Commit Graph

121 Commits

Author SHA1 Message Date
bde
4fe2aa11ba Fixed a missing library in DPADD.
Fixed some misformattings.
2000-03-27 18:38:29 +00:00
phk
a6fcf56263 B_READ is gone, check for BIO_READ instead.
Not tested.
2000-03-20 17:12:45 +00:00
grog
d5a01916c2 Remove description of defunct DEBUG_NUMOUTPUT by commenting out.
Describe stop -f to stop when config updates are disabled.

Explain in more detail why Vinum needs its own partition type, and why
you can't make it the c partition.

Implicitly-sanctioned-by:	jkh
2000-03-01 07:22:10 +00:00
grog
cf44ef7326 Add declaration for parityops.
Implicitly-sanctioned-by:	jkh
2000-03-01 07:21:21 +00:00
grog
090cc794ba Increase the time we'll wait for a reviving disk to carry on and not
be marked as stalled, from 1 second to 5 seconds.

Implicitly-sanctioned-by:	jkh
2000-03-01 07:20:32 +00:00
grog
9301681b2f Implement vinum_rebuildparity, which had got forgotten. In the
process, move the body of vinum_rebuildparity and vinum_checkparity to
a new function, parityops.

Implicitly-sanctioned-by:	jkh
2000-03-01 07:19:33 +00:00
grog
72dbae65b9 Add definitions for vinum_raid[45] and checkupdates.
Approved-by:  jkh
2000-02-29 06:22:09 +00:00
grog
726ca37d80 Don't print any error message if we can't open the history file. This
replaces an older attempt to silence vinum(8) when started in
single-user mode.

Add entries for vinum_raid[45].

Replace the preprocessor variable name CDEV_MAJOR with
VINUM_CDEV_MAJOR.

continue_revive: Set the proc title to 'reviving <sdname>' so that it
can be recognized in a ps list.

Approved-by:  jkh
2000-02-29 06:21:38 +00:00
grog
83943ac967 vinum_ldi: Honour the 'recurse' flag and show the subdisks on this
drive if it is set.

vinum_lvi: Change line spacing.  This is still not right.

Change checks for striped or RAID-5 plexes to a macro 'isstriped',
which now also includes RAID-4.

Change checks for RAID-5 plexes to a macro 'isparity', which now also
includes RAID-4.

vinum_lsi: If the subdisk is initializing or reviving, don't wait a
whole second to check whether it's advancing; wait in increments of 50
ms up to 1 second.  This makes for a barely perceptible delay.

Approved-by:  jkh
2000-02-29 06:20:57 +00:00
grog
dfb30d0b63 New function checkupdates: check whether configuration updates are
enabled and print a warning message in varous places if they are not.

Fix typos in comments.

Change some indents to approach style(9).

initvol: If init fails, place the subdisks in a "down" state.

vinum_start(): If we're starting a plex, try doing it directly.  It's
possible that the state of the plex differs from that of the subdisks,
for example if somebody has used 'setupstate'.

New functions vinum_raid4 and vinum_raid5 to create RAID-4 and RAID-5
volumes, analagous to vinum_mirror and vinum_stripe.

vinum_checkparity: Don't try to check the parity of a non-parity plex,
print a rude remark instead.

Approved-by:  jkh
2000-02-29 06:19:42 +00:00
peter
e5f21c38e3 Don't use /dev/vinum/rsd/XXX for init as it doesn't exist any more.
Without this change, you cannot do the required init on a new raid5 volume.

Reviewed by:	grog
Approved by:	jkh
2000-02-06 02:40:22 +00:00
grog
256d6ab5ab make_devices(): Create devices with permissions 640, not 740.
Pointed-out-by:	"Rodney W. Grimes" <freebsd@gndrsh.dnsmgr.net>
2000-01-05 23:56:33 +00:00
grog
38b2dbfb9a Describe 'move' function.
Submitted-by:	Marius Bendiksen <marius@marius.scancall.no>

Describe state transitions in more detail, in particular how to revive
subdisks.
2000-01-05 05:59:08 +00:00
grog
fc064a10ef Change parameters of some declarations.
Add declaration for vinum_mv.
2000-01-05 05:58:01 +00:00
grog
5163962841 makedev: Give all devices permissions 740.
Suggested-by:	Bernd Walter (ticso@cicely.de)

Add key pairs for 'mv' and 'move' (a synonym for 'mv').  Required for
the move command code submitted by Marius Bendiksen
<marius@marius.scancall.no>

make_devices: Don't create symlinks for drives if they are only
referenced.  Previously, spurious symlinks appeared in the current
directory.

Problem-reported-by:	Bernd Walter (ticso@cicely.de)

No longer create character devices, now that there is no difference.
Make the devices as character devices, not block devices.
2000-01-05 05:57:31 +00:00
grog
3a196d655e Explicitly type large scalar parameters to avoid compilation warnings
on alpha.

Submitted-by:	Bernd Walter <ticso@cicely.de>

Replace %q formats with %lld.

Desired-by:	bde

Remove #ifdef RAID5

vinum_lsi: If a subdisk is in 'reviving' state, check the status of
the revive and report the status of the revive.  In verbose mode,
display the pid of the reviver.
2000-01-05 05:56:47 +00:00
grog
91cc3e9837 Explicitly type large scalar parameters to avoid compilation warnings
on alpha.

Submitted-by:	Bernd Walter <ticso@cicely.de>

Add function vinum_mv, which moves subdisks to different drives.  This
function just does the low-level configuration changes; the resultant
subdisk is stale if it previously had any contents, otherwise it is
empty (i.e. in need of initializing if it's RAID-5).  We still need to
handle getting the contents moved over, but the current version will
suffice to migrate subdisks from a disk which has failed.

Submitted-by:	Marius Bendiksen <marius@marius.scancall.no>

vinum_start:  Get the revive block size right.
2000-01-05 05:55:57 +00:00
marcel
5ed0012e79 Remove -g compiler flag. 2000-01-03 12:01:30 +00:00
grog
1e09a99ada Describe the new options of start and init commands. 1999-10-13 03:30:29 +00:00
grog
00578e9ef1 Change default init sizes from 64 kB to 60 kB, since the block device
interface limits it to this anyway.

Change the name of the v flag variable from 'verbose' to 'vflag',
indicating the multiple use (verbose or verify).

Add -S flag to specify the size of some operations.
1999-10-13 03:29:13 +00:00
grog
61c0c72ac5 Change the name of the v flag variable from 'verbose' to 'vflag',
indicating the multiple use (verbose or verify).

Add -S flag to specify the size of some operations.
1999-10-13 03:28:40 +00:00
grog
6615755ffc Change the name of the v flag variable from 'verbose' to 'vflag',
indicating the multiple use (verbose or verify).

vinum_ldi:
  Show active requests for the drive if -v is specified.
  White space cleanup.

vinum_lsi:
  Show the progress of an init command if -v is specified.

vinum_info:
  Print the number of active requests.

  Print out loginfo_sdio and loginfo_sdiodone log entries.
1999-10-13 03:27:55 +00:00
grog
dc37e533a4 Change the name of the v flag variable from 'verbose' to 'vflag',
indicating the multiple use (verbose or verify).

initsd: rewrite:
  Initialization is now done in the kernel.

  Verify (again!) if -v is specified.

  Allow specification of a blocksize, the length to be transferred in
  one transfer.

vinum_revive:
  Allow specification of a blocksize, the length to be transferred in
  one transfer.
1999-10-13 03:27:06 +00:00
grog
2343e64423 Add description of checkparity and rebuildparity.
Remove a half-started message.

Reported-by:	      "Jeffrey J. Mountin" <jeff@mountin.net>
1999-09-28 23:03:29 +00:00
grog
3d140252e4 Brucify comments.
vinum_lpi: Add information about progress of rebuildparity and
           checkparity commands.

listconfig: Print object counts in a different format, don't refer to
the internal number of slots allocated:

Caused-confusion-to:  Norbert Meissner <norbert.meissner@daimlerchrysler.com>

vinum_info: Change format of device numbers so that they fit in the
column (ignore high-order minor number bits, which aren't really of
much interest).
1999-09-28 23:02:14 +00:00
grog
dd9fd20194 vinum_init: Fix message typo.
vinum_start: bzero the statinfo.dinfo struct.  The lack of this was
causing sporadic failures of the start command.

Add body of vinum_checkparity command.
1999-09-28 23:00:05 +00:00
peter
76f0c923fe $Id$ -> $FreeBSD$ 1999-08-28 00:22:10 +00:00
grog
e225ec605b Update and tidy descriptions of info -V.
Describe use of -w option with start.
Tidy up descriptions of scale factor suffixes.
1999-08-26 03:24:02 +00:00
grog
10d42c8b30 Document the setstate command. 1999-08-24 02:36:23 +00:00
grog
b699dd5427 Change declaration for initsd.
Add declarations for vinum_setstate, vinum_checkparity and
vinum_rebuildparity.
1999-08-24 02:35:07 +00:00
grog
92e50861c3 parseline(): Reset the -w flag.
continue_revive: Implement the -w flag.
1999-08-24 02:33:55 +00:00
grog
edde6ee75c vinum_info(): Add support for logging subdisk I/O. 1999-08-24 02:32:57 +00:00
grog
922bb45cf9 Tidy up some indentation and comments.
vinum_init(): Change name of variable plexindex to objindex, which
	      better describes its purpose.

initsd(): Add a second parameter to determine whether it should wait
	  for completion or not.  This allows it to DTRT when called
	  with the -w flag either directly or via initplex().

Add 'setstate' command (function vinum_setstate ()) to implement the
VINUM_SETSTATE_FORCE ioctl for diddling individual object states.
This is a repair tool which can also be used for panicing the system.
Use with utmost care if at all.

Add unimplemented commands 'checkparity' and 'rebuildparity'.  Watch
this space.
1999-08-24 02:31:19 +00:00
mpp
2037b3d265 Minor mdoc fix. 1999-08-15 12:16:59 +00:00
mpp
ebc58e0b20 Various man page cleanup:
- Sort xrefs
- FreeBSD.ORG -> FreeBSD.org
- Properly xref RFCs.
- Be consistent with section names as outlined in mdoc(7).
- Other misc mdoc cleanup.

PR:		doc/13144
Submitted by:	Alexey M. Zelkin <phantom@cris.net>
1999-08-15 08:06:12 +00:00
grog
5913fc232b initsd: On completion, put the subdisk in 'initialized' status, not
'up'.  This matches changes in the kernel module.

Reported-by:	Bernd Walter <ticso@cicely.de>
		Remy Nonnenmacher <remy@synx.com>
1999-08-15 02:32:19 +00:00
grog
e8c163e370 Correct typo. 1999-08-14 09:15:43 +00:00
grog
72af637c3c Add declarations for initvol, initplex and initsd helper functions for
vinum_init.
1999-08-14 06:20:55 +00:00
grog
8effe71628 vinum_info: add code to print out lock events.
modify format of other event printouts.
1999-08-14 06:20:20 +00:00
grog
a0bee57f34 make_plex_dev: make them raw. Volume-related plex devices will
probably die a death soon (yes, DES, that's correct usage).
1999-08-14 06:19:38 +00:00
grog
b435818c5a vinum_init: add code to initialize subdisks as well as plexes. Also
provide for initializing volumes; this code is not yet complete.
1999-08-14 06:18:39 +00:00
grog
c45cdc42a2 Correct typo.
PR:	docs/13050
Reported-by:	Dan Langille<junkmale@xtra.co.nz>
1999-08-09 23:28:03 +00:00
grog
85f9772cfe Update to reflect recent changes. 1999-08-07 09:27:25 +00:00
grog
e66df31c62 Remove code to detect RAID-5/non-RAID-5 kernel modules. 1999-08-07 08:20:07 +00:00
grog
14c3e50601 Remove code to detect RAID-5/non-RAID-5 kernel modules.
Add function definition for readpol command.

Rewrite make_devices with a view to incremental making.  In the
process, effectively kill off plex-bound subdisk device numbers.
1999-08-07 08:19:45 +00:00
grog
150ef09ae8 Import RAID-5 code.
Add Cybernet copyright.

OK'd-by:     Chuck Jacobus <chuck@cybernet.com>

vinum_ldi:
  Calculate the percentage used correctly.

vinum_lsi:
  Flag detached subdisks.

vinum_info:
  Request info: get the major and minor numbers and print them
  correctly.

list_defective_objects:
  New function, for listing objects which aren't up after vinum_start.

  Requested-by: Steve Taylor <staylor@cybernet.com>
1999-08-07 08:19:15 +00:00
grog
644b832941 vinum_init:
wait correctly for completion.
   set object in initializing state before initializing.
   Don't set the plex up, it should go up automatically.

vinum_start:
  If any objects are not up on start, list them.

  Requested-by: Steve Taylor <staylor@cybernet.com>

vinum_attach:
  Make sure we always have the object information before examining it.

vinum_replace:
  Start writing.

create_drive, vinum_concat, vinum_stripe, vinum_mirror:
  Check the ioctl return values correctly

vinum_readpol:
  Start writing.
1999-08-07 08:18:39 +00:00
grog
83880cb904 Modify device numbering method to work with latest -CURRENT. Briefly,
the device numbers are now minor number only, so that we can still
compare them after dev_t has turned into a blob.

Broken-by:	dev_t changes
Reported-by:	Vallo Kallaste <vallo@matti.ee>
		"Niels Chr. Bank-Pedersen" <ncbp@bank-pedersen.dk>
1999-07-22 08:40:37 +00:00
grog
ed93915465 Add definitions for simplified config commands
Change definition of sflag

Reported-by:	Johan Karlsson <k@numeri.campus.luth.se>
		Doug <Doug@gorean.org>
		green

World-broken-by:	grog
Pointy-hat-passed-to:	grog
1999-07-02 23:57:45 +00:00
grog
3d2b8409c4 Remove the volume, plex, sd and drive commands which allowed the user
to bypass the create command.

vinum_stop:
  Allow -f option.

Add commands for simplified configuration:
  concat - create a volume with one concatenated plex
  stripe - create a volume with one striped plex
  mirror - create a volume with two concatenated or striped plexes

Egged-on-by:	  jkh
1999-07-02 08:01:12 +00:00