The source of error is a rounded increment being too large and thus the loop
steps slightly past 'last'. Perform a final comparison using the formatted
string values (truncated precision) to determine if we still need to print
the 'last' value.
PR: 217149
Submitted by: Fernando Apesteguía <fernando.apesteguia AT gmail.com>,
Yuri Pankov <yuripv AT icloud.com> (earlier version)
Reported by: Martijn Dekker <mcdutchie AT hotmail.com>
Sponsored by: Dell EMC Isilon
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.
The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
No functional change intended.
Off by default, build behaves normally.
WITH_META_MODE we get auto objdir creation, the ability to
start build from anywhere in the tree.
Still need to add real targets under targets/ to build packages.
Differential Revision: D2796
Reviewed by: brooks imp