Scott Long
33a375b754 Clarify the description string for one of the StrongARM based cards. 2001-08-17 20:59:49 +00:00
Scott Long
f6c4dd3f48 Bugfixes. Close a race and logic bug in the timeout handling, don't call the
interrupt handler from the upper half, etc.  This fixes some serious stability
problems that we were seeing on our production server.  These patches have
been tested for almost 6 months and are a highly recommended MFC candidate.

Reviewed by:	gibbs, merry, msmith
MFC after:	4 days
2001-08-05 06:20:13 +00:00
Scott Long
fadfef893f Fix a couple of copyright issues and an 80 column nit that I missed before 2001-08-05 06:15:00 +00:00
Scott Long
c6eafcf2c5 Reformat for 80 columns. Sorry, but I had to do it. 2001-08-03 00:50:30 +00:00
Mike Smith
0bc88fe1eb Add another Dell 3/Di PCI ID. You'd think they had enough of these
already...
2001-07-22 04:06:36 +00:00
Mike Smith
ed1c82f450 More new Dell PCI IDs.
Submitted by:	"Marty Moll" <martym@arbor.edu>
2001-04-26 01:14:37 +00:00
Mike Smith
71665b0add The PERC 3/Di in the Dell PowerEdge 2250 has a new subdevice ID.
Submitted by:	Chris Csanady <cc@ameslab.gov>
2001-04-26 00:32:02 +00:00
Mark Murray
ed34d0ade2 Turn on interrupt-entropy harvesting for all/any mass storage devices
I could find. I have no doubt missed a couple.

Interrupt entropy harvesting is still conditional on the
kern.random.sys.harvest_interrupt sysctl.
2001-03-01 17:09:09 +00:00
Mike Smith
0b94a66e3f Major bugfix and minor update. This should resolve the current issues
with the driver locking up under load.

 - Restructure so that we use a static pool of commands/FIBs, rather than
   allocating them in clusters.  The cluster allocation just made things
   more complicated, and allowed us to waste more memory in peak load
   situations.
 - Make queueing macros more like my other drivers.  This adds queue stats
   for free.  Add some debugging to take advantage of this.
 - Reimplement the periodic timeout scan.  Kick the interrupt handler
   and the start routine every scan as well, just to be safe.  Track busy
   commands properly.
 - Bring resource cleanup into line with resource allocation.  We should
   now clean up correctly after a failed probe/unload/etc.
 - Try to start new commands when old ones are completed.  We weren't doing
   this before, which could lead to deadlock when the controller was full.
 - Don't try to build a new command if we have found a deferred command.
   This could cause us to lose the deferred command.
 - Use diskerr() to report I/O errors.
 - Don't bail if the AdapterInfo structure is the wrong size.  Some variation
   seems to be normal.  We need to improve our handing of 2.x firmware sets.
 - Improve some comments in an attempt to try to make things clearer.
 - Restructure to avoid some warnings.
2000-12-27 13:14:56 +00:00
Mike Smith
e10f2ee576 Return -10 from the PCI probe to allow room for an updated driver to
override one built into the kernel.
2000-10-28 10:46:30 +00:00
Mike Smith
358637397e A new driver for PCI:SCSI RAID controllers based on the Adaptec FSA
design.  This includes integrated Dell RAID controllers, the Dell
PERC 2/QC and the HP NetRAID-4M.