This option was used in the early days to allow performance measurements
extrapolating the use of SCTP checksum offloading. Since this feature
is now available, get rid of this option.
This also un-breaks the LINT kernel. Thanks to markj@ for making me
aware of the problem.
Mainly focus on files that use BSD 3-Clause license.
The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
Special thanks to Wind River for providing access to "The Duke of
Highlander" tool: an older (2014) run over FreeBSD tree was useful as a
starting point.
o Separate fields of struct socket that belong to listening from
fields that belong to normal dataflow, and unionize them. This
shrinks the structure a bit.
- Take out selinfo's from the socket buffers into the socket. The
first reason is to support braindamaged scenario when a socket is
added to kevent(2) and then listen(2) is cast on it. The second
reason is that there is future plan to make socket buffers pluggable,
so that for a dataflow socket a socket buffer can be changed, and
in this case we also want to keep same selinfos through the lifetime
of a socket.
- Remove struct struct so_accf. Since now listening stuff no longer
affects struct socket size, just move its fields into listening part
of the union.
- Provide sol_upcall field and enforce that so_upcall_set() may be called
only on a dataflow socket, which has buffers, and for listening sockets
provide solisten_upcall_set().
o Remove ACCEPT_LOCK() global.
- Add a mutex to socket, to be used instead of socket buffer lock to lock
fields of struct socket that don't belong to a socket buffer.
- Allow to acquire two socket locks, but the first one must belong to a
listening socket.
- Make soref()/sorele() to use atomic(9). This allows in some situations
to do soref() without owning socket lock. There is place for improvement
here, it is possible to make sorele() also to lock optionally.
- Most protocols aren't touched by this change, except UNIX local sockets.
See below for more information.
o Reduce copy-and-paste in kernel modules that accept connections from
listening sockets: provide function solisten_dequeue(), and use it in
the following modules: ctl(4), iscsi(4), ng_btsocket(4), ng_ksocket(4),
infiniband, rpc.
o UNIX local sockets.
- Removal of ACCEPT_LOCK() global uncovered several races in the UNIX
local sockets. Most races exist around spawning a new socket, when we
are connecting to a local listening socket. To cover them, we need to
hold locks on both PCBs when spawning a third one. This means holding
them across sonewconn(). This creates a LOR between pcb locks and
unp_list_lock.
- To fix the new LOR, abandon the global unp_list_lock in favor of global
unp_link_lock. Indeed, separating these two locks didn't provide us any
extra parralelism in the UNIX sockets.
- Now call into uipc_attach() may happen with unp_link_lock hold if, we
are accepting, or without unp_link_lock in case if we are just creating
a socket.
- Another problem in UNIX sockets is that uipc_close() basicly did nothing
for a listening socket. The vnode remained opened for connections. This
is fixed by removing vnode in uipc_close(). Maybe the right way would be
to do it for all sockets (not only listening), simply move the vnode
teardown from uipc_detach() to uipc_close()?
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D9770
The tools using to generate the sources has been updated and produces
different whitespaces. Commit this seperately to avoid intermixing
these with real code changes.
MFC after: 3 days
directly accessed. Although this will work on some platforms, it can
throw an exception if the pointer is invalid and then panic the kernel.
Add a missing SYSCTL_IN() of "SCTP_BASE_STATS" structure.
MFC after: 3 days
Sponsored by: Mellanox Technologies
eliminiates some warnings when building in userland.
Thanks to Patrick Laimbock for reporting this issue.
Remove also some unnecessary casts.
There should be no functional change.
MFC after: 1 week
NRSACK extension. The default will still be off, since it
it not an RFC (yet).
Changing the sysctl name will be in a separate commit.
MFC after: 1 week
reporting IP-addresses to the peer during the handshake, adding
addresses to the host, reporting the addresses via the sysctl
interface (used by netstat, for example) and reporting the
addresses to the application via socket options.
This issue was reported by Bernd Walter.
MFC after: 3 days
proprietary binary format.
* Add support for a diagnostic information error cause.
The code is sysctlable and the default is 0, which
means it is not sent.
This is joint work with rrs@.
MFC after: 1 week
When exporting to xinpcb, just export the lower
32-bit. Using there also 64-bits will break the
ABI and will be committed separetly.
MFC after: 2 weeks
X-MFC with: 254248
If set to 1, no ABORT is sent back in response to an incoming
INIT. If set to 2, no ABORT is sent back in response to
an out of the blue packet. If set to 0 (the default), ABORTs
are sent.
Discussed with rrs@.
MFC after: 1 month.
* Decouple the path supervision using a separate HB timer per path.
* Add support for potentially failed state.
* Bring back RTO.min to 1 second.
* Accept packets on IP-addresses already announced via an ASCONF
* While there: do some cleanups.
Approved by: re@
MFC after: 2 months.
Some bugs where fixed while doing this:
* ASCONF-ACK messages might use wrong port number when using
IPv6.
* Checking for additional addresses takes the correct address
into account and also does not do more comparisons than
necessary.
This patch is based on one received from bz@ who was
sponsored by The FreeBSD Foundation and iXsystems.
MFC after: 1 week
right mix. Still may need some tweaks but it
appears to almost not give away too much to an
RFC2581 flow, but can really minimize the amount of
buffers used in the net.
MFC after: 3 months
the RTT that a flow will build up in buffers in
transit. It is a slight modification to RFC2581
but is more friendly i.e. less aggressive.
MFC after: 3 months