unmodified for ATAPI type devices with ports/sysutils/cdrtools.
(But we need timeout routine which was in kern/58649 for fixate, I think.)
PR: kern/58649
Submitted by: SAKIYAMA Nobuo <sakichan@sakichan.org>
receive 6 byte commands. Add a check for this flag to da(4) and cd(4) so
that they honor it. This is a quick workaround for many devices (especially
USB) that require da(4) quirks to operate. The more complete approach is
to finish the new transport code which will be aware of the SCSI version a
transport implements.
MFC after: 1 day
all of the Optio series have the same problems. It might be a better
approach eventually to add wildcard support to USB quirks.
PR: kern/50271, kern/46369
Approved by: re (rwatson)
The former fakes a valid response to an inquiry command. (I am completely
blown away that there are devices which hang upon receiving inquiry). The
latter returns "invalid request" to any inquiry commands with EVPD set.
NO_INQUIRY implies NO_INQUIRY_EVPD but not vice versa. Both quirks have been
tested separately on my USB key although it didn't require either of them.
While I'm here, fix wildcarding so that any/all of vendor, product, revision
can be wildcarded.
Idea from: Linux
MFC after: 2 weeks
use the underlying AsahiOptical USB chip and thus this quirk may need to
be generalized in the future.
PR: kern/46369
Submitted by: Tim Vanderhoek <vanderh@ecf.utoronto.ca>
MFC After: 3 days
in geom_disk.c.
As a side effect this makes a lot of #include <sys/devicestat.h>
lines not needed and some biofinish() calls can be reduced to
biodone() again.
a number of related problems along the way.
- Automatically detect CDROM drives that can't handle 6 byte mode
sense and mode select, and adjust our command size accordingly.
We have to handle this in the cd(4) driver (where the buffers are
allocated), since the parameter list length is different for the
6 and 10 byte mode sense commands.
- Remove MODE_SENSE and MODE_SELECT translation removed in ATAPICAM
and in the umass(4) driver, since there's no way for that to work
properly.
- Add a quirk entry for CDROM drives that just hang when they get a 6
byte mode sense or mode select. The reason for the quirk must be
documented in a PR, and all quirks must be approved by
ken@FreeBSD.org. This is to make sure that we fully understand why
each quirk is needed. Once the CAM_NEW_TRAN_CODE is finished, we
should be able to remove any such quirks, since we'll know what
protocol the drive speaks (SCSI, ATAPI, etc.) and therefore whether
we should use 6 or 10 byte mode sense/select commands.
- Change the way the da(4) handles the no_6_byte sysctl. There is
now a per-drive sysctl to set the minimum command size for that
particular disk. (Since you could have multiple disks with
multiple requirements in one system.)
- Loader tunable support for all the sysctls in the da(4) and cd(4)
drivers.
- Add a CDIOCCLOSE ioctl for cd(4) (bde pointed this out a long
time ago).
- Add a media validation routine (cdcheckmedia()) to the cd(4)
driver, to fix some problems bde pointed out a long time ago. We
now allow open() to succeed no matter what, but if we don't detect
valid media, the user can only issue CDIOCCLOSE or CDIOCEJECT
ioctls.
- The media validation routine also reads the table of contents off
the drive. We use the table of contents to implement the
CDIOCPLAYTRACKS ioctl using the PLAY AUDIO MSF command. The
PLAY AUDIO TRACK INDEX command that we previously used was
deprecated after SCSI-2. It works in every SCSI CDROM I've tried,
but doesn't seem to work on ATAPI CDROM drives. We still use the
play audio track index command if we don't have a valid TOC, but
I suppose it'll fail anyway in that case.
- Add _len() versions of scsi_mode_sense() and scsi_mode_select() so
that we can specify the minimum command length.
- Fix a couple of formatting problems in the sense printing code.
MFC after: 4 weeks
some USB devices. (Make sure to set xfer data length when we force
a short inquiry.)
Obtained from: NetBSD(sys/dev/usb/umass_scsipi.c rev.1.8)
Original idea from: Shingo WATANABE <nabe@nabechan.org>
not < the size of the device. This avoids geom complaints.
Fix a serious bug in the handling of the RS_NO_CLEAR_UA quirk. When we
go and insert the test-unit-ready command the umass_cam_quirk_cb() function
sets the status as if the READ_CAPACITY command suceeded when, in fact, it
did not. This leads to the CAM layer trying to use garbage in the return
buffer and panicing the system (or doing other bad things).
Add a quirk entry for MSYSTEMS DISK-ON-KEY, which is sold under the Sony
brand as a solid state disk-on-key usb device. This device requires
several quirks to work properly.
Note that the disk-on-key device will not work properly until CAM also
gets a quirk entry for it, which has been submitted to the CAM maintainer,
and you may have to temporarily uncomment the DELAY() as well. -current
does not properly wait for devices to power up so you may also have
to temporarily uncomment the DELAY(300000) to make your device work.
A solution must be found to that issue.
MFC after: 3 days
X-MFC note: the quirk support must MFCd before this patch can be
debugging levels to off by default. Now that debug levels can be
tweaked by sysctl we don't need to go through hoops to get the
different usb parts to produce debug data.
time we tell CAM to rescan the bus. Together with the previous patch
this should avoid the problem where the devices would wedge because they
got spoken to over two different pipes.
Tested by: Tomas Pluskal <plusik@pohoda.cz>
attachment after boot in some cases where the device gets confused if
spoken to over two different pipes simultaneously (resulting in TIMEOUT
errors on requesting INQUIRY data).
This solution is far from perfect, as after umass_attach has returned
the USB stack fetches the string descriptors in order for creating the
event that is sent to userland. It just makes the chances of collisions
less likely.
Tested by: Tomas Pluskal <plusik@pohoda.cz>
stead of after
2) Honour NO_TEST_UNIT_READY quirk for atapi devices as well
3) Actually support FujiFilm FinePix 6800 camera's. Will very likely also
work for other FinePix models.
Based on a debug session about half a year ago with Nik Hibma.
MFC after: 2 weeks
date: 2000/02/29 21:37:01; author: augustss; state: Exp;
Distinguish between device and interface classes.
(I finally found a document that said that they were different.)