24 Commits

Author SHA1 Message Date
Ulf Lilleengen
c0b9797aa8 Import the gvinum work that have been done during and after Summer of Code 2007.
The work have been under testing and fixing since then, and it is mature enough
to be put into HEAD for further testing.

A lot have changed in this time, and here are the most important:
- Gvinum now uses one single workerthread instead of one thread for each
  volume and each plex. The reason for this is that the previous scheme was
  very complex, and was the cause of many of the bugs discovered in gvinum.
  Instead, gvinum now uses one worker thread with an event queue, quite
  similar to what used in gmirror.
- The rebuild/grow/initialize/parity check routines no longer runs in
  separate threads, but are run as regular I/O requests with special flags.
  This made it easier to support mounted growing and parity rebuild.
- Support for growing striped and raid5-plexes, meaning that one can extend the
  volumes for these plex types in addition to the concat type. Also works while
  the volume is mounted.
- Implementation of many of the missing commands from the old vinum:
  attach/detach, start (was partially implemented), stop (was partially
  implemented), concat, mirror, stripe, raid5 (shortcuts for creating volumes
  with one plex of these organizations).
- The parity check and rebuild no longer goes between userland/kernel, meaning
  that the gvinum command will not stay and wait forever for the rebuild to
  finish. You can instead watch the status with the list command.
- Many problems with gvinum have been reported since 5.x, and some has been hard
  to fix due to the complicated architecture. Hopefully, it should be more
  stable and better handle edge cases that previously made gvinum crash.
- Failed drives no longer disappears entirely, but now leave behind a dummy
  drive that makes sure the original state is not forgotten in case the system
  is rebooted between drive failures/swaps.
- Update manpage to reflect new commands and extend it with some examples.

Sponsored by:   Google Summer of Code 2007
Mentored by:    le
Tested by:      Rick C. Petty <rick-freebsd2008 -at- kiwi-computer.com>
2009-03-28 17:20:08 +00:00
Ulf Lilleengen
7e11b694f4 - Fix a potential NULL pointer reference. Note that this cannot happen in
practice, but it is a good programming practice nontheless and it allows the
  kernel to not depend on userland correctness.

Found with:   Coverity Prevent(tm)
CID:          655-659, 664-667
2008-11-25 19:13:58 +00:00
Ulf Lilleengen
86b3c6f5bc - Import macros used in gmirror for printing gvinum debug messages and making
the output more standardized.
- Add a sysctl to set the verbosity of the debug messages.
- While there, fixup typos and wording in the messages.
2008-10-26 17:20:37 +00:00
Lukas Ertl
ff91880e5d Protect from creating striped and RAID5 plexes with unequally sized
subdisks.
2006-03-30 14:01:25 +00:00
Lukas Ertl
7b5264faa1 Implement the 'resetconfig' command.
PR:            kern/94835
Submitted by:  Ulf Lilleengen <lulf@stud.ntnu.no>
2006-03-23 19:58:43 +00:00
Lukas Ertl
e30534d50b Since we want a vinum geom created anytime the module loads, move
the geom creation to a seperate init function and ignore the tasting.

The config is now parsed only in the vinumdrive geom, which hopefully
fixes the problem, that the drive class tasted before the vinum class
had a chance, for good.

Also restore the behaviour that the module can be loaded at boot time
and on a running system.
2005-11-24 15:11:41 +00:00
Lukas Ertl
57335408d4 Finally bring in what was produced during Google SoC 2005:
Add functions to rename objects and to move a subdisk from one drive
to another.

Obtained from:  Chris Jones <chris.jones@ualberta.ca>
Sponsored by:   Google Summer of Code 2005
MFC in:         1 week
2005-11-19 20:25:18 +00:00
Lukas Ertl
8cc5eb98ad Fix a stupid logic bug introduced in geom_vinum_drive.c rev 1.18:
When a drive is newly created, it's state is initially set to 'down',
so it won't allow saving the config to it (thus it will never know of
itself being created).  Work around this by adding a new flag, that's
also checked when saving the config to a drive.
2005-08-15 17:07:47 +00:00
Lukas Ertl
cf01c54cda Remove test for zero sectorsize when tasting. This check doesn't
seem to be necessary anymore, and it prevents tasting a valid drive
when booting with geom_vinum already loaded, since SCSI disks set their
sectorsize not until first opening them.
2005-03-07 19:58:58 +00:00
Warner Losh
fa521b0366 /* -> /*- for copyright notices, minor format tweaks as necessary 2005-01-06 18:27:30 +00:00
Lukas Ertl
997337fd20 Implement 'setstate' to allow setting the state of drives and subdisks
for debugging and emergency purposes.
2004-11-26 12:31:36 +00:00
Lukas Ertl
fb5885af37 Implement checkparity/rebuildparity. 2004-11-26 12:01:00 +00:00
Lukas Ertl
4cb1b18827 Don't allow to create a drive that already exists. 2004-10-02 20:50:21 +00:00
Lukas Ertl
ea29a30466 Read a whole sector instead of GV_HDR_LEN, since a sector might be
bigger (i.e. on CD-ROMs).
2004-09-13 17:27:58 +00:00
Lukas Ertl
5bad268cdc Move config_new_drive() to the correct place and rename it to
gv_config_new_drive().
2004-08-27 21:32:18 +00:00
Poul-Henning Kamp
5721c9c76a Tag all geom classes in the tree with a version number. 2004-08-08 07:57:53 +00:00
Lukas Ertl
07c424cdaf Shut up the compiler and temporarily '#if 0' gv_destroy_geom(),
until we need it again.
2004-07-29 11:32:09 +00:00
Lukas Ertl
c291a77678 Use a temporary geom when tasting vinumdrives and lock the 'real'
vinumdrive geom with an exclusive bit.  This should fix the problem
when underlying partitions overlap (i.e. the 'a' partition is at
the same offset as the 'c' partition).

Ideas borrowed from pjd@, quite a bit of testing by
Matthias Schuendehuette <msch@snafu.de>.
2004-07-24 22:26:40 +00:00
Lukas Ertl
6db345b90e Disable kldunloading of geom_vinum temporarily until I figured out
how to do it correctly.
2004-07-24 19:04:24 +00:00
Pawel Jakub Dawidek
1b39b2f671 g_clone_bio() can fail, be ready for this.
Approved by:	le
2004-07-05 13:24:22 +00:00
Lukas Ertl
865897c9f1 Mark a plex as 'newborn' when it is created. This is used to indicate
that new RAID5 plexes need to be initialized first.
2004-06-25 18:04:33 +00:00
Christian S.J. Peron
d7af790b0d Currently, if the drives specified for volume creation are
not active GEOM providers, it will result in a kernel panic.

If the GEOM provider or disk goes away before the volume
configuration data gets written to the disk, it will result
in another kernel panic.

o Make sure that the drives specified for volume creation
  are active GEOM providers.

o When writing out volume configuration data to associated drives,
  make sure that the GEOM provider is active, otherwise continue
  to the next drive in the volume.

Approved by:	le, bmilekic (mentor)
2004-06-24 02:40:34 +00:00
Lukas Ertl
7f72de2d55 Clean up allocated ressources when destroying the main vinum geom. 2004-06-18 19:53:33 +00:00
Lukas Ertl
73679edcc7 Add a first version of a GEOMified vinum. 2004-06-12 21:16:10 +00:00