The negative value was not expected and generated the low 8 bits as a byte,
which may be an invalid character encoding.
The final shift in creating the negative value was undefined as well.
Make the temporary variable unsigned to fix this.
Fix shifts of possibly negative numbers found with ubsan and avoid signed
integer overflow when hashing an extremely long command name.
MFC after: 1 week
Off by default, build behaves normally.
WITH_META_MODE we get auto objdir creation, the ability to
start build from anywhere in the tree.
Still need to add real targets under targets/ to build packages.
Differential Revision: D2796
Reviewed by: brooks imp
interactive.
I added the interactive check in r208881 to be safe, but in actual use
(scripts in set -m mode) passing along SIGINT seems best.
Discussed with: bdrewery
The parser considered 'trap exit INT' to reset the default for both EXIT and
INT. This beahvior is not POSIX compliant. This was avoided if a value was
specified for 'exit', but then disallows exiting with the signal received. A
possible workaround is using ' exit'.
However POSIX does allow this type of behavior if the parameters are all
integers. Fix the handling for this and clarify its support in the manpage
since it is specifically allowed by POSIX.
Differential Revision: https://reviews.freebsd.org/D2325
Reviewed by: jilles
MFC after: 2 weeks
EXP_REDIR was supposed to generate pathnames in redirection if exactly one
file matches, as permitted but not required by POSIX in interactive mode. It
is unlikely this will be implemented.
No functional change is intended.
MFC after: 1 week
Commands like 'export -p', 'set' and 'trap', and tracing enabled via 'set
-x' generate output suitable as shell input by adding quotes as necessary.
If there are control characters other than newline or invalid UTF-8
sequences, use $'...' and \OOO to display them safely.
The resulting output is not parsable by a strict POSIX.1-2008 shell but sh
from FreeBSD 9.0 and newer and many other shells can parse it.
Per Austin Group issue #459, shifting zero positional parameters may or may
not be considered an operand error (which causes the shell to exit in most
cases).
EXP_REDIR was not being checked for while expanding positional parameters in
redirection, so CTL* bytes were not being prefixed where they should be.
MFC after: 1 week
POSIX does not permit to continuing a getopts loop with different
arguments. For parsing the positional parameters, we handle this case by
resetting the getopts state when the positional parameters are changed in
any way (and the getopts state is local to a function). However, in the
syntax getopts <optstring> <var> <arg...>, changes could lead to invalid
memory access.
In the syntax getopts <optstring> <var> <arg...>, store a copy of the
arguments and continue to use them until getopts is reset.