- Replace the global driver lock with a per-instance device lock.
- Use the per-instance device lock instead of Giant for the CAM sim lock.
- Add global locks to protect the adapter list and DPC queues.
- Use wakeup() and mtx_sleep() to wait for certain events like the
controller going idle rather than polling via timeouts passed to
tsleep().
- Use callout(9) instead of timeout(9).
- Mark the interrupt handler MPSAFE.
- Remove compat shims for FreeBSD versions older than 8.0.
Reviewed by: Steve Chang <ychang@highpoint-tech.com>
here is the support for amd64, as well as possible support for PAE. Many
thanks to Highpoint for continuing to support FreeBSD.
Obtained from: Steve Chang @ Highpoint
MFC After: 3 days.