Some BMCs support power cycling the chassis via the chassis control
command 2 subcommand 2 (ipmitool called it 'chassis power cycle'). If
the BMC supports the chassis device, register a shutdown_final handler
that sends the power cycle command if request and waits up to 10s for
it to take effect. To minimize stack strain, we preallocate a ipmi
request in the softc. At the moment, we're verbose about what we're
doing.
Sponsored by: Netflix
config info. from device.hints. Some machines have ipmi controllers
that do not have attachment info in either PCI, SMBIOS or ACPI.
This idea was hacked together by me and then done properly by
jhb.
Submitted by: jhb
Reviewed by: jhb (man page)
Approved by: re (Ken Smith)
MFC after: 1 week
to work with ipmitools. It works with other tools that have an OpenIPMI
driver interface. The port will need to get updated to used this.
I have not implemented the IPMB mode yet so ioctl's for that don't
really do much otherwise it should work like the OpenIPMI version.
The ipmi.h definitions was derived from the ipmitool header file.
The bus attachments are done for smbios and pci/smbios. Differences
in bus probe order for modules/static are delt with. ACPI attachment
should be done.
This drivers registers with the watchdod(4) interface
Work to do:
- BT interface
- IPMB mode
This has been tested on Dell PE2850, PE2650 & PE850 with i386 & amd64
kernel.
I will link this into the build on next week.
Tom Rhodes, helped me with the man page.
Sponsored by: IronPort Systems Inc.
Inspired from: ipmitool & Linux