- Updates tables in affected files with new entries from newer spec
revisions of SFF-8472, SFF-8024, and SFF-8636
- Change ifconfig to read and display the extended compliance code for
SFP media if the extended compliance code is not 0. This was being displayed
for QSFP transceivers only, but SFP28 media uses this to report 25G
capability.
Reviewed by: melifaro, sbruno
Sponsored by: Intel Corporation
Differential Revision: https://reviews.freebsd.org/D13286
The standards in the QSFP diagnostics area are not clear when the
additional measurements are present or not. Use a valid temperature
reading as an indicator for the presence of voltage and TX/RX power
measurements.
MFC after: 1 week
Sponsored by: Mellanox Technologies
Tested by: Netflix
Differential Revision: https://reviews.freebsd.org/D5391
Reviewed by: gallatin
on "ifconfig -v". I've seen no measurable timing difference
for doing additional SIOCGI2C call for system with 4k vlans.
* Determine appropriate handler (SFP/QSFP) by reading identification
byte (which is the same for both SFF-8472 and SFF-8436) instead
of checking driver name.
MFC with: r270064
Sponsored by: Yandex LLC
* Convert ixgbe to use this ioctl
* Convert ifconfig to use generic i2c handler for "ix" interfaces.
Approved by: Eric Joyner (ixgbe part)
MFC after: 2 weeks
Sponsored by: Yandex LLC
QSFP+ data via i2c inteface. These constants has been taken
from SFF-8436 "QSFP+ 10 Gbs 4X PLUGGABLE TRANSCEIVER" standard
rev 4.8.
* Add support for printing QSFP+ information from 40G NICs
such as Chelsio T5.
This commit does not contain ioctl changes necessary for this
functionality work, there will be another commit soon.
Example:
cxl1: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500
options=ec07bb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,.....>
ether 00:07:43:28:ad:08
nd6 options=29<PERFORMNUD,IFDISABLED,AUTO_LINKLOCAL>
media: Ethernet 40Gbase-LR4 <full-duplex>
status: active
plugged: QSFP+ 40GBASE-LR4 (MPO Parallel Optic)
vendor: OEM PN: OP-QSFP-40G-LR4 SN: 20140318001 DATE: 2014-03-18
module temperature: 64.06 C voltage: 3.26 Volts
lane 1: RX: 0.47 mW (-3.21 dBm) TX: 2.78 mW (4.46 dBm)
lane 2: RX: 0.20 mW (-6.94 dBm) TX: 2.80 mW (4.47 dBm)
lane 3: RX: 0.18 mW (-7.38 dBm) TX: 2.79 mW (4.47 dBm)
lane 4: RX: 0.90 mW (-0.45 dBm) TX: 2.80 mW (4.48 dBm)
Tested on: Chelsio T5
Tested on: Mellanox/Huawei passive/active cables/transceivers.
MFC after: 2 weeks
Sponsored by: Yandex LLC
presenting most interesting fields via ifconfig -v.
This version supports Intel ixgbe driver only.
Tested on: Cisco,Intel,Mellanox,ModuleTech,Molex transceivers
MFC after: 2 weeks