The kernel won't crash if you have a bad value and I'd rather not have
nvmecontrol know the internal details about how the nvme driver limits
the transfer size.
addition, the flags are optional, but were made to be mandatory. Set
these things, as well as santiy check the specified size.
Submitted by: Stefan Rink
PR: 240798
':'. It's slightly wasteful, but much easier (and the savings in bytes
at runtime would be tiny, but the code to do it larger).
Submitted by: Sebastian Huber
The Host Buffer feature (NVMe 1.4 section 89) allows for the NVMe card
request the host provide it buffer for lookaside tables and maybe
other things. Report the card's minimum and preferred sizes with
nvmecontrol/camcontrol identify.
I merged passthru.c from the wrong branch (it was a branch that went further in
a direction I wound up not taking). Fix the mismerge and turn passthru on.
NVMe reservations are quite alike to SCSI persistent reservations and
can be used in clustered setups with shared multiport storage.
MFC after: 10 days
Relnotes: yes
Sponsored by: iXsystems, Inc.
It allows to delete all user data from NVM subsystem in one of 3 methods.
It is a close equivalent of SCSI SANITIZE command of `camcontrol sanitize`,
so I tried to keep arguments as close as possible.
While there, fix supported sanitize methods reporting in `identify`.
MFC after: 2 weeks
Relnotes: yes
Sponsored by: iXsystems, Inc.
In particular: Changed Namespace List, Commands Supported and Effects,
Reservation Notification, Sanitize Status.
Add few new arguments to `nvmecontrol log` subcommand.
MFC after: 2 weeks
Sponsored by: iXsystems, Inc.
While very useful by itself, it also makes `nvmecontrol` not depend on
hardcoded device names parsing, that in its turn makes simple to take
nvdX (and potentially any other) device names as arguments.
Also added IOCTL bypass from nvdX to respective nvmeYnsZ makes them
interchangeable for management purposes.
MFC after: 2 weeks
Sponsored by: iXsystems, Inc.
This adds several previously missed but important subcommands to list
namespaces and controllers. It also fixes few previously added but
just found with real testing to be broken subcommands.
Also while there, add possibility to explicitly specify nsid for
`nvmecontrol identify` subcommand. It may be useful to specify nsids
not having own devices, for example 0xffffffff, or just newly created
ones.
MFC after: 2 weeks
Relnotes: yes
Sponsored by: iXsystems, Inc.
These are mostly compatible with Linux, with three exceptions.
1. We don't do metadata segment stuff. Our passthrough interface
doesn't cope. The code is there, but generates an error.
2. Linux lets you specify a namespace ID for the command. We current
do not: we get ours from the namespace device, or pass in a generic
one. Generally, this will lead to the same command, but FreeBSD's
is safer since you can't specify the wrong id.
3. --show-command outputs to stderr instead of stdout so you can both
see your command, and capture its output with a simple redirect.
Differential Revision: https://reviews.freebsd.org/D19296
Create a set of routines and structures to hold the data for the args
for a command. Use them to generate help and to parse args. Convert
all the current commands over to the new format. "comnd" is a hat-tip
to the TOPS-20 %COMND JSYS that (very) loosely inspired much of the
subsequent command line notions in the industry, but this is far
simpler (the %COMND man page is longer than this code) and not in the
kernel... Also, it implements today's de-facto
command [verb]+ [opts]* [args]*
format rather than the old, archaic TOPS-20 command format :)
This is a snapshot of a work in progress to get the nvme passthru
stuff committed. In time it will become a private library and used
by some other programs in the tree that conform to the above pattern.
Differential Revision: https://reviews.freebsd.org/D19296
Move from using a linker set to a constructor function that's
called. This simplifies the code and is slightly more obvious. We now
keep a list of page decoders rather than having an array we managed
before. Commands will move to something similar in the future.
Reviewed by: jhb@
Differential Revision: https://reviews.freebsd.org/D19275
Use recent best practices for Copyright form at the top of
the license:
1. Remove all the All Rights Reserved clauses on our stuff. Where we
piggybacked others, use a separate line to make things clear.
2. Use "Netflix, Inc." everywhere.
3. Use a single line for the copyright for grep friendliness.
4. Use date ranges in all places for our stuff.
Approved by: Netflix Legal (who gave me the form), adrian@ (pmc files)
The nvmecontrol code that did the devlist assumed that we had a
tightly-packed allocation of units. Since pci writing exists, this
isn't the case. Loop over the first 256 units, which is a reasonable
number of possible units.
Sponsored by: Netflix
Other vendors base their additional smart info pages on what Intel did
plus some other bits. So it's convenient to have this be global.
Sponsored by: Netflix
This was never documented, and isn't needed, so it's best removed to
avoid confusion.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18460
Make the pointers we pass into the commands const, also make the
linker set mirrors const.
Suggested by: cem@
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18459
o Dynamically load all the .so files found in /libexec/nvmecontrol and
/usr/local/libexec/nvmecontrol.
o Link nvmecontrol -rdynamic so that its symbols are visible to the
libraries we load.
o Create concatinated linker sets that we dynamically expand.
o Add the linked-in top and logpage linker sets to the mirrors for them
and add those sets to the mirrors when we load a new .so.
o Add some macros to help hide the names of the linker sets.
o Update the man page.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18455
fold
This was a typo for wdc. Eliminate it since it was in error. People
should use either 'wdc' or 'hgst' for the vendor from now on. 'hgst'
works for all versions this functionality is present for.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18403
Move the Intel specific log pages (including the one that samsung
implements) to intel.c. Add comment to the samsung vendor that it will
be going away soon.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18403
Eliminage redundant spaces and nvmecontrol at start of all the usage
strings. Update the usage printing code to add them back when
presenting to the user. Allow multi-line usage messages and print
proper leading spaces for lines starting with a space.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18403
Provide a usage() function that takes a struct nvme_function pointer
and produces a usage mssage. Eliminate all now-redundant usage
functions. Propigate the new argument through the program as needed.
Use common routine to print usage.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18403
If the dispatched function doesn't exit, then we get can get a
spurious function not found message. They all do exit, but this is a
little cleaner.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18403
These are all hgst/wdc specific, so move them into the wdc.c to live
with the wdc command.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18403
For the upcoming move of vendor specific code into vendor specific
files, make the common logpage routines global and move them to
nvmecontrol.h.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18403
Move logpage function def to header. Convert all the logpage_function
elements to elements of the linker set. Leave them all in logpage.c
for the moment.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18403
More commands will be added to nvmecontrol. Also, there will be a few
more vendor commands (some of which may need to remain private to
companies writing them). The first step on that journey is to move to
using linker sets to dispatch commands. The next step will be using
dlopen to bring in the .so's that have the command that might need
to remain private for seamless integration.
Similar changes to this will be needed for vendor specific log pages.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D18403
The original NVMe API used bit-fields to represent fields in data
structures defined by the specification (e.g. the op-code in the command
data structure). The implementation targeted x86_64 processors and
defined the bit fields for little endian dwords (i.e. 32 bits).
This approach does not work as-is for big endian architectures and was
changed to use a combination of bit shifts and masks to support PowerPC.
Unfortunately, this changed the NVMe API and forces #ifdef's based on
the OS revision level in user space code.
This change reverts to something that looks like the original API, but
it uses bytes instead of bit-fields inside the packed command structure.
As a bonus, this works as-is for both big and little endian CPU
architectures.
Bump __FreeBSD_version to 1200081 due to API change
Reviewed by: imp, kbowling, smh, mav
Approved by: imp (mentor)
Differential Revision: https://reviews.freebsd.org/D16404
Rename print_controller to nvme_print_controller. Put it in its
own file for easy inclusion. Move util.c to be nc_util.c to not
conflict with camcontrol. add nvecontrol_ext.h to define shared
interfaces.
Sponsored by: Netflix
Differential Revision: https://reviews.freebsd.org/D15371