they occur.
This prevents repeated notifications of the same event.
Status of these events may be viewed at any time by viewing the
SMART/Health Info Page using nvmecontrol, whether or not asynchronous
events notifications for those events are enabled. This log page can
be viewed using:
nvmecontrol logpage -p 2 <ctrlr id>
Future enhancements may re-enable these notifications on a periodic basis
so that if the notified condition persists, it will continue to be logged.
Sponsored by: Intel
Reviewed by: carl
Approved by: re (hrs)
MFC after: 1 week
when calculating stats in nvmecontrol perftest.
Sponsored by: Intel
Reported by: Joe Golio <joseph.golio@emc.com>
Reviewed by: carl
Approved by: re (hrs)
MFC after: 1 week
The previous method was to set the D_UNMAPPED_IO flag in the cdevsw
for the driver. The problem with this is that in many cases (e.g.
sa(4)) there may be some instances of the driver that can handle
unmapped I/O and some that can't. The isp(4) driver can handle
unmapped I/O, but the esp(4) driver currently cannot. The cdevsw
is shared among all driver instances.
So instead of setting a flag on the cdevsw, set a flag on the cdev.
This allows drivers to indicate support for unmapped I/O on a
per-instance basis.
sys/conf.h: Remove the D_UNMAPPED_IO cdevsw flag and replace it
with an SI_UNMAPPED cdev flag.
kern_physio.c: Look at the cdev SI_UNMAPPED flag to determine
whether or not a particular driver can handle
unmapped I/O.
geom_dev.c: Set the SI_UNMAPPED flag for all GEOM cdevs.
Since GEOM will create a temporary mapping when
needed, setting SI_UNMAPPED unconditionally will
work.
Remove the D_UNMAPPED_IO flag.
nvme_ns.c: Set the SI_UNMAPPED flag on cdevs created here
if NVME_UNMAPPED_BIO_SUPPORT is enabled.
vfs_aio.c: In aio_qphysio(), check the SI_UNMAPPED flag on a
cdev instead of the D_UNMAPPED_IO flag on the cdevsw.
sys/param.h: Bump __FreeBSD_version to 1000045 for the switch from
setting the D_UNMAPPED_IO flag in the cdevsw to setting
SI_UNMAPPED in the cdev.
Reviewed by: kib, jimharris
MFC after: 1 week
Sponsored by: Spectra Logic
As part of this commit, add an nvme_strvis() function which borrows
heavily from cam_strvis(). This will allow stripping of
leading/trailing whitespace and also handle unprintable characters
in model/serial numbers. This function goes into a new nvme_util.c
file which is used by both the driver and nvmecontrol.
Sponsored by: Intel
Reviewed by: carl
MFC after: 3 days
Recent testing with QEMU that has variable sector size support for
NVMe uncovered some of these issues. Chatham prototype boards supported
only 512 byte sectors.
Sponsored by: Intel
Reviewed by: carl
MFC after: 3 days
commands during controller initialization.
DELAY() does not work here during config_intrhook context - we need to
explicitly relinquish the CPU for the admin command completion to
get processed.
Sponsored by: Intel
Reported by: Adam Brooks <adam.j.brooks@intel.com>
Reviewed by: carl
MFC after: 3 days
and firmware revision in the controller's identify structure.
Also modify consumers of these fields to ensure they only use the
specified number of bytes for their respective fields.
Sponsored by: Intel
Reviewed by: carl
MFC after: 3 days
a new firmware command.
NVMe controllers may support up to 7 firmware slots for storing of
different firmware revisions. This new firmware command supports
firmware replacement (i.e. firmware download) with or without immediate
activation, or activation of a previously stored firmware image. It
also supports selection of the firmware slot during replacement
operations, using IDENTIFY information from the controller to
check that the specified slot is valid.
Newly activated firmware does not take effect until the new controller
reset, either via a reboot or separate 'nvmecontrol reset' command to the
same controller.
Submitted by: Joe Golio <joseph.golio@emc.com>
Obtained from: EMC / Isilon Storage Division
MFC after: 3 days
max transfer size. This guards against rogue commands coming in from
userspace.
Also add KASSERTS for the virtual address and unmapped bio cases, if the
transfer size exceeds the controller's max transfer size.
Sponsored by: Intel
MFC after: 3 days
Also allow admin commands to transfer up to this maximum I/O size, rather
than the artificial limit previously imposed. The larger I/O size is very
beneficial for upcoming firmware download support. This has the added
benefit of simplifying the code since both admin and I/O commands now use
the same maximum I/O size.
Sponsored by: Intel
MFC after: 3 days
This includes a new IOCTL to support a generic method for nvmecontrol(8) to pass
IDENTIFY, GET_LOG_PAGE, GET_FEATURES and other commands to the controller, rather than
separate IOCTLs for each.
Sponsored by: Intel
These were added early on for benchmarking purposes to avoid the mapped I/O
penalties incurred in kern_physio. Now that FreeBSD (including kern_physio)
supports unmapped I/O, the need for these NVMe-specific routines no longer exists.
Sponsored by: Intel
NULL. This simplifies decisions around if/how requests are routed through
busdma. It also paves the way for supporting unmapped bios.
Sponsored by: Intel
later found to not be usable because the controller doesn't support the
same number of queues.
This is not the normal case, but does occur with the Chatham prototype
board.
Sponsored by: Intel
mechanism.
Now that all requests are timed, we are guaranteed to get a completion
notification, even if it is an abort status due to a timed out admin
command.
This has the effect of simplifying the controller and namespace setup
code, so that it reads straight through rather than broken up into
a bunch of different callback functions.
Sponsored by: Intel
Reviewed by: carl
start or reset. Also add a notifier for NVMe consumers for controller fail
conditions and plumb this notifier for nvd(4) to destroy the associated
GEOM disks when a failure occurs.
This requires a bit of work to cover the races when a consumer is sending
I/O requests to a controller that is transitioning to the failed state. To
help cover this condition, add a task to defer completion of I/Os submitted
to a failed controller, so that the consumer will still always receive its
completions in a different context than the submission.
Sponsored by: Intel
Reviewed by: carl
This is just as effective, and removes the need for a bunch of admin commands
to a controller that's going to be disabled shortly anyways.
Sponsored by: Intel
Reviewed by: carl
start process.
The spec indicates the OS driver should use Set Features (Software
Progress Marker) to set the pre-boot software load count to 0
after the OS driver has successfully been initialized. This allows
pre-boot software to determine if there have been any issues with the
OS loading.
Sponsored by: Intel
Reviewed by: carl
This flag was originally added to communicate to the sysctl code
which oids should be built, but there are easier ways to do this. This
needs to be cleaned up prior to adding new controller states - for example,
controller failure.
Sponsored by: Intel
Reviewed by: carl
The controller's IDENTIFY data contains MDTS (Max Data Transfer Size) to
allow the controller to specify the maximum I/O data transfer size. nvme(4)
already provides a default maximum, but make sure it does not exceed what
MDTS reports.
Sponsored by: Intel
Reviewed by: carl
that if a specific I/O repeatedly times out, we don't retry it indefinitely.
The default number of retries will be 4, but is adjusted using hw.nvme.retry_count.
Sponsored by: Intel
Reviewed by: carl
specified log page.
This satisfies the spec condition that future async events of the same type
will not be sent until the associated log page is fetched.
Sponsored by: Intel
Reviewed by: carl
NVMe error log entries include status, so breaking this out into
its own data structure allows it to be included in both the
nvme_completion data structure as well as error log entry data
structures.
While here, expose nvme_completion_is_error(), and change all of
the places that were explicitly looking at sc/sct bits to use this
macro instead.
Sponsored by: Intel
Reviewed by: carl