at all (ie reads yield constant values). Display the width as the
difference between max and min so that constant timers have width
zero.
o Get the address of the timer from the XPmTmrBlk field instead of
the V1_PmTmrBlk field. The former is a generic address and can
specify a memory mapped I/O address. Remove <machine/bus_pio.h>
to account for this. The timer is now properly configured on
machines with ACPI v2 tables, whether PIO or MEMIO. Note that
the acpica code converts v1 tables into v2 tables so the address
is always present in XPmTmrBlk.
o Replace the TIMER_READ macro with a call to the read_counter()
function and add a barrier to make sure that we observe proper
ordering of the reads.
* AcpiOsDerivePciId(): finds a bus number, given the slot/func and the
acpi parse tree.
* AcpiOsPredefinedOverride(): use the sysctl hw.acpi.os_name to
override the value for _OS.
Ideas from: takawata, jhb
Reviewed by: takawata, marcel
Tested on: i386, ia64
the list of supported sleep state.
This should help people understand what following message means.
acpi0: AcpiGetSleepTypeData failed - AE_NOT_FOUND
MFC after: 3 days
branches:
Initialize struct cdevsw using C99 sparse initializtion and remove
all initializations to default values.
This patch is automatically generated and has been tested by compiling
LINT with all the fields in struct cdevsw in reverse order on alpha,
sparc64 and i386.
Approved by: re(scottl)
pci busses implement this.
Also minor comment smithing in cardbus. Fix copyright to this year
with my name on it since I've been doing a lot to this file.
Reviewed by: jhb
than hard-coded uids and gids.
Switch the device to a group of wheel instead of operator.
Narrow down the permissions on the device to require root privilege
to manipulate the system power state. It may be that we can broaden
access to the device after review of the access control in ACPI.
Submitted by: kris
Reviewed by: takawata
I/O port range, then we should ignore a resource if it's NOT
a memory range AND NOT an I/O port range.
The OR in the condition caused us to ignore perfectly valid
memory addresses.
While here, remove redundant parenthesis and reindent the
debug print to avoid long lines.
There were no serious problem reports on this in spite of my concern.
To get debug output from acpi_pci_link, just enable bootverbose flag
in usual manner (boot -v).
Approved by: re
to PCI bridge can be read be evaluating the _BBN method of the host to PCI
device. Unfortunately, there appear to be some lazy/ignorant/moronic/
whatever BIOS writers that return 0 for _BBN for all host to PCI bridges in
the system. On a system with a single host to PCI bridge this is not a
problem as the child bus of that single bridge will be bus 0 anyway.
However, on systems with multiple host to PCI bridges and l/i/m/w BIOS
writers this is a major problem resulting in all but the first host to
PCI bridge failing to attach. So, this adds a workaround.
If the _BBN of a host to PCI bridge is zero and pcib0 already exists
and is not us, the we use _ADR to look up our PCI function and slot
(we currently assume we are on bus 0) and use that to call
host_pcib_get_busno() to try and extract our bus number from config
registers on the host to PCI bridge device. If that fails, then we make
an evil assumption that ACPI's _SB_ namespace lays out the host to PCI
bridges in ascending order and use our pcib unit number as our bus
number.
Approved by: re
acpi_cmbat_init_battery() and acpi_cmbat_init_acline() respectively.
Call acpi_cmbat_init_battery() from acpi_cmbat_resume() too just in
case.
This is a workaround for embedded controller operations which is
unstable for about a minute (typically 30 or 40 sec.) at boot time.
state. Instead, use ACPI_STA_PRESENT and ACPI_STA_FUNCTIONAL for it.
In some ACPI BIOS implementations, boot disabled devices don't have
ACPI_STA_ENABLE bit in _STA object.
Also it is not fatal if getting current IRQ of boot disabled devices
is failed in initial state.
And minor fixes.
In that case use proc0's pid to return the thread ID.
- For 4-stable, use the generic swi taskqueue for ACPI events rather than
implementing our own.
Sponsored by: The Weather Channel
This allocate the best IRQ to boot-disable devices (have IRQ 0).
Allocated IRQ will be used for PCI interrupt routing when ACPI is
enabled.
Note that verbose messaging enabled for the time being so that
people can easily notice the strange behavior if it happened.
doesn't give them enough stack to do much before blowing away the pcb.
This adds MI and MD code to allow the allocation of an alternate kstack
who's size can be speficied when calling kthread_create. Passing the
value 0 prevents the alternate kstack from being created. Note that the
ia64 MD code is missing for now, and PowerPC was only partially written
due to the pmap.c being incomplete there.
Though this patch does not modify anything to make use of the alternate
kstack, acpi and usb are good candidates.
Reviewed by: jake, peter, jhb
any machine dependent initialization. This allows the MD code to set the
interrupt routing model so that PCI interrupts are routed correctly when
using an APIC or SAPIC for example.