Commit Graph

58 Commits

Author SHA1 Message Date
imp
f65f3ca610 Remove dead code (comma is either 0 or 1 for sure, no need to test).
Close /dev/pci when we're done with it.

CID: 1007450, 1007449, 1008615, 1008614
2018-01-05 07:29:02 +00:00
scottl
a0bc5f59cc Add constants and descriptions for some new PCI class definitions 2017-03-13 07:45:15 +00:00
cem
a8f54ee656 pciconf(8): Replace an assert with errx
The condition can be hit with simple user input, so it isn't an invariant.
Just error out.

PR:		217003
Reported by:	Vladislav V. Prodan <admin at support.od.ua>
Sponsored by:	Dell EMC Isilon
2017-02-11 18:04:43 +00:00
cem
d6b83981c4 pciconf(8): Reallow trailing colon in selectors
Reallow device selectors to have a trailing colon, as documented in the
manual page.  This was broken along with some unrelated cleanups in
r295806.

PR:		215979
Reported by:	David Boyd <David.Boyd49 at twc.com>
Sponsored by:	Dell EMC Isilon
2017-01-12 00:34:37 +00:00
mav
50b1df2a7c Add names for some DASP devices.
Submitted by:	Dmitry Luhtionov <dmitryluhtionov@gmail.com>
MFC after:	1 week
2016-10-21 15:23:54 +00:00
se
73c7c751cd Fix possible out-of-bounds access detected by Ulrich Spörleins "scan-build".
Some invalid PCI device selectors could cause read access to an initialized
variable next to the array (local loop index variable).

While here, the parser has been made more strict with regard to the syntax
of PCI device selectors as documented in the man-page. E.g. "pci:" used to
be interpreted as "pci0:0".

MFC after:	3 days
2016-02-19 14:01:35 +00:00
se
4afdb85262 Use __unused instead of casting to void to silence the unused parameter
warning.

Fix the indentation of 2 lines to conform with the style of this file.

Submitted by:	jhb
2016-02-18 20:20:36 +00:00
se
94a9d119b9 Make WARNS=6 safe.
Tested with Clang 3.7.1, GCC 4.2.1 and GCC 4.8.5 on amd64.
2016-02-18 15:23:25 +00:00
jhb
4647004788 Add a new -B flag for use with list mode (-l) that lists details about
bridges.  Currently this includes information about what resources a
bridge decodes on the upstream side for use by downstream devices including
bus numbers, I/O port resources, and memory resources.  Windows and bus
ranges are enumerated for both PCI-PCI bridges and PCI-CardBus bridges.

To simplify the implementation, all enumeration is done by reading the
appropriate config space registers directly rather than querying the
bridge driver in the kernel via new ioctls.  This does result in a few
limitations.

First, an unimplemented window in a PCI-PCI bridge cannot be accurately
detected as accurate detection requires writing to the window base
register.  That is not safe for pciconf(8).  Instead, this assumes that
any window where both the base and limit read as all zeroes is
unimplemented.

Second, the PCI-PCI bridge driver in a tree has a few quirks for
PCI-PCI bridges that use subtractive decoding but do not indicate that
via the progif config register.  The list of quirks is duplicated in
pciconf's source.

Reviewed by:	imp
MFC after:	2 weeks
Differential Revision:	https://reviews.freebsd.org/D4171
2015-11-23 23:48:07 +00:00
bapt
50ceb9f7c2 Prefer pciids database from ports if present
Given the pciids database on ports is updated more often than the one in base
prefer this version if present, otherwise read the one from base.

MFC after:	1 week
Relnotes:	yes
Differential Revision:	https://reviews.freebsd.org/D3391
2015-09-06 20:05:29 +00:00
rstone
b7fc2d31bd Teach pciconf how to dump out SR-IOV capability
Differential Revision:	https://reviews.freebsd.org/D1639
Reviewed by:		jhb
MFC after:		1 month
Sponsored by:		Sandvine Inc.
2015-03-01 00:59:35 +00:00
dim
51dfb55a00 Fix the following clang 3.6.0 warnings in pciconf:
usr.sbin/pciconf/pciconf.c:237:12: error: address of array 'p->pd_name' will
always evaluate to 'true' [-Werror,-Wpointer-bool-conversion]
                            (p->pd_name && *p->pd_name) ? p->pd_name :
                             ~~~^~~~~~~ ~~
usr.sbin/pciconf/pciconf.c:239:12: error: address of array 'p->pd_name' will
always evaluate to 'true' [-Werror,-Wpointer-bool-conversion]
                            (p->pd_name && *p->pd_name) ? (int)p->pd_unit :
                             ~~~^~~~~~~ ~~

The pd_name field of struct pci_conf is an array, so it can never be null.
Remove the unnecessary check.
2015-01-28 21:21:35 +00:00
markj
6094cae3ca Fix some buglets in the error-handling of getdevice(). In particular, report
an error if the argument to pciconf -a doesn't have a unit number, rather
than triggering an assertion failure.

PR:		194506
Reported by:	Anthony Cornehl <accornehl@gmail.com>
Sponsored by:	EMC / Isilon Storage Division
2014-10-22 23:35:56 +00:00
mav
d4d9cd2fe3 Add IOMMU PCI subclass, found on Tyan S8236 motherboard.
Submitted by:	Dmitry Luhtionov <dmitryluhtionov@gmail.com>
MFC after:	2 weeks
2014-05-20 14:39:22 +00:00
jhb
69c2b2b5df Add support for displaying VPD for PCI devices via pciconf.
- Store the length of each read-only VPD value since not all values are
  guaranteed to be ASCII values (though most are).
- Add a new pciio ioctl to fetch VPD for a single PCI device.  The values
  are returned as a list of variable length records, one for the device
  name and each keyword.
- Add a new -V flag to pciconf's list mode which displays VPD data for
  each device.

MFC after:	1 week
2014-01-20 20:56:09 +00:00
jhb
ba5bbb1d2a - Allow PCI devices that are attached to a driver to be identified by their
device name instead of just the selector.
- Accept an optional device argument to -l to restrict the output to only
  listing details about a single device.  This is mostly useful in
  conjunction with other flags like -e or -c to allow a user to query
  details about a single device.

MFC after:	1 week
2014-01-20 15:51:02 +00:00
neel
329d8f638f Use the entire 64 bits of 'bar.pbi_length' when printing the bar size.
This allows bar sizes greater than or equal to 4GB to be displayed correctly.
2013-02-10 19:35:40 +00:00
gavin
9f412b9646 The correct generic term for PCIS_STORAGE_NVM is "NVM" not "NVM Express".
Submitted by:	jimharris
MFC after:	6 days
2012-09-20 08:30:17 +00:00
gavin
7d7784d2dd Recognise NVM Express devices and pretty-print their name.
MFC after:	1 week
2012-09-19 18:22:14 +00:00
jhb
c0cab82568 Add a new -e flag to pciconf(8)'s list mode to display PCI error details.
Currently this dumps the status of any error bits in the PCI status register
and PCI-express device status register.  It also lists any errors indicated
by version 1 of PCI-express Advanced Error Reporting (AER).

MFC after:	1 week
2012-06-01 18:33:40 +00:00
uqs
415a3a9b96 Spelling fixes for usr.sbin/ 2011-12-30 10:58:14 +00:00
jhb
bf83c54a8b Simplify chkattached(). The PCIOCATTACHED ioctl only needs the pi_sel
field populated, it ignores the rest of the 'pci_sel' structure.

MFC after:	1 week
2010-09-08 18:18:01 +00:00
jhb
fafb6ced88 - Add a new ioctl to /dev/pci to fetch details on an individual BAR of a
device.  The details include the current value of the BAR (including all
  the flag bits and the current base address), its length, and whether or not
  it is enabled.  Since this operation is not invasive, non-root users are
  allowed to use it (unlike manual config register access which requires
  root).  The intention is that userland apps (such as Xorg) will use this
  interface rather than dangerously frobbing the BARs from userland to
  obtain this information.
- Add a new sub-mode to the 'list' mode of pciconf.  The -b flag when used
  with -l will now list all the active BARs for each device.

MFC after:	1 month
2009-02-02 19:54:16 +00:00
mav
95caf1de4f Add ADMA, SATA and SAS mass storage subclasses. 2008-11-13 19:49:16 +00:00
mav
ee74955c75 Add HDA multimedia subclass. 2008-10-21 21:55:38 +00:00
mav
8a975c2c68 Add "SD host controller" subclass name. 2008-10-21 20:57:21 +00:00
imp
88c5e9e192 style nit: indent continuation lines correctly, use style(9) style
if() statement.
2008-09-03 07:08:22 +00:00
imp
cfa9a2ed0e minor style(9) police: sort getopt options alphabetically. The
semi-logical segregation of 'b' and 'h' doesn't seem to make sense and
makes it harder to read.
2008-09-03 07:03:38 +00:00
se
c78f419e4c Make selector parsing accept the dot "." as an alternative selector
with identical meaning as the colon ":". This is to support a syntax
that is more similar to a PCI device specification in the device hints
file. The selector is not fully compatible with the specification in
the hints file, since entries in that file use a different prefix,
which needs to be added to the getsel() routine, if full support of
that syntax is found to be desirable.

Approved by:	re (Ken Smith)
2007-10-04 22:27:08 +00:00
se
38b0f76e4a Restore compatibility with version before introduction of PCI domains.
PCI selectors with 2 or 3 elements behave exactly as before (i.e. the
domain is 0 and in the 2 element case, the function is also 0).
The form with 4 selector elements works as in the previous revision
and provides the PCI domain number as the left-most selector element.

This change allows old scripts (which used the 2 or 3 selector element
formats) to be kept. Without this patch, the 3 element form was parsed
as starting with a domain number (and the function was assumed to be 0),
with this patch, the domain is assumed to be 0 (and the last value is
used as the function number).

The man page is updated to describe the new selector semantics.

Approved by:	re (Ken Smith)
2007-10-04 22:18:53 +00:00
marius
d60b8a3096 Make the PCI code aware of PCI domains (aka PCI segments) so we can
support machines having multiple independently numbered PCI domains
and don't support reenumeration without ambiguity amongst the
devices as seen by the OS and represented by PCI location strings.
This includes introducing a function pci_find_dbsf(9) which works
like pci_find_bsf(9) but additionally takes a domain number argument
and limiting pci_find_bsf(9) to only search devices in domain 0 (the
only domain in single-domain systems). Bge(4) and ofw_pcibus(4) are
changed to use pci_find_dbsf(9) instead of pci_find_bsf(9) in order
to no longer report false positives when searching for siblings and
dupe devices in the same domain respectively.
Along with this change the sole host-PCI bridge driver converted to
actually make use of PCI domain support is uninorth(4), the others
continue to use domain 0 only for now and need to be converted as
appropriate later on.
Note that this means that the format of the location strings as used
by pciconf(8) has been changed and that consumers of <sys/pciio.h>
potentially need to be recompiled.

Suggested by:	jhb
Reviewed by:	grehan, jhb, marcel
Approved by:	re (kensmith), jhb (PCI maintainer hat)
2007-09-30 11:05:18 +00:00
jhb
04771e3c14 - Teach pciconf(8) to list the PCI capabilities supported by each device
via a new -c flag to be used with -l.  Some simple parsing code is
  present for the following capabilities: Power Management, AGP, VPD,
  MSI, PCI-X, HyperTransport, Vendor-specific, EHCI Debug Port, PCI-PCI
  bridge subvendor ID, PCI-express, and MSI-X.
- Fix a few warnings in pciconf.c.
- Update some cruft in pciconf(8):
  - PCI 2.1 is no longer a revolutionary standard, and subvendor ID's are
    fairly common at this point, so reflect that.
  - Header type 2 is used for PCI-CardBus bridges.
  - Describe the -v option for -l after completing the basic -l description
    instead of disrupting the flow in the middle.

Reviewed by:	imp (partially)
MFC after:	1 week
2007-02-02 19:54:17 +00:00
des
8b915afa8a Use larger buffers to read lines from the vendor list.
Trim trailing whitespace and comments before parsing, and skip empty lines.
Skip subvendor / subdevice entries (which start with two tab characters).
Change the scanf() format string to match any amount and type of whitespace
between the device ID and the description text.

MFC after:	3 weeks
2005-08-18 11:11:40 +00:00
des
208685f888 Whitespace cleanup. 2005-08-18 11:04:49 +00:00
jmg
7f5bd42003 add some additional pci classes and sub-classes..
Reviewed by:	imp (almost 6 months ago)
2005-03-26 20:31:09 +00:00
imp
34758c4b4e Revert unintended commit that came in with 3rd clause removal 2004-08-07 16:36:46 +00:00
le
51abab44f5 Fix syntax error introduced in the last commit.
Additionally, since this file is written in C and not in Perl,
we need 'continue' instead of 'next'.
2004-08-07 14:37:49 +00:00
imp
9fbed704d5 Per letter dated July 22, 1999 remove 3rd clause of Berkeley derived software
(with permission of addtional copyright holders where appropriate)
2004-08-07 04:28:56 +00:00
rwatson
0d9473dba7 Only a read-only file descriptor is required to implement list_devs()
and list_verbose(), so don't open /dev/pci read-write.  This allows
pciconf -l[v] to work for non-root users, assuming the securelevel is
0 or -1.

Problem experienced by:	William Michael Grim <wgrim@siue.edu>
2003-12-31 19:38:29 +00:00
jmg
21a5088ba4 make pciconf understand it's own output as stated in the manpage.
pciconf -r none8@pci1:12:2: 0x0
now works.

PR:		bin/10312
Submitted by:	Castor Fu
2003-06-20 23:59:25 +00:00
jdp
1db483ab8c Use consistent terminology in the usage message, the man page
synopsis, and the man page description ("selector" vs. "sel" and
"addr" vs. "reg").

Fix the usage message and man page synopsis to show that the "value"
argument is not optional.
2002-09-17 18:10:39 +00:00
sos
673b8cea9c When asked to print bytes (-b option) do that and put 16 on a line. 2002-02-26 10:40:42 +00:00
imp
ce2cd03ba2 Support a range of registers to read.
eg	pciconf -r pci0:10:0 0:0xff
and keep the output of the old singleton the same.

Reviewed by: audit@, dd

MFC after: 10 days
2001-05-31 18:31:43 +00:00
imp
7868dce32d Minor style(9) tweak: if ( instead of if(. 2001-05-31 05:57:49 +00:00
msmith
c860fb6c1b Update for new location of pcireg.h. 2000-12-09 00:07:46 +00:00
msmith
1a43f5bf1c Update to improve handling of verbose PCI vendor/device information.
- Read the database from /usr/share/misc (or wherever else we're pointed)
   rather than compiling it in.
 - Decode the class/subclass fields if requested.
 - Print things in a slightly longer but more readable format.
2000-12-07 10:52:59 +00:00
msmith
df7eda4f94 Add support for decoding the PCI vendor and device ID registers. Add a
database of about 1400 vendors and 2700 devices courtesy of
www.yourvote.com/pci.  We still need to add some more, but this is a good
start.
2000-11-13 12:08:29 +00:00
ken
cdf669dd0c [ repository copy of sys/pci/pci_ioctl.h to sys/sys/pciio.h happened in the
background ]

Rename sys/pci/pci_ioctl.h to sys/sys/pciio.h to make it easier for
userland programs to use this interface.  Reformat the file, and add a
BSD-style copyright to it.

Add a new man page for pci(4).  The PCIOCGETCONF, PCIOCREAD, and PCIOCWRITE
ioctls are documented, but the PCIOCATTACHED ioctl is not documented
because it is not implemented.

Change includes of <pci/pci_ioctl.h> to <sys/pciio.h> or remove them
altogether.  In many cases, pci_ioctl.h was unused.

Reviewed by:	steve
1999-12-08 17:44:04 +00:00
charnier
f0a54e207a .Fn -> .Xr
Do not start warn() message with uppercase.
1999-11-27 16:59:06 +00:00
peter
efabb9ccb1 $Id$ -> $FreeBSD$ 1999-08-28 01:35:59 +00:00