Foundation copyrights, approved by emaste@. It does not include
files which carry other people's copyrights; if you're one
of those people, feel free to make similar change.
Reviewed by: emaste, imp, gbe (manpages)
Differential Revision: https://reviews.freebsd.org/D26980
Mak the Ethernet PCP codepoint configurable
for L2 local traffic, to allow lower latency for
iSCSI block IO. This addresses the target
side only.
Reviewed by: mav, trasz, bcr
Sponsored by: NetApp, Inc.
Differential Revision: https://reviews.freebsd.org/D26740
Remove quotes around size in the LUN section and change the suffix to 'GB'. The
UCL format does recognize 'G' on its own, which uses a base 10 multiplier where
'GB' uses a 2 power multiplier.
Document the difference between valid suffixes when using ctl.conf(5) in the
general syntax form or in UCL format.
Reviewed by: kevans, mav
Approved by: kevans (mentor)
Differential Revision: https://reviews.freebsd.org/D26716
Repeating the default WARNS here makes it slightly more difficult to
experiment with default WARNS changes, e.g. if we did something absolutely
bananas and introduced a WARNS=7 and wanted to try lifting the default to
that.
Drop most of them; there is one in the blake2 kernel module, but I suspect
it should be dropped -- the default WARNS in the rest of the build doesn't
currently apply to kernel modules, and I haven't put too much thought into
whether it makes sense to make it so.
In order to prioritize iSCSI traffic across a network,
DSCP can be used. In order not to rely on "ipfw setdscp"
or in-network reclassification, this adds the dscp value
directly to the portal group (where TCP sessions are accepted).
The incoming iSCSI session is first handled by ctld for any
CHAP authentication and the socket is then handed off to the
in-kernel iscsi driver without modification of the socket
parameters. Simply setting up the socket in ctld is sufficient
to keep sending outgoing iSCSI related traffic with the
configured DSCP value.
Reviewed by: mav, trasz
MFC after: 2 weeks
Sponsored by: NetApp, Inc.
Differential Revision: https://reviews.freebsd.org/D26385
from the kernel, but let's try to be on the safe side.
Reviewed by: mav
MFC after: 2 weeks
Sponsored by: NetApp, Inc.
Sponsored by: Klara, Inc.
Differential Revision: https://reviews.freebsd.org/D26246
Before switching to nvlists CTL merged previous and new options, so
any options not passed just kept previous value. Now CTL completely
replaces them, so we must pass everything still relevant.
MFC after: 1 week
Sponsored by: iXsystems, Inc.
ioctl frontend ports.
This revision introduces two changes to CTL:
- Changes the way options are passed to CTL_LUN_REQ and CTL_PORT_REQ ioctls.
Removes ctl_be_arg structure and associated logic and replaces it with
nv(3)-based logic for passing in and out arguments.
- Allows creating multiple ioctl frontend ports using either ctladm(8) or
ctld(8).
New frontend ports are represented by /dev/cam/ctl<pp>.<vp> nodes, eg /dev/cam/ctl5.3.
Those device nodes respond only to CTL_IO ioctl.
New command-line options for ctladm:
# creates new ioctl frontend port with using free pp and vp=0
ctladm port -c
# creates new ioctl frontend port with pp=10 and vp=0
ctladm port -c -O pp=10
# creates new ioctl frontend port with pp=11 and vp=12
ctladm port -c -O pp=11 -O vp=12
# removes port with number 4 (it's a "targ_port" number, not pp number)
ctladm port -r -p 4
New syntax for ctl.conf:
target ... {
port ioctl/<pp>
...
}
target ... {
port ioctl/<pp>/<vp>
...
Note: Most of this work was made by jceel@, thank you.
Submitted by: jceel
Reworked by: myself
Reviewed by: mav (earlier versions and recently during the rework)
Obtained from: FreeNAS and TrueOS
Relnotes: Yes
Sponsored by: iXsystems Inc.
Differential Revision: https://reviews.freebsd.org/D9299
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.
The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
No functional change intended.
From config synthax point of view such portal groups are not incorrect,
but they are useless since can not receive any connection. And since
CTL port resource is very limited, it is good to save it.
MFC after: 2 weeks
The goal of this work is to remove the explicit dependency for ctl(4)
on iscsi(4), so end-users without iscsi(4) support in the kernel can
use ctl(4) for its other functions.
This allows those without iscsi(4) support built into the kernel to use
ctl(4) as a test mechanism. As a sidenote, this was possible around the
10.0-RELEASE period, but made impossible for end-users without iscsi(4)
between 10.0-RELEASE and 11.0-RELEASE.
Automatically load cfiscsi(4) from ctladm(8) and ctld(8) for backwards
compatibility with previously releases. The automatic loading feature is
compiled into the beforementioned tools if MK_ISCSI == yes when building
world.
Add a manpage for cfiscsi(4) and refer to it in ctl(4).
Differential Revision: D10099
MFC after: 2 months
Relnotes: yes
Reviewed by: mav, trasz
Sponsored by: Dell EMC Isilon
If initiator does not negotiate some parameter, it expects one to get
default value, not some unknown remote hardware limit. On the side side,
if some parameter is negotiated, its default value from RFC should not
be used for anything.
Decouple the send and receive limits on the amount of data in a single
iSCSI PDU. MaxRecvDataSegmentLength is declarative, not negotiated, and
is direction-specific so there is no reason for both ends to limit
themselves to the same min(initiator, target) value in both directions.
Allow iSCSI drivers to report their send, receive, first burst, and max
burst limits explicitly instead of using hardcoded values or trying to
derive all of them from the receive limit (which was the only limit
reported by the drivers prior to this change).
Display the send and receive limits separately in the userspace iSCSI
utilities.
Reviewed by: jpaetzel@ (earlier version), trasz@
Sponsored by: Chelsio Communications
Differential Revision: https://reviews.freebsd.org/D7279
The target must reply with the selected value of MaxBurstSize instead of
just echoing back the initiator's offered value.
Reviewed by: mav@
Sponsored by: Chelsio Communications
Differential Revision: https://reviews.freebsd.org/D7278
These are no longer needed after the recent 'beforebuild: depend' changes
and hooking DIRDEPS_BUILD into a subset of FAST_DEPEND which supports
skipping 'make depend'.
Sponsored by: EMC / Isilon Storage Division