- after killing all attached providers, all providers are then detached
and operation is repeated for those who were attached,
- we don't want to remove keys for read-only attached providers, we only
want to detach them.
MFC after: 1 week
Now, encryption algorithm is given using '-e' option, not '-a'.
The '-a' option is now used to specify authentication algorithm.
Supported by: Wheel Sp. z o.o. (http://www.wheel.pl)
supported for a moment.
- Don't allow to use -i when no passphrase is given. Now if iterations is
equal to -1 (not set), we know that we should not ask for the passphrase
on boot.
It still doesn't handle situation when one key is protected with
passphrase and the other is not. There is no quick fix for this.
The complete solution will be to make number of iterations a per-key
value. Because this need metadata format change and is only needed for
devices attached on boot, I'll leave it as it is for now.
MFC after: 3 days
- number of read I/O requests,
- number of write I/O requests,
- number of read bytes,
- number of written bytes.
Add 'reset' subcommand for resetting statistics.
value (intmax_t) and boolean (int).
Based on that provide three functions:
- gctl_get_ascii()
- gctl_get_int()
- gctl_get_intmax()
- Hide gctl_get_param() function, as it is only used internally in
subr.c.
- Allow to provide argument name as (fmt, ...).
- Assert geom(8) bugs (missing argument is a geom(8) bug).
- Clean-up and simplify the code by using new functions and assumtions
(no more checking for missing argument).
Tested by: regression tests
ignore "no such file" errors only, which I wanted to do.
Because of this I ignored all other errors on dlopen(3) failure as well,
which isn't good.
Fix this situation by calling access(2) on library file first and ignore
only ENOENT error. This allows to report all the rest of dlopen(3) errors.
MFC after: 3 days
metadata is equal to -1. if we then wanted to attach provider (or change
keys) and forget about '-p' flag it failed on assertion (quite ok, without
assertion it could call PKCS#5v2 with 4294967295 iterations).
Instead of failing on assertion, remind about '-p' flag.
MFC after: 3 days
usage for a subcommand, so no 'usage' function has to be implemented
in class library.
- Bump version number as it breaks ABI, but don't provide backward
compatibility, because there are probably no external consumers of this
geom(8).
This allows to print more precise usage for standard commands and simplify
class libraries a bit.
MFC after: 1 week
warning on 64-bit platforms. Explicitly cast these values to int
to work around this issue, as these values are tend to be small.
Spotted by: ia64 tinderbox
providers.
This prevents from listing geoms like <name>.sync which can be confusing.
It still allows to show details about it by giving its name when listing.
MFC after: 1 week
shared-last-sector problem.
After this change, even if there is more than one provider with the same
last sector, the proper one will be chosen based on its size.
It still doesn't fix the 'c' partition problem (when da0s1 can be confused
with da0s1c) and situation when 'a' partition starts at offset 0
(then da0s1a can be confused with da0s1 and da0s1c). One can use '-h'
option there, when creating device or avoid sharing last sector.
Actually, when providers share the same last sector and their size is equal,
they provide exactly the same data, so the name (da0s1, da0s1a, da0s1c)
isn't important at all.
- Provide backward compatibility.
- Update copyright's year.
MFC after: 1 week
the given providers. Without even one of the configured components there
should be no way to get the secret.
Supported by: WHEEL Sp. z o.o.
http://www.wheel.pl
After this change, when component is disconnected because of an I/O error,
it will not be connected and synchronized automatically, it will be logged
as broken and skipped. Autosynchronization can occur, when component is
disconnected (on orphan event) and connected again - there were no I/O
error, so there is no need to not connected the component, but when there were
writes while it wasn't connected, it will be synchronized.
This fix cases, when component is disconnected because of I/O error and can be
connected again and again.
- Bump version number.
- Implement backward compatibility mechanism. After this change when metadata in
old version is detected, it is automatically upgraded to the new (current)
version.
After this change, when component is disconnected because of an I/O error,
it will not be connected and synchronized automatically, it will be logged
as broken and skipped. Autosynchronization can occur, when component is
disconnected (on orphan event) and connected again - there were no I/O
error, so there is no need to not connected the component, but when there were
writes while it wasn't connected, it will be synchronized.
This fix cases, when component is disconnected because of I/O error and can be
connected again and again.
- Bump version number.
- Add version change history.
- Implement backward compatibility mechanism. After this change when metadata in
old version is detected, it is automatically upgraded to the new (current)
version.