This change also makes alignment and spacing an explicit number rather
than a bunch of spaces.
Reviewed by: mmacy
Requested by: Yuri Pankov <yuripv@yuripv.net>
The objdir is temporary, and the current example points to GENERIC.
Instead point to the installed location of the debug symbols that are
supposed to match the kernel you are using.
PR: 223993
Submitted by: Trond.Endrestol@ximalas.info
I'm not quite sure why this wasn't caught before. Most likely due to
some generated file not being properly cleaned.
Fix build by just hiding the warnings that `-i` was supposed to fix.
Tested with clang, gcc9, gcc7
match the name of this capability. It was added recently and is not merged
to stable branch, so I hope it is not too late to change the name.
Reviewed by: kib
Differential Revision: https://reviews.freebsd.org/D15475
Perhaps RB_MUTE could mute user startup (rc) output as well, but right
now it mutes only kernel console output, so make the documentation match
reality.
PR: 228193
Sponsored by: The FreeBSD Foundation
Previously gpart's man page listed some command options in prose, and
some in table form, which made it more difficult to use as a reference.
Reviewed by: bcr
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D15135
Alphabetical order, uppercase before lowercase for each letter and with
no regard to whether an option takes an argument.
Sponsored by: The FreeBSD Foundation
Change uint8_t type of opcode argument to int in the print_opcode()
function. Use negative value to print the rest of opcodes, because
zero value is O_NOP, and it can't be uses for this purpose.
Reported by: lev
MFC after: 1 week
If the 'n' flag is provided the provided key number will be used to
decrypt device. This can be used combined with dryrun to verify if the key
is set correctly. This can be also used to determine which key slot we want to
change on already attached device.
Reviewed by: allanjude
Differential Revision: https://reviews.freebsd.org/D15309
'n' is used in other commands to define the key index.
We should be consistent with that.
'C' option is used by patch(1) to perform dryrun so lets use that.
Reviewed by: allanjude
Differential Revision: https://reviews.freebsd.org/D15308
Report the NVMe spec, number of lanes (and max) as well as the PCIe
generation we're negotiated at (and max) for the camcontrol rate
command.
Reviewed by: scottl (the output, not the code)
Sponsored by: Netflix
o Modify ipfw(8) to be able set any prefix6 not just Well-Known,
and also show configured prefix6;
o relocate some definitions and macros into proper place;
o convert nat64_debug and nat64_allow_private variables to be
VNET-compatible;
o add struct nat64_config that keeps generic configuration needed
to NAT64 code;
o add nat64_check_prefix6() function to check validness of specified
by user IPv6 prefix according to RFC6052;
o use nat64_check_private_ip4() and nat64_embed_ip4() functions
instead of nat64_get_ip4() and nat64_set_ip4() macros. This allows
to use any configured IPv6 prefixes that are allowed by RFC6052;
o introduce NAT64_WKPFX flag, that is set when IPv6 prefix is
Well-Known IPv6 prefix. It is used to reduce overhead to check this;
o modify nat64lsn_cfg and nat64stl_cfg structures to use nat64_config
structure. And respectivelly modify the rest of code;
o remove now unused ro argument from nat64_output() function;
o remove __FreeBSD_version ifdef, NAT64 was not merged to older versions;
o add commented -DIPFIREWALL_NAT64_DIRECT_OUTPUT flag to module's Makefile
as example.
Obtained from: Yandex LLC
MFC after: 1 month
Sponsored by: Yandex LLC
A new usage is added so that parameters for netdump may be specified.
Specifically, one configures an interface for netdump with:
# dumpon -c <client IP> -s <server IP> [-g <gateway IP>] <iface name>
Reviewed by: bdrewery, cem (earlier versions), sbruno
MFC after: 1 month
Sponsored by: Dell EMC Isilon
Differential Revision: https://reviews.freebsd.org/D15254
This allows create/delete/attach/detach namespaces on new NVMe controllers.
This is only a first user-level part of the bigger change set. Kernel part
required to detect and handle the configuration changes without reboot is
completely independent and will be added separately.
Submitted by: Matt Williams <mffbsdw@gmail.com> (original version)
Differential Revision: https://reviews.freebsd.org/D11399
This can happen when the fsinfo signature is invalid, and the
user have choose to fix it, in which case the code would return
FSBOOTMOD (not FSOK but not FSFATAL either).
All other (fatal) cases would return FSFATAL.
Obtained from: Android Open Source Project
Obtained from: d8775a29ea
MFC after: 2 weeks
On reload we used to first flush everything, including the list of skipped
interfaces. This can lead to termination of these connections if they send
packets before the new configuration is applied.
Note that this doesn't currently happen on 12 or 11, because of special EACCES
handling introduced in r315514. This special behaviour in tcp_output() may
change, hence the fix in pfctl.
PR: 214613
This fixes media display for 802.11 wireless devices.
Software outside the base system that uses these media types and
defines should use #ifdef IFM_FDDI or IFM_TOKEN to include or remove
support.
Reported by: zeising
Reviewed by: emaste, kib, zeising
Tested by: zeising
Sponsored by: DARPA, AFRL
Differential Revision: https://reviews.freebsd.org/D15170
- Warn, don't exit, when SIOCSLAGGPORT returns an error.
When we exit with an error during lagg creation, a single
failed NIC (which no longer attaches) can prevent lagg
creation and other configuration, such as adding an IPv4
address, and thus leave a machine unreachable.
- Preserve non-EEXISTS errors for exit status from SIOCSLAGGPORT,
in case scripts are looking for it. Hopefully this can be
extended if other parts of ifconfig can allow a "soft" failure.
- Improve the warning message to mention what lagg and what
member are problematic.
Reviewed by: jtl, glebius
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D15046
After r331668 handling of F_NOT flag done in one place by
print_instruction() function. Also remove unused argument from
print_ip[6]() functions.
MFC after: 1 week
Defines in net/if_media.h remain in case code copied from ifconfig is in
use elsewere (supporting non-existant media type is harmless).
Reviewed by: kib, jhb
Sponsored by: DARPA, AFRL
Differential Revision: https://reviews.freebsd.org/D15017
This will allow us to verify if passphrase and key is valid without
decrypting whole device.
Reviewed by: cem@, allanjude@
Differential Revision: https://reviews.freebsd.org/D15000
Introduce show_state structure to keep information about printed opcodes.
Split show_static_rule() function into several smaller functions. Make
parsing and printing opcodes into several passes. Each printed opcode
is marked in show_state structure and will be skipped in next passes.
Now show_static_rule() function is simple, it just prints each part
of rule separately: action, modifiers, proto, src and dst addresses,
options. The main goal of this change is avoiding occurrence of wrong
result of `ifpw show` command, that can not be parsed by ipfw(8).
Also now it is possible to make some simple static optimizations
by reordering of opcodes in the rule.
PR: 222705
Discussed with: melifaro
MFC after: 2 weeks
Sponsored by: Yandex LLC
According to 802.1Q-2014, VLAN tagged packets with VLAN id 0 should be
considered as untagged, and only PCP and DEI values from the VLAN tag
are meaningful. See for instance
https://www.cisco.com/c/en/us/td/docs/switches/connectedgrid/cg-switch-sw-master/software/configuration/guide/vlan0/b_vlan_0.html.
Make it possible to specify PCP value for outgoing packets on an
ethernet interface. When PCP is supplied, the tag is appended, VLAN
id set to 0, and PCP is filled by the supplied value. The code to do
VLAN tag encapsulation is refactored from the if_vlan.c and moved into
if_ethersubr.c.
Drivers might have issues with filtering VID 0 packets on
receive. This bug should be fixed for each driver.
Reviewed by: ae (previous version), hselasky, melifaro
Sponsored by: Mellanox Technologies
MFC after: 2 weeks
Differential revision: https://reviews.freebsd.org/D14702
If the operation is not an update, if neither r/w nor r/o mode is
explicitly requested, if the error code hints at the possibility of the
media being read-only, and if the fallback is allowed, then we can try
to automatically downgrade to the readonly mode.
This is especially useful for auto-mounting of removable media that
sometimes can happen to be write-protected.
The fallback to r/o is not enabled by default. It can be requested on a
per-mount basis with a new mount option, 'autoro'. Or it can be
globally allowed by setting vfs.default_autoro.
Reviewed by: cem, kib
MFC after: 3 weeks
Relnotes: yes
Differential Revision: https://reviews.freebsd.org/D13361
Followup to r313780. Also prefix ext2's and nandfs's versions with
EXT2_ and NANDFS_.
Reported by: kib
Reviewed by: kib, mckusick
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D9623
It allows to change namespace parameters, such as block size, metadata,
protection information, etc. and/or erase the data.
MFC after: 2 weeks
Sponsored by: iXsystems, Inc.
ip_reass() expects IPv4 packet and will just corrupt any IPv6 packets
that it gets. Until proper IPv6 fragments handling function will be
implemented, pass IPv6 packets to next rule.
PR: 170604
MFC after: 1 week