "Data Rate Options"
|
.Ss "Data Rate Options"
|
||||||
.Bl -tag -width indent
|
.Bl -tag -width indent
|
||||||
.It Ar value
|
.It Ar value
|
||||||
In case of nonzero value it will cause setting data rate to given value and
|
A non-zero value will set the data rate to a given value
|
||||||
setting the internal clock source of the synchronization (in synchronous mode).
|
in asynchronous mode,
|
||||||
Zero value is equal to the
|
and will set the date rate and internal clock source of synchronization
|
||||||
.Cm extclock .
|
in synchronous mode.
|
||||||
The transmitted data (TXD) are synchronized using the internal on-board timing
|
A zero value is equivalent to specifying the
|
||||||
|
.Cm extclock
|
||||||
|
option.
|
||||||
|
The transmitted data (TxD) are synchronized using the internal on-board timing
|
||||||
generator, the internally generated timing signal is driven on the TXCOUT pin,
|
generator, the internally generated timing signal is driven on the TXCOUT pin,
|
||||||
and the signal on the TXCIN pin is ignored.
|
and the signal on the TXCIN pin is ignored.
|
||||||
This mode is used for direct
|
This mode is used for direct
|
||||||
terminal-to-terminal communication, e.g., for connecting two computers together
|
terminal-to-terminal communication, e.g., when connecting two computers together
|
||||||
in a synchronous mode via relatively short cable.
|
in synchronous mode with a relatively short cable.
|
||||||
This method should also be
|
This method should also be
|
||||||
used for testing channels with an external loopback connector.
|
used for testing channels with an external loopback connector.
|
||||||
.It Cm extclock
|
.It Cm extclock
|
||||||
Set the external timing clock source of synchronous channels.
|
Set the external timing clock source for synchronous channels.
|
||||||
External clock
|
External clock mode is the most commonly used method for connecting
|
||||||
mode is the most common method for connecting external modem hardware.
|
external modem hardware.
|
||||||
In this
|
In this mode,
|
||||||
mode the external timing signal is received on TXCIN pin of the connector,
|
the external timing signal is received on the TXCIN pin of the connector,
|
||||||
and it is used as a synchronization clock for transmitting data (TXD).
|
and it is used as a synchronization clock for transmitting data (TxD).
|
||||||
|
.Pp
|
||||||
|
Note: in
|
||||||
|
.Cm extclock
|
||||||
|
mode, the device cannot determine the value of the external timing clock
|
||||||
|
since it does not have the built-in clock gauge.
|
||||||
.El
|
.El
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Ss "Protocol Options"
|
.Ss "Protocol Options"
|
||||||
Note.
|
Note: these option can only be used on a free channel, and they require
|
||||||
These option could be set only if channel is free and they requires
|
specifying the device name.
|
||||||
specifying of the device name.
|
|
||||||
.Bl -tag -width indent
|
.Bl -tag -width indent
|
||||||
.It Cm async
|
.It Cm async
|
||||||
Set asynchronous protocol (or mode).
|
|
||||||
In this mode Cronyx adapters behave as a
|
|
||||||
usual serial devices and you may work with them using usual serial utilities.
|
|
||||||
All asynchronous settings are performed via serial configuration utilities.
|
|
||||||
With
|
|
||||||
.Nm
|
|
||||||
you may set only a few of them.
|
|
||||||
See also
|
|
||||||
.Xr stty 1 .
|
|
||||||
(Only for Sigma family.)
|
(Only for Sigma family.)
|
||||||
|
Select the asynchronous protocol (or mode).
|
||||||
|
In this mode, Cronyx adapters behave as normal serial devices,
|
||||||
|
and standard serial communications utilities can be used to
|
||||||
|
work with them.
|
||||||
|
All asynchronous settings should be set using the standard
|
||||||
|
serial communications configuration utilities, e.g.,
|
||||||
|
.Xr stty 1 .
|
||||||
|
With
|
||||||
|
.Nm ,
|
||||||
|
it is only possible to set some of them.
|
||||||
.It Cm cisco
|
.It Cm cisco
|
||||||
Set the Cisco HDLC synchronous protocol.
|
Select the Cisco HDLC synchronous protocol.
|
||||||
.It Cm fr
|
.It Cm fr
|
||||||
Set the Frame Relay synchronous protocol
|
Select the Frame Relay synchronous protocol
|
||||||
.Tn ( ANSI
|
.Tn ( ANSI
|
||||||
T1.617 Annex D).
|
T1.617 Annex D).
|
||||||
.It Cm ppp
|
.It Cm ppp
|
||||||
Set the PPP synchronous protocol.
|
Select the synchronous PPP protocol.
|
||||||
Parameters to the PPP could be set by the
|
PPP parameters can be configured using the
|
||||||
command
|
.Xr spppcontrol 8
|
||||||
.Xr spppcontrol 8 .
|
utility.
|
||||||
.It Sm Cm keepalive No = Bro Cm on , off Brc Sm
|
.It Sm Cm keepalive No = Bro Cm on , off Brc Sm
|
||||||
Turns on/off sending keepalive messages.
|
Turn on/off transmission of keepalive messages.
|
||||||
This option is used only for
|
This option is used only for synchronous PPP.
|
||||||
synchronous PPP.
|
If this option is
|
||||||
If this option is on, than PPP will periodically send
|
.Cm on ,
|
||||||
echo-request messages.
|
PPP will periodically send ECHO-REQUEST messages.
|
||||||
If it would not receive any echo-reply messages for
|
If it will not receive any ECHO-REPLY messages for
|
||||||
some (definite) period of time it will break connection.
|
some (definite) period of time it will break the connection.
|
||||||
It is used for
|
It is used for tracking the line state.
|
||||||
tracking line state.
|
|
||||||
.It Cm idle
|
.It Cm idle
|
||||||
You are using Netgraph.
|
This mode is reported when using Netgraph.
|
||||||
Protocol depends on connected module.
|
An actual protocol depends on the type of a connected Netgraph node,
|
||||||
|
and it cannot be changed with
|
||||||
|
.Nm .
|
||||||
.El
|
.El
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Ss "Interface Options"
|
.Ss "Interface Options"
|
||||||
Not all of these options could be set on running channel and not all of them
|
Not all of these options can be set on a busy channel, and not all of them
|
||||||
are suits to all kind of adapters/channels.
|
are applicable to all kinds of adapters/channels.
|
||||||
In all dual state options off is
|
For all dual-state options,
|
||||||
default value.
|
.Cm off
|
||||||
All this options is not applicable in asynchronous mode, except
|
is the default value.
|
||||||
|
None of these options can be used in the asynchronous mode,
|
||||||
|
except for the
|
||||||
.Cm debug
|
.Cm debug
|
||||||
option.
|
option.
|
||||||
.Bl -tag -width indent
|
.Bl -tag -width indent
|
||||||
.It Sm Cm port No = Bro Cm rs232 , v35 , rs449 Brc Sm
|
.It Sm Cm port No = Bro Cm rs232 , v35 , rs449 Brc Sm
|
||||||
Set port type for old Sigma models.
|
Set the port type for old Sigma models.
|
||||||
.It Sm Cm cfg No = Bro Cm A , B , C Brc Sm
|
.It Sm Cm cfg No = Bro Cm A , B , C Brc Sm
|
||||||
Set configuration for the adapter.
|
Set the configuration for the adapter.
|
||||||
This option could be set only for Tau/E1
|
This option can be used only with Tau/E1
|
||||||
and Tau/G703 and only if all channels are not running.
|
and Tau/G703 adapters, and only if all channels are free.
|
||||||
.Bl -tag -width ".Cm cfg Ns = Ns Cm A"
|
.Bl -tag -width ".Cm cfg Ns = Ns Cm A"
|
||||||
.It Cm cfg Ns = Ns Cm A
|
.It Cm cfg Ns = Ns Cm A
|
||||||
Two independent E1/G703 channels.
|
Two independent E1/G703 channels.
|
||||||
This is default setting.
|
This is the default setting.
|
||||||
.It Cm cfg Ns = Ns Cm B
|
.It Cm cfg Ns = Ns Cm B
|
||||||
(Only for ISA models.)
|
(Only for ISA models.)
|
||||||
For Tau/G703 this mean one G703 channel and one digital channel.
|
For Tau/G703 this means one G703 channel and one digital channel.
|
||||||
For Tau/E1 first physical channel divides on to subchannels.
|
For Tau/E1, the first physical channel is divided into two subchannels.
|
||||||
One of them
|
One of them goes to the first logical channel, another one goes to the
|
||||||
goes to the first logical channel and another one goes to the second physical
|
second physical channel.
|
||||||
channel.
|
Second (logical) channel is the digital channel.
|
||||||
Second (logical) channel is digital channel.
|
|
||||||
.It Cm cfg Ns = Ns Cm C
|
.It Cm cfg Ns = Ns Cm C
|
||||||
This configuration is used only for E1 models.
|
(Only for E1 models.)
|
||||||
In this case first
|
In this mode, first
|
||||||
physical channel consists of three data flows.
|
physical channel consists of three data flows.
|
||||||
Two of them go to two
|
Two of them go to the two (logical) channels.
|
||||||
(logical) channels.
|
|
||||||
The last one goes to the second physical channel.
|
The last one goes to the second physical channel.
|
||||||
On new
|
On newer models (Tau32-PCI, Tau-PCI/2E1 and Tau-PCI/4E1),
|
||||||
models (Tau32-PCI, Tau-PCI/2E1 and Tau-PCI/4E1) this configuration means single source
|
this programs the hardware to use a single source of synchronization
|
||||||
of synchronization and passing all unused (in both channels) timeslots from
|
and pass all unused (in both channels) timeslots from
|
||||||
one channel to other.
|
one channel to another.
|
||||||
.El
|
.El
|
||||||
.Pp
|
.Pp
|
||||||
For the detailed description of the configuration see
|
For a detailed description of available configuration modes,
|
||||||
your documentation to the adapter.
|
see the adapter documentation.
|
||||||
This option could not be set on running
|
This option cannot be set on a busy channel.
|
||||||
channel.
|
|
||||||
.It Sm Cm loop No = Bro Cm on , off Brc Sm
|
.It Sm Cm loop No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off internal loopback.
|
Turn on/off internal loopback.
|
||||||
This mode is useful for testing.
|
This mode is useful for debugging.
|
||||||
Switch on this
|
When this mode is
|
||||||
option and try to send something.
|
.Cm on ,
|
||||||
If you have no any interrupt, than, probably,
|
some data should be sent.
|
||||||
you forgot to switch using IRQ for PCI to ISA bus.
|
If no interrupts are generated, chances are that
|
||||||
Check your BIOS settings.
|
the corresponding IRQ configuration entry in the BIOS
|
||||||
|
was not switched from
|
||||||
|
.Dq Li "PCI/ISA PNP"
|
||||||
|
to
|
||||||
|
.Dq Li "Legacy ISA" .
|
||||||
.It Sm Cm rloop No = Bro Cm on , off Brc Sm
|
.It Sm Cm rloop No = Bro Cm on , off Brc Sm
|
||||||
(Only for Tau32-PCI and Tau-PCI/E3.)
|
(Only for Tau32-PCI and Tau-PCI/E3.)
|
||||||
Turn on/off remote loopback.
|
Turn on/off remote loopback feature.
|
||||||
This mode is also useful for testing.
|
This mode is also useful for debugging.
|
||||||
.It Sm Cm dpll No = Bro Cm on , off Brc Sm
|
.It Sm Cm dpll No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off digital phase locked loop mode (DPLL).
|
Turn on/off digital phase locked loop mode (DPLL).
|
||||||
When enabled, the receiver
|
When enabled, the receiver
|
||||||
timing clock signal is derived from the received data.
|
timing clock signal is derived from the received data.
|
||||||
Must be used with NRZI
|
Must be used with the NRZI
|
||||||
encoding, to avoid the synchronization loss.
|
encoding to avoid the synchronization loss.
|
||||||
.It Sm Cm nrzi No = Bro Cm on , off Brc Sm
|
.It Sm Cm nrzi No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off nrzi encoding.
|
Turn on/off NRZI encoding.
|
||||||
In off state nrz encoding is used.
|
If
|
||||||
|
.Cm off ,
|
||||||
|
NRZ encoding is used.
|
||||||
.Bl -tag -width "NRZI"
|
.Bl -tag -width "NRZI"
|
||||||
.It NRZ
|
.It NRZ
|
||||||
the zero
|
The zero bit is transmitted by the zero signal level,
|
||||||
bit is transmitted by the zero signal level, the one bit - by the positive
|
the one bit is transmitted by the positive signal level.
|
||||||
signal level.
|
|
||||||
.It NRZI
|
.It NRZI
|
||||||
the bit number zero is transmitted by the change of the
|
The zero bit is transmitted by the change of the signal
|
||||||
signal level, the one bit - by the constant signal level.
|
level, the one bit is by the constant signal level.
|
||||||
.El
|
Commonly used with the
|
||||||
.Pp
|
|
||||||
Commonly is used with
|
|
||||||
.Cm dpll Ns = Ns Cm on
|
.Cm dpll Ns = Ns Cm on
|
||||||
option.
|
option.
|
||||||
|
.El
|
||||||
.It Sm Cm invclk No = Bro Cm on , off Brc Sm
|
.It Sm Cm invclk No = Bro Cm on , off Brc Sm
|
||||||
Invert the both transmit and receive clock signals (Tau and Tau-PCI only).
|
(Tau and Tau-PCI only.)
|
||||||
|
Invert both the transmit and receive clock signals.
|
||||||
.It Sm Cm invrclk No = Bro Cm on , off Brc Sm
|
.It Sm Cm invrclk No = Bro Cm on , off Brc Sm
|
||||||
Invert the receive clock signals (Tau-PCI only).
|
(Tau-PCI only.)
|
||||||
|
Invert the receive clock signals.
|
||||||
.It Sm Cm invtclk No = Bro Cm on , off Brc Sm
|
.It Sm Cm invtclk No = Bro Cm on , off Brc Sm
|
||||||
Invert the transmit clock signals (Tau-PCI only).
|
(Tau-PCI only.)
|
||||||
|
Invert the transmit clock signals.
|
||||||
.It Sm Cm higain No = Bro Cm on , off Brc Sm
|
.It Sm Cm higain No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off increasing the E1 receiver non linear sensitivity to -30 dB (E1
|
(E1 only.)
|
||||||
only).
|
|
||||||
In of state the sensitivity is -12 dB.
|
In of state the sensitivity is -12 dB.
|
||||||
This allows increasing line
|
Turn on/off increasing the E1 receiver's non-linear sensitivity to -30dB.
|
||||||
distance.
|
This allows increasing of the line distance.
|
||||||
.It Sm Cm cablen No = Bro Cm on , off Brc Sm
|
.It Sm Cm cablen No = Bro Cm on , off Brc Sm
|
||||||
(Only for Tau-PCI/T3 and Tau-PCI/STS-1.)
|
(Tau-PCI/T3 and Tau-PCI/STS-1 only.)
|
||||||
Turn on/off adjusting transmit signal for long cable T3/STS-1.
|
Turn on/off adjusting of the transmit signal for a long cable T3/STS-1.
|
||||||
.It Sm Cm monitor No = Bro Cm on , off Brc Sm
|
.It Sm Cm monitor No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off increasing the E1 receiver lines sensitivity to -30 dB.
|
|
||||||
(Tau32-PCI, Tau-PCI/2E1 and Tau-PCI/4E1 only.)
|
(Tau32-PCI, Tau-PCI/2E1 and Tau-PCI/4E1 only.)
|
||||||
This could be used for interception
|
Turn on/off increasing of the E1 receiver's linear sensitivity to -30dB.
|
||||||
purposes.
|
This can be used for the interception purposes.
|
||||||
.It Sm Cm phony No = Bro Cm on , off Brc Sm
|
.It Sm Cm phony No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off the so-called phony mode.
|
|
||||||
(Tau32-PCI and Tau-PCI E1 family only.)
|
(Tau32-PCI and Tau-PCI E1 family only.)
|
||||||
|
Turn on/off the so-called
|
||||||
|
.Dq phony
|
||||||
|
mode.
|
||||||
This mode allows
|
This mode allows
|
||||||
receiving raw CEPT frames from E1 line.
|
receiving raw CEPT frames from the E1 line.
|
||||||
Raw frames could be accessed, for
|
Raw frames can be accessed, for example, with the raw protocol.
|
||||||
example, via raw protocol.
|
Packets would come at a rate of 500 frames per second
|
||||||
Packets would come at rate of 500 frames per second
|
|
||||||
with length
|
with length
|
||||||
.No 16* Ns Ar N
|
.No 16* Ns Ar N
|
||||||
(for Tau-PCI/E1 model), where
|
(for Tau-PCI/E1 model), where
|
||||||
.Ar N
|
.Ar N
|
||||||
is the number of timeslots.
|
is the number of timeslots.
|
||||||
For
|
For
|
||||||
Tau-PCI/2E1 and Tau-PCI/4E1 N should be equal to 32 independently from number of
|
Tau-PCI/2E1 and Tau-PCI/4E1,
|
||||||
|
.Ar N
|
||||||
|
should be equal to 32 regardless of the number of
|
||||||
used timeslots.
|
used timeslots.
|
||||||
.It Sm Cm unfram No = Bro Cm on , off Brc Sm
|
.It Sm Cm unfram No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off unframed mode.
|
|
||||||
(Tau32-PCI, Tau-PCI/2E1 and Tau-PCI/4E1 only.)
|
(Tau32-PCI, Tau-PCI/2E1 and Tau-PCI/4E1 only.)
|
||||||
|
Turn on/off unframed mode.
|
||||||
.Bl -tag -width ".Cm unfram Ns = Ns Cm off"
|
.Bl -tag -width ".Cm unfram Ns = Ns Cm off"
|
||||||
.It Cm unfram Ns = Ns Cm on
|
.It Cm unfram Ns = Ns Cm on
|
||||||
switches channel to unframed G.703 mode.
|
Switch channel to the unframed G.703 mode.
|
||||||
.It Cm unfram Ns = Ns Cm off
|
.It Cm unfram Ns = Ns Cm off
|
||||||
switches channel to framed E1 (G.704 mode).
|
Switch channel to the framed E1 (G.704) mode.
|
||||||
.El
|
.El
|
||||||
.It Sm Cm scrambler No = Bro Cm on , off Brc Sm
|
.It Sm Cm scrambler No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off the scrambling of G.703 data.
|
(Tau32-PCI, Tau-PCI/G.703, Tau-PCI/2E1, and
|
||||||
(Tau32-PCI, Tau-PCI/G.703 and Tau-PCI/2E1,
|
|
||||||
Tau-PCI/4E1 in unframed mode only.)
|
Tau-PCI/4E1 in unframed mode only.)
|
||||||
|
Turn on/off scrambling of the G.703 data.
|
||||||
.It Sm Cm use16 No = Bro Cm on , off Brc Sm
|
.It Sm Cm use16 No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off the usage of 16-th timeslot for data transmission.
|
|
||||||
(Tau32-PCI and Tau-PCI E1 family only.)
|
(Tau32-PCI and Tau-PCI E1 family only.)
|
||||||
Normally 16th timeslot is used for signaling information (multiframing CAS).
|
Turn on/off the usage of the 16th timeslot for data transmission.
|
||||||
|
Normally, the 16th timeslot is used for signalling information
|
||||||
|
(multiframing CAS).
|
||||||
.It Sm Cm crc4 No = Bro Cm on , off Brc Sm
|
.It Sm Cm crc4 No = Bro Cm on , off Brc Sm
|
||||||
Turn on/off CRC4 superframe mode.
|
|
||||||
(E1 only.)
|
(E1 only.)
|
||||||
|
Turn on/off CRC4 superframe mode.
|
||||||
.It Sm Cm syn No = Bro Cm int , rcv , rcv0 , rcv1 , rcv2 , rcv3 Brc Sm
|
.It Sm Cm syn No = Bro Cm int , rcv , rcv0 , rcv1 , rcv2 , rcv3 Brc Sm
|
||||||
.Bl -tag -width ".Cm rcv3"
|
.Bl -tag -width ".Cm rcv3"
|
||||||
.It Cm int
|
.It Cm int
|
||||||
use an internal clock generator for G703 transmitter
|
Use an internal clock generator for G703 transmitter
|
||||||
(clock master).
|
(clock master).
|
||||||
.It Cm rcv
|
.It Cm rcv
|
||||||
use the G703 receiver data clock as the transmit clock
|
Use the G703 receiver data clock as the transmit clock
|
||||||
(clock slave).
|
(clock slave).
|
||||||
.It Cm rcv0 , rcv1 , rcv2 , rcv3
|
.It Cm rcv0 , rcv1 , rcv2 , rcv3
|
||||||
use the G703 receiver clock of the other channel
|
Use the G703 receiver clock of the other channel
|
||||||
(E1 models only).
|
(E1 models only).
|
||||||
.El
|
.El
|
||||||
.It Cm dir Ns = Ns Ar number
|
.It Cm dir Ns = Ns Ar number
|
||||||
Binds logical channel to the physical channel.
|
|
||||||
(Tau32-PCI, Tau-PCI/2E1 and Tau-PCI/4E1 only.)
|
(Tau32-PCI, Tau-PCI/2E1 and Tau-PCI/4E1 only.)
|
||||||
Using this parameter you could, for example, split E1 physical channel
|
Bind a logical channel to a physical channel.
|
||||||
into several channels.
|
Using this parameter it is possible, for example, to split
|
||||||
|
physical E1 channel into several logical channels.
|
||||||
.It Cm ts Ns = Ns Ar interval
|
.It Cm ts Ns = Ns Ar interval
|
||||||
Set up the list of timeslots to use by the channel (E1 only).
|
(E1 only.)
|
||||||
The
|
Set up the list of timeslots for use by the channel.
|
||||||
timeslots are numbered from 1 to 31, and are separated by comma or minus sign,
|
The timeslots are numbered from 1 to 31,
|
||||||
|
and are separated by a comma or a minus sign,
|
||||||
giving an interval.
|
giving an interval.
|
||||||
For example:
|
Example:
|
||||||
.Dq Li ts=1-3,5,17 .
|
.Dq Li ts=1-3,5,17 .
|
||||||
.It Cm pass Ns = Ns Ar interval
|
.It Cm pass Ns = Ns Ar interval
|
||||||
|
(Tau/E1 only.)
|
||||||
Set up the list of timeslots, translated to the E1 subchannel in
|
Set up the list of timeslots, translated to the E1 subchannel in
|
||||||
.Cm cfg Ns = Ns Cm B
|
.Cm cfg Ns = Ns Cm B
|
||||||
and
|
and
|
||||||
.Cm cfg Ns = Ns Cm C
|
.Cm cfg Ns = Ns Cm C
|
||||||
configurations.
|
configurations.
|
||||||
(Tau/E1 only.)
|
|
||||||
.It Sm Cm debug No = Bro Cm 0 , 1 , 2 Brc Sm
|
.It Sm Cm debug No = Bro Cm 0 , 1 , 2 Brc Sm
|
||||||
Turn on/off debug messages.
|
Turn on/off debug messages.
|
||||||
.Bl -tag -width 2n
|
.Bl -tag -width 2n
|
||||||
.It Cm 0
|
.It Cm 0
|
||||||
turn off debug messages.
|
Turn debug messages off.
|
||||||
.It Cm 1
|
.It Cm 1
|
||||||
turn on debug
|
Turn debug messages on, equivalent to the
|
||||||
messages, equal to the
|
|
||||||
.Cm debug
|
.Cm debug
|
||||||
option to the
|
option of the
|
||||||
.Xr ifconfig 8
|
.Xr ifconfig 8
|
||||||
utility.
|
utility.
|
||||||
.It Cm 2
|
.It Cm 2
|
||||||
high intensive debug message, developers only.
|
High intensive debug messages, for developers only.
|
||||||
.El
|
.El
|
||||||
.El
|
.El
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Sh EXAMPLES
|
.Sh EXAMPLES
|
||||||
Set up the channel 1 for use with the HDSL modem or any other
|
Set up channel 1 for use with the HDSL modem or any other
|
||||||
synchronous leased-line modem, and PPP/HDLC protocol (for Sigma):
|
synchronous leased-line modem, and PPP/HDLC protocol (for Sigma):
|
||||||
.Bd -literal -offset indent
|
.Bd -literal -offset indent
|
||||||
sconfig cx1 ppp extclock
|
sconfig cx1 ppp extclock
|
||||||
ifconfig cx1 158.250.244.2 158.250.244.1 up
|
ifconfig cx1 158.250.244.2 158.250.244.1 up
|
||||||
.Ed
|
.Ed
|
||||||
.Pp
|
.Pp
|
||||||
Set up the channel 0 of Tau/E1 for use with the Cisco protocol
|
Set up channel 0 of Tau/E1 for use with the Cisco protocol
|
||||||
over E1 link, with the single virtual connection.
|
over the E1 link, with a single virtual connection.
|
||||||
The DLCI number is detected automatically.
|
The DLCI number is detected automatically.
|
||||||
Use timeslots 1-10:
|
Use timeslots 1-10:
|
||||||
.Bd -literal -offset indent
|
.Bd -literal -offset indent
|
||||||
@ -414,14 +442,14 @@ sconfig ct0 cisco ts=1-10
|
|||||||
ifconfig ct0 158.250.244.2 158.250.244.1 up
|
ifconfig ct0 158.250.244.2 158.250.244.1 up
|
||||||
.Ed
|
.Ed
|
||||||
.Pp
|
.Pp
|
||||||
Set up the channel 0 for the synchronous null-modem link to the nearby computer,
|
Set up channel 0 for the synchronous null-modem link to the nearby computer,
|
||||||
internal clock source, 256000 bits/sec, protocol Cisco/HDLC (for Tau):
|
internal clock source, 256000 bits/sec, protocol Cisco/HDLC (for Tau):
|
||||||
.Bd -literal -offset indent
|
.Bd -literal -offset indent
|
||||||
sconfig ct0 cisco 256000
|
sconfig ct0 cisco 256000
|
||||||
ifconfig ct0 200.1.1.1 200.1.1.2 up
|
ifconfig ct0 200.1.1.1 200.1.1.2 up
|
||||||
.Ed
|
.Ed
|
||||||
.Pp
|
.Pp
|
||||||
Set up the channel 1 for the leased line link using data-only
|
Set up channel 1 for the leased line link using the data-only
|
||||||
null-modem cable (or modems like Zelax+ M115).
|
null-modem cable (or modems like Zelax+ M115).
|
||||||
Synchronous DPLL mode, 128000
|
Synchronous DPLL mode, 128000
|
||||||
bits/sec, protocol PPP/HDLC, NRZI encoding (for Sigma):
|
bits/sec, protocol PPP/HDLC, NRZI encoding (for Sigma):
|
||||||
@ -431,56 +459,59 @@ ifconfig cx1 158.250.244.2 158.250.244.1 up
|
|||||||
.Ed
|
.Ed
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Sh DIAGNOSTICS
|
.Sh DIAGNOSTICS
|
||||||
This section contains description of abbreviations used by
|
This section contains a description of abbreviations used by
|
||||||
.Nm
|
.Nm
|
||||||
while displaying various statistics.
|
while displaying various statistics.
|
||||||
For description of options connected with
|
For a description of options related to
|
||||||
statistics see above.
|
statistics, please see above.
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Ss Statistics
|
.Ss Statistics
|
||||||
When running, the driver gathers the statistics about the channels, which
|
When running, the driver gathers statistics about the channels, which
|
||||||
could be accessed via the
|
can be accessed using the
|
||||||
.Nm
|
.Nm
|
||||||
utility or by
|
utility,
|
||||||
|
or through the
|
||||||
.Xr ioctl 2
|
.Xr ioctl 2
|
||||||
call
|
call
|
||||||
.Dv SERIAL_GETSTAT .
|
.Dv SERIAL_GETSTAT .
|
||||||
.Bl -tag -width indent
|
.Pp
|
||||||
|
.Bl -tag -width indent -compact
|
||||||
.It Va Rintr
|
.It Va Rintr
|
||||||
The total number of receive interrupts.
|
Total number of receive interrupts.
|
||||||
.It Va Tintr
|
.It Va Tintr
|
||||||
The total number of transmit interrupts.
|
Total number of transmit interrupts.
|
||||||
.It Va Mintr
|
.It Va Mintr
|
||||||
The total number of modem interrupts.
|
Total number of modem interrupts.
|
||||||
.It Va Ibytes
|
.It Va Ibytes
|
||||||
The total bytes received.
|
Total bytes received.
|
||||||
.It Va Ipkts
|
.It Va Ipkts
|
||||||
The total packets received (for HDLC mode).
|
Total packets received (for HDLC mode).
|
||||||
.It Va Ierrs
|
.It Va Ierrs
|
||||||
The number of receive errors.
|
Number of receive errors.
|
||||||
.It Va Obytes
|
.It Va Obytes
|
||||||
The total bytes transmitted.
|
Total bytes transmitted.
|
||||||
.It Va Opkts
|
.It Va Opkts
|
||||||
The total packets transmitted (for HDLC mode).
|
Total packets transmitted (for HDLC mode).
|
||||||
.It Va Oerrs
|
.It Va Oerrs
|
||||||
The number of transmit errors.
|
Number of transmit errors.
|
||||||
.El
|
.El
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Ss E1/G.703 Statistics
|
.Ss E1/G.703 Statistics
|
||||||
For E1 and G.703 channels the SNMP-compatible statistics data are gathered
|
For E1 and G.703 channels, the SNMP-compatible statistics data are gathered
|
||||||
(see RFC 1406).
|
(see RFC 1406).
|
||||||
It could be accessed via the
|
It can be accessed using the
|
||||||
.Nm
|
.Nm
|
||||||
utility or by
|
utility,
|
||||||
|
or through the
|
||||||
.Xr ioctl 2
|
.Xr ioctl 2
|
||||||
call
|
call
|
||||||
.Dv SERIAL_GETESTAT .
|
.Dv SERIAL_GETESTAT .
|
||||||
.Bl -tag -width indent
|
.Bl -tag -width ".Va RCRC Pq Va rcrce"
|
||||||
.It Va Unav Pq Va uas
|
.It Va Unav Pq Va uas
|
||||||
Unavailable seconds - receiving all ones, or loss of carrier, or loss of
|
Unavailable seconds: receiving all ones, loss of carrier, or loss of
|
||||||
signal.
|
signal.
|
||||||
.It Va Degr Pq Va dm
|
.It Va Degr Pq Va dm
|
||||||
Degraded minutes - having error rate more than 10e-6, not counting unavailable
|
Degraded minutes: having error rate more than 10E-6, not counting unavailable
|
||||||
and severely errored seconds.
|
and severely errored seconds.
|
||||||
.It Va Bpv Pq Va bpv
|
.It Va Bpv Pq Va bpv
|
||||||
HDB3 bipolar violation errors.
|
HDB3 bipolar violation errors.
|
||||||
@ -491,29 +522,30 @@ CRC4 errors (E1).
|
|||||||
.It Va RCRC Pq Va rcrce
|
.It Va RCRC Pq Va rcrce
|
||||||
Remote CRC4 errors: E-bit counter (E1).
|
Remote CRC4 errors: E-bit counter (E1).
|
||||||
.It Va Err Pq Va es
|
.It Va Err Pq Va es
|
||||||
Errored seconds - any framing errors, or out of frame sync, or any slip events.
|
Errored seconds: any framing errors, or out of frame sync, or any slip events.
|
||||||
.It Va Lerr Pq Va les
|
.It Va Lerr Pq Va les
|
||||||
Line errored seconds - any BPV.
|
Line errored seconds: any BPV.
|
||||||
.It Va Sev Pq Va ses
|
.It Va Sev Pq Va ses
|
||||||
Severely errored seconds - 832 or more framing errors, or 2048 or more bipolar
|
Severely errored seconds: 832 or more framing errors, or 2048 or more bipolar
|
||||||
violations.
|
violations.
|
||||||
.It Va Bur Pq Va bes
|
.It Va Bur Pq Va bes
|
||||||
Bursty errored seconds - more than 1 framing error, but not severely errored.
|
Bursty errored seconds: more than 1 framing error, but not severely errored.
|
||||||
.It Va Oof Pq Va oofs
|
.It Va Oof Pq Va oofs
|
||||||
Severely errored framing seconds - out of frame sync.
|
Severely errored framing seconds: out of frame sync.
|
||||||
.It Va Slp Pq Va css
|
.It Va Slp Pq Va css
|
||||||
Controlled slip second \[em] any slip buffer overflow or underflow.
|
Controlled slip seconds: any slip buffer overflow or underflow.
|
||||||
.El
|
.El
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Ss E1/G.703 Status
|
.Ss E1/G.703 Status
|
||||||
The
|
The
|
||||||
.Nm
|
.Nm
|
||||||
utility also prints the E1/G.703 channel status.
|
utility also prints the E1/G.703 channel status.
|
||||||
The status could have the
|
The status can have the
|
||||||
following values (nonexclusive):
|
following values (non-exclusive):
|
||||||
.Bl -tag -width indent
|
.Pp
|
||||||
|
.Bl -tag -width ".Li FARLOMF" -compact
|
||||||
.It Li Ok
|
.It Li Ok
|
||||||
The channel is in valid state, synchronized.
|
The channel is in a valid state, synchronized.
|
||||||
.It Li LOS
|
.It Li LOS
|
||||||
Loss of sync.
|
Loss of sync.
|
||||||
.It Li AIS
|
.It Li AIS
|
||||||
@ -525,7 +557,7 @@ Loss of multiframing (E1 only).
|
|||||||
.It Li FARLOF
|
.It Li FARLOF
|
||||||
Receiving remote alarm (E1 only).
|
Receiving remote alarm (E1 only).
|
||||||
.It Li AIS16
|
.It Li AIS16
|
||||||
Receiving all ones in timeslot 16 (E1 only).
|
Receiving all ones in the timeslot 16 (E1 only).
|
||||||
.It Li FARLOMF
|
.It Li FARLOMF
|
||||||
Receiving distant multiframe alarm (E1 only).
|
Receiving distant multiframe alarm (E1 only).
|
||||||
.It Li TSTREQ
|
.It Li TSTREQ
|
||||||
@ -543,33 +575,33 @@ Test error (G.703 only).
|
|||||||
.Xr spppconrol 8
|
.Xr spppconrol 8
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Sh HISTORY
|
.Sh HISTORY
|
||||||
This utility is a replacement of utilities
|
This utility is a replacement for the
|
||||||
.Nm cxconfig
|
.Nm cxconfig
|
||||||
and
|
and
|
||||||
.Nm ctconfig
|
.Nm ctconfig
|
||||||
that was used in past with
|
utilities that were used in the past with
|
||||||
.Fx
|
.Fx
|
||||||
drivers.
|
drivers.
|
||||||
Those two utilities and the present
|
Those two utilities and
|
||||||
utility are not compatible.
|
.Nm
|
||||||
And therefore all scripts should be rewritten.
|
are not compatible,
|
||||||
More over,
|
and therefore all scripts using them have to be rewritten.
|
||||||
|
Moreover,
|
||||||
.Tn Linux
|
.Tn Linux
|
||||||
and
|
and
|
||||||
.Fx
|
.Fx
|
||||||
version of present utility not fully compatible.
|
versions of the
|
||||||
|
.Nm
|
||||||
|
utility are not fully compatible.
|
||||||
|
.\"--------------------------------------------------------------
|
||||||
|
.Sh AUTHORS
|
||||||
|
.An Cronyx Engineering Aq info@cronyx.ru
|
||||||
|
.Pp
|
||||||
|
.Pa http://www.cronyx.ru
|
||||||
.\"--------------------------------------------------------------
|
.\"--------------------------------------------------------------
|
||||||
.Sh BUGS
|
.Sh BUGS
|
||||||
All software produced by Cronyx Engineering is thoroughly tested.
|
All software produced by Cronyx Engineering is thoroughly tested.
|
||||||
But
|
But as created by a man, it can contain some bugs.
|
||||||
as created by the man it can contain some bugs.
|
If you have caught one, try to localize it and send an email with the
|
||||||
If you have caught one, try to localize it and send a letter with description
|
description of the bug, and all operations that you have done.
|
||||||
of this bug and all operation that you have done.
|
We will try to reproduce the error and fix it.
|
||||||
We will try to reproduce
|
|
||||||
an error and fix it.
|
|
||||||
.\"--------------------------------------------------------------
|
|
||||||
.Sh CONTACT
|
|
||||||
E-mail:
|
|
||||||
.Aq info@cronyx.ru
|
|
||||||
.Pp
|
|
||||||
.Pa http://www.cronyx.ru
|
|
||||||
|
Loading…
x
Reference in New Issue
Block a user