njl
ffd936fa8c Remove unused variable.
Coverity ID:	548
Found by:	Coverity Prevent
2006-02-21 03:16:58 +00:00
bruno
7f7a28fe5e * fix bst.status. We mark some bits, but forgot to reset all of them
before.  The symptom is that the battery inform us its charge and discharge
  at the same time...

* fix bst.rate to correctly output the (dis)charging rate.  We'll use
  the current average over one minute command and not the at_rate command.
  Note that this method is not correct if the capacity_mode is set, but
  since we don't set it ourself, it is not a problem.

  The at_rate do not give the actual rate but is used to compute the
  estimated time for (dis)charging a battery.  We should actually
  write an estimation of the actual rate using at_rate cmd and then
  perform a read to the various estimators.

Approved by:	njl
MFC after:	2 days
2006-01-12 21:56:37 +00:00
njl
b4b8d998c5 Only copy out the battery status/info if there was no error. 2005-11-24 05:23:56 +00:00
ume
3db092e2ba Cache the result of battery info retrieval from smbat as well
as cmbat.

Reviewed by:	njl
MFC after:	3 days
2005-11-22 03:34:09 +00:00
njl
fb077af79e Import ACPI smart battery support. Newer systems (Acer, mostly) do not
support the CM-battery interface.  Smart batteries can eventually be
supported without ACPI via a separate SMBus interface.  The ACPI interface
uses the embedded controller for reading/writing to the SMBus, and normal
ASL definitions for locating the battery controller (since SMBus can't be
enumerated.)  Also import definitions for the smart battery interface.

This was written by Hans Petter Selasky with minor cleanups from myself.

Submitted by:	Hans Petter Selasky <hselasky / c2i.net>
2005-10-23 00:20:13 +00:00