Commit Graph

316 Commits

Author SHA1 Message Date
pjd
595eb1de94 The 'ret' variable is of type ssize_t and we use proper format for it (%zd), so
no (bogus) cast is needed.

MFC after:	3 days
2010-12-16 19:48:03 +00:00
pjd
04dabf8bdf Improve problems logging.
MFC after:	3 days
2010-12-16 07:30:47 +00:00
pjd
aa49a373c5 Don't ignore errors from remote requests.
MFC after:	3 days
2010-12-16 07:29:58 +00:00
pjd
4e9dd0a507 Log the fact of launching and include protocol version number.
MFC after:	3 days
2010-12-16 07:28:40 +00:00
brucec
3aec76f035 Don't generate input() since it's not used. 2010-11-22 14:16:22 +00:00
pjd
ec5f555493 Move timeout.tv_sec initialization outside the loop - sigtimedwait(2) won't
modify it.

Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-11-15 03:07:42 +00:00
pjd
781dd0dfd8 1. Exit when we cannot create incoming connection.
2. Improve logging to inform which connection can't be created.

Submitted by:	[1] Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-11-15 03:05:33 +00:00
pjd
c148a74821 Send packets to remote node only via the send thread to avoid possible
races - in this case a keepalive packet was send from wrong thread which
lead to connection dropping, because of corrupted packet.

Fix it by sending keepalive packets directly from the send thread.
As a bonus we now send keepalive packets only when connection is idle.

Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-11-02 22:13:08 +00:00
pjd
0a39257e36 Before this change on first connect between primary and secondary we
initialize all the data. This is huge waste of time and resources if
there were no writes yet, as there is no real data to synchronize.

Optimize this by sending "virgin" argument to secondary, which gives it a hint
that synchronization is not needed.

In the common case (where noth nodes are configured at the same time) instead
of synchronizing everything, we don't synchronize at all.

MFC after:	1 week
2010-10-24 17:28:25 +00:00
pjd
9eb542816d Implement nv_exists() function that returns true if argument of the given
name exists.

MFC after:	3 days
2010-10-24 17:24:08 +00:00
pjd
cd45fc19c2 Move all NV defines into nv.c, they are not used externally thus there is
no need to make then visible from outside.

MFC after:	3 days
2010-10-24 17:22:34 +00:00
pjd
126799a04f Simplify code a bit.
MFC after:	3 days
2010-10-24 15:44:23 +00:00
pjd
8bd78aab88 Plug memory leak.
MFC after:	3 days
2010-10-24 15:42:16 +00:00
pjd
8b3f940d77 Plug memory leaks.
Found with:	valgrind
MFC after:	3 days
2010-10-24 15:41:23 +00:00
pjd
0b068ae424 Load geom_gate.ko module after parsing arguments.
MFC after:	3 days
2010-10-24 15:38:58 +00:00
pjd
ff47d7260c Use closefrom(2) instead of close(2) in a loop.
MFC after:	1 week
2010-10-20 21:10:01 +00:00
pjd
4212acad62 Log correct connection when canceling half-open connection.
Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-10-17 15:47:27 +00:00
pjd
0d755a144b Use one fprintf() instead of two.
MFC after:	3 days
2010-10-16 22:50:12 +00:00
pjd
884d1009d2 Clear signal mask before executing a hook.
Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-10-16 22:48:48 +00:00
pjd
8243d099e8 We can't zero out ggio request, as we have some fields in there we initialize
once during start-up.

Reported by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-10-08 15:05:39 +00:00
pjd
322c5f284c We close the event socketpair early in the mainloop to prevent spaming with
error messages, so when we clean up after child process, we have to check if
the event socketpair is still there.

Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-10-08 15:02:15 +00:00
pjd
472b886ca9 Clear ggate structures before using them. We don't initialize all the field
and there can be some garbage from the stack.

MFC after:	1 week
2010-10-07 18:23:28 +00:00
pjd
74e7b90374 Log error message when we fail to destroy ggate provider.
MFC after:	3 days
2010-10-07 18:20:16 +00:00
pjd
3293cba127 Start the guard thread first, so we can handle signals from the very begining.
Reported by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	1 week
2010-10-07 18:19:02 +00:00
pjd
52123d5272 Don't close local component on exit as we can hang waiting on g_waitidle.
I'm unable to reproduce the race described in comment anymore and also the
comment is incorrect - localfd represents local component from configuration
file, eg. /dev/da0 and not HAST provider.

Reported by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	1 week
2010-10-07 18:16:22 +00:00
pjd
10add0447c Decrease report interval to 5 seconds, as this also means we will check for
signals every 5 seconds and not every 10 seconds as before.

MFC after:	3 days
2010-10-04 21:44:26 +00:00
pjd
b85b0868d9 hook_check() is now only used to report about long-running hooks, so the
argument is redundant, remove it.

MFC after:	3 days
2010-10-04 21:43:06 +00:00
pjd
0651a7ac68 We can't mask ignored signal, so install dummy signal hander for SIGCHLD before
masking it.

This fixes bogus reports about hooks running for too long and other problems
related to garbage-collecting child processes.

Reported by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-10-04 21:41:18 +00:00
pjd
22936fe435 Plug memory leak on fork(2) failure.
Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-09-26 10:39:01 +00:00
pjd
67279d16ee Switch to sigprocmask(2) API also in the main process and secondary process.
This way the primary process inherits signal mask from the main process,
which fixes a race where signal is delivered to the primary process before
configuring signal mask.

Reported by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-09-22 19:08:11 +00:00
pjd
2eee4ca70d Assert that descriptor numbers are sane.
MFC after:	3 days
2010-09-22 19:05:54 +00:00
pjd
9433a082e8 Fix possible deadlock where worker process sends an event to the main process
while the main process sends control message to the worker process, but worker
process hasn't started control thread yet, because it waits for reply from the
main process.

The fix is to start the control thread before sending any events.

Reported and fix suggested by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-09-22 19:03:11 +00:00
pjd
3657e3ff87 Fix descriptor leaks: when child exits, we have to close control and event
socket pairs. We did that only in one case out of three.

MFC after:	3 days
2010-09-22 18:57:06 +00:00
pjd
33133813bc If we are unable to receive control message is most likely because the main
process died. Instead of entering infinite loop, terminate.

MFC after:	3 days
2010-09-22 18:39:43 +00:00
pjd
e7991e6689 Sort includes.
MFC after:	3 days
2010-09-22 18:38:02 +00:00
pjd
999124921a Add __dead2 to functions that we know they are going to exit.
MFC after:	3 days
2010-09-20 13:23:43 +00:00
pjd
1c05a32422 Include process PID in log messages.
Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	2 weeks
2010-08-31 12:05:13 +00:00
pjd
d9a5627136 Correct error message.
Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	2 weeks
2010-08-31 12:03:29 +00:00
pjd
fdecdfad04 Forgot to add event.c and event.h in r212038.
Pointed out by:	pluknet <pluknet@gmail.com>
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-31 09:38:43 +00:00
pjd
7476d01cc9 Mask only those signals that we want to handle.
Suggested by:	jilles
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-31 06:22:03 +00:00
pjd
9b4ae63e78 Because it is very hard to make fork(2) from threaded process safe (we are
limited to async-signal safe functions in the child process), move all hooks
execution to the main (non-threaded) process.

Do it by maintaining connection (socketpair) between child and parent
and sending events from the child to parent, so it can execute the hook.

This is step in right direction for others reasons too. For example there is
one less problem to drop privs in worker processes.

MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-30 23:26:10 +00:00
pjd
8a7b72b9d3 We only want to know if descriptors are ready for reading.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-30 23:19:21 +00:00
pjd
95ca781a2e When someone gives NULL as data, assume this is because he want to declare
connection side only.

MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-30 23:16:45 +00:00
pjd
107a540b8b Use pjdlog_exit() before fork().
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-30 22:28:04 +00:00
pjd
f116a70c0d Constify arguments we can constify.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-30 22:26:42 +00:00
pjd
e14a354a91 Execute hook when connection between the nodes is established or lost.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-30 00:31:30 +00:00
pjd
2357642204 Execute hook when split-brain is detected.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-30 00:12:10 +00:00
pjd
72d737839c Use sigtimedwait(2) for signals handling in primary process.
This fixes various races and eliminates use of pthread* API in signal handler.

Pointed out by:	kib
With help from:	jilles
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-30 00:06:05 +00:00
pjd
4ad9896077 - Move functionality responsible for checking one connection to separate
function to make code more readable.
- Be sure not to reconnect too often in case of signal delivery, etc.

MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-29 22:55:21 +00:00
pjd
39e5544fc3 Disconnect after logging errors.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-29 22:17:53 +00:00
pjd
1d4a51dd2d - Call hook on role change.
- Document new event.

MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-29 21:42:45 +00:00
pjd
70a52f0307 Allow to run hooks from the main hastd process.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-29 21:41:53 +00:00
pjd
9a66bc9a30 - Add hook_fini() which should be called after fork() from the main hastd
process, once it start to use hooks.
- Add hook_check_one() in case the caller expects different child processes
  and once it can recognize it, it will pass pid and status to hook_check_one().

MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-29 21:39:49 +00:00
pjd
4a3477caff Implement mtx_destroy() and rw_destroy().
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-29 21:37:21 +00:00
pjd
98dd369bdd When SIGTERM or SIGINT is received, terminate worker processes.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 21:28:02 +00:00
pjd
db793cba89 When logging to stdout/stderr, flush after each log.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 21:26:55 +00:00
pjd
ae9ec59c50 Correct when we log interrupted synchronization.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 21:20:32 +00:00
pjd
e55034b622 Check if no signals were delivered just before going to sleep.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 20:49:06 +00:00
pjd
bd949b7dfc Add hooks execution.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 20:48:12 +00:00
pjd
4b6cfc055c Document new 'exec' parameter.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 15:20:31 +00:00
pjd
74741a8c60 Allow to execute specified program on various HAST events.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 15:16:52 +00:00
pjd
aeab5efe07 - Run hooks in background - don't block waiting for them to finish.
- Keep all hooks we're running in a global list, so we can report when
  they finish and also report when they are running for too long.

MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 14:38:12 +00:00
pjd
dd3961e615 When logging to stdout/stderr don't close those descriptors after fork().
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 14:35:39 +00:00
pjd
ac5c9c9216 Reduce indent where possible.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 14:28:39 +00:00
pjd
ead19aaef1 Implement keepalive mechanism inside HAST protocol so we can detect secondary
node failures quickly for HAST resources that are rarely modified.

Remove XXX from a comment now that the guard thread never sleeps infinitely.

MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 14:26:37 +00:00
pjd
8729a28322 - Remove redundant and incorrect 'old' word from debug message.
- Log disconnects as warnings.

MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 14:12:53 +00:00
pjd
0a7a46d1e3 Don't increase number synchronized bytes in case of an error.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 14:10:25 +00:00
pjd
a3721f8d1b Log that synchronization was interrupted in a proper place.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 14:08:10 +00:00
pjd
b51d684000 We have sync_start() function to start synchronization, introduce sync_stop()
function to stop it.

MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 14:06:00 +00:00
pjd
79f0171a3e Add QUEUE_INSERT() and QUEUE_TAKE() macros that simplify the code a bit.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 14:01:28 +00:00
pjd
ef9c1a15b4 Add mtx_owned() implementation.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 13:58:38 +00:00
pjd
29f3bd82d2 Make comment more readable.
MFC after:	2 weeks
Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
2010-08-27 13:54:17 +00:00
pjd
395a43623f For some setups sending data in 128kB chunks makes communication very slow. No
idea why. 32kB on the other hand seems to work properly everywhere.

Reported by:	Thomas Steen Rasmussen <thomas@gibfest.dk>
MFC after:	3 weeks
2010-08-18 12:09:27 +00:00
pjd
46021d25fa The 'size' variable is there to limit how many bytes we want to copy from
'addr'. It is very likely that size of 'addr' is larger than 'size', so checking
strlcpy() return value is bogus.

MFC after:	3 weeks
2010-08-16 21:59:56 +00:00
joel
dd1fff9bcb Fix typos, spelling, formatting and mdoc mistakes found by Nobuyuki while
translating these manual pages.  Minor corrections by me.

Submitted by:	Nobuyuki Koganemaru <n-kogane@syd.odn.ne.jp>
2010-08-16 15:18:30 +00:00
pjd
d71ba1ed02 Document 'none' value for remote.
Reviewed by:	dougb
MFC after:	1 month
2010-08-05 19:54:57 +00:00
pjd
7a18b662f1 Implement configuration reload on SIGHUP. This includes:
- Load added resources.
- Stop and forget removed resources.
- Update modified resources in least intrusive way, ie. don't touch
  /dev/hast/<name> unless path to local component or provider name were
  modified.

Obtained from:	Wheel Systems Sp. z o.o. http://www.wheelsystems.com
MFC after:	1 month
2010-08-05 19:16:31 +00:00
pjd
7bbad9d8f8 Prepare configuration parsing code to be called multiple times:
- Don't exit on errors if not requested.
- Don't keep configuration in global variable, but allocate memory for
  configuration.
- Call yyrestart() before yyparse() so that on error in configuration file
  we will start from the begining next time and not from the place we left of.

MFC after:	1 month
2010-08-05 19:08:54 +00:00
pjd
31021ec9f1 Make control_set_role() more public. We will need it soon.
MFC after:	1 month
2010-08-05 19:04:29 +00:00
pjd
64f20fee87 Allow to use 'none' keywork as remote address in case second cluster node
is not setup yet.

MFC after:	1 month
2010-08-05 19:01:57 +00:00
pjd
25464151ef Reset signal handlers after fork().
MFC after:	1 month
2010-08-05 18:58:00 +00:00
pjd
ed23731ef1 - Use pjdlog_exitx() to log errors and exit instead of errx().
- Use 'unable to' (instead of 'cannot') consistently.

MFC after:	1 month
2010-08-05 18:56:24 +00:00
pjd
8f25a1f569 Assert that various buffers we are large enough.
MFC after:	1 month
2010-08-05 18:27:41 +00:00
pjd
ca14b5deab Problem with assertion is that it logs on stderr. Add two macros:
PJDLOG_ASSERT() and PJDLOG_VERIFY() that will check the given condition
and log the problem where appropriate. The difference between those
two is that PJDLOG_VERIFY() always work and PJDLOG_ASSERT() can be
turned off by defining NDEBUG.

MFC after:	1 month
2010-08-05 18:26:38 +00:00
pjd
dd50434feb Keep $FreeBSD$ in __FBSDID() only for C files.
MFC after:	1 month
2010-08-05 18:23:43 +00:00
pjd
5df4a855e5 Mark two more places that we won't reach.
MFC after:	1 month
2010-08-05 18:21:45 +00:00
pjd
d222eba6ff Now that TCP will be checked last we don't need any knowledge about other
protocols.

MFC after:	1 month
2010-08-05 17:57:59 +00:00
pjd
d808f64f39 Add an argument to the proto_register() function which allows protocol to
declare it is the default and be placed at the end of the queue so it is
checked last.

MFC after:	1 month
2010-08-05 17:56:41 +00:00
joel
be2c32910f Spelling fixes. 2010-07-31 21:09:49 +00:00
pjd
3f34a9652f Actually, only the fullsync mode is implemented, not memsync mode.
Correct manual page.

MFC after:	3 days
2010-07-22 08:30:14 +00:00
pjd
30cb3140ef Correct various log messages.
Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-06-14 21:46:48 +00:00
pjd
235822ad57 Fix typos.
MFC after:	3 days
2010-06-14 21:44:58 +00:00
pjd
05cedac6b7 Initialize gctl_seq for synchronization requests.
Reported by:	hiroshi@soupacific.com
Analysed by:	Mikolaj Golub <to.my.trociny@gmail.com>
Tested by:	hiroshi@soupacific.com, Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-06-14 21:44:20 +00:00
pjd
8a3620394e Plug memory leak.
Found by:	Coverity Prevent
CID:		7057
MFC after:	3 days
2010-06-14 21:41:22 +00:00
pjd
4d60221630 Plug memory leak.
Found by:	Coverity Prevent
CID:		7056
MFC after:	3 days
2010-06-14 21:37:25 +00:00
pjd
d5bb9ec5ff Plug memory leak.
Found by:	Coverity Prevent
CID:		7051
MFC after:	3 days
2010-06-14 21:33:18 +00:00
pjd
ccd077e269 Plug memory leaks.
Found by:	Coverity Prevent
CID:		7052, 7053, 7054, 7055
MFC after:	3 days
2010-06-14 21:25:20 +00:00
pjd
7824be8be0 Remove macros that are not really needed. The idea was to have them in case
we grow more descriptors, but I'll reconsider readding them once we get there.

Passing (a = b) expression to FD_ISSET() is bad idea, as FD_ISSET() evaluates
its argument twice.

Found by:	Coverity Prevent
CID:		5243
MFC after:	3 days
2010-06-14 21:18:58 +00:00
pjd
e6a1cebf1a Eliminate dead code.
Found by:	Coverity Prevent
CID:		5158
MFC after:	3 days
2010-06-14 21:01:13 +00:00
uqs
64c451d29e mdoc: move remaining sections into consistent order
This pertains mostly to FILES, HISTORY, EXIT STATUS and AUTHORS sections.

Found by:	mdocml lint run
Reviewed by:	ru
2010-05-13 12:08:11 +00:00
pjd
1f717ed2d0 Default connection timeout is way too long. To make it shorter we have to
make socket non-blocking, connect() and if we get EINPROGRESS, we have to
wait using select(). Very complex, but I know no other way to define
connection timeout for a given socket.

Reported by:	hiroshi@soupacific.com
MFC after:	3 days
2010-04-29 21:55:20 +00:00
pjd
db164aeb15 - Check if the worker process was killed by signal and restart it.
- Improve logging.

Pointed out by:	Garrett Cooper <yanefbsd@gmail.com>
MFC after:	3 days
2010-04-29 15:42:24 +00:00
pjd
0dcf2ac7ad Fix a problem where hastd will stuck in recv(2) after sending request to
secondary, which died between send(2) and recv(2). Do it by adding timeout
to recv(2) for primary incoming and outgoing sockets and secondary outgoing
socket.

Reported by:	Mikolaj Golub <to.my.trociny@gmail.com>
Tested by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-04-29 15:36:32 +00:00
pjd
b9745c56c3 Restart worker thread only if the problem was temporary.
In case of persistent problem we don't want to loop forever.

MFC after:	3 days
2010-04-28 22:41:06 +00:00
pjd
0b8041abdd Mark temporary issues as such.
MFC after:	3 days
2010-04-28 22:39:47 +00:00
pjd
166a203d5e Use WEXITSTATUS() to obtain real exit code.
MFC after:	3 days
2010-04-28 22:26:30 +00:00
pjd
c28c8b4fa8 Don't assume that "resource" property is in metadata.
Reported by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-04-28 22:23:29 +00:00
pjd
0ecd3895a8 Fix compilation with WITHOUT_CRYPT or WITHOUT_OPENSSL options.
Reported by:	Andrei V. Lavreniyuk <andy.lavr@reactor-xg.kiev.ua>
MFC after:	3 days
2010-04-22 19:18:10 +00:00
pjd
1181490d6c Fix log size calculation which caused message truncation.
Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-04-16 06:49:12 +00:00
pjd
9358f8fa2b Fix control socket leak when worker process exits.
Submitted by:	Mikolaj Golub <to.my.trociny@gmail.com>
MFC after:	3 days
2010-04-16 06:47:29 +00:00
pjd
c133fa9590 Increase ggate queue size to maximum value.
HAST was not able to stand heavy random load.

Reported by:	Hiroyuki Yamagami
MFC after:	3 days
2010-04-15 17:04:08 +00:00
pjd
d24a127c68 Don't hold connection lock when doing reconnects as it makes I/Os wait for
connection timeouts.

Reported by:	Kevin Day <toasty@dragondata.com>
2010-03-27 16:35:07 +00:00
uqs
4a10ff6f04 Remove redundant WARNS?=6 overrides and inherit the WARNS setting from
the toplevel directory.

This does not change any WARNS level and survives a make universe.

Approved by:        ed (co-mentor)
2010-03-02 18:44:08 +00:00
ru
7cea019b6c Fixed static linkage. 2010-02-26 09:41:16 +00:00
pjd
16e435ca61 Changing proto_socketpair.c compilation and linking order revealed
a problem - we should simply ignore proto_server() if address
doesn't start with socketpair://, and not abort.
2010-02-21 19:56:47 +00:00
pjd
1c1e2e8b71 Please welcome HAST - Highly Avalable Storage.
HAST allows to transparently store data on two physically separated machines
connected over the TCP/IP network. HAST works in Primary-Secondary
(Master-Backup, Master-Slave) configuration, which means that only one of the
cluster nodes can be active at any given time. Only Primary node is able to
handle I/O requests to HAST-managed devices. Currently HAST is limited to two
cluster nodes in total.

HAST operates on block level - it provides disk-like devices in /dev/hast/
directory for use by file systems and/or applications. Working on block level
makes it transparent for file systems and applications. There in no difference
between using HAST-provided device and raw disk, partition, etc. All of them
are just regular GEOM providers in FreeBSD.

For more information please consult hastd(8), hastctl(8) and hast.conf(5)
manual pages, as well as http://wiki.FreeBSD.org/HAST.

Sponsored by:	FreeBSD Foundation
Sponsored by:	OMCnet Internet Service GmbH
Sponsored by:	TransIP BV
2010-02-18 23:16:19 +00:00