849 Commits

Author SHA1 Message Date
ru
4da77db3b2 Add an example of how to set up a 3-wire serial terminal.
Usually, getty(8) does the trick, but if you just need a
serial console without getty(8), here's how.
2006-03-23 08:48:38 +00:00
flz
f6add5dd6c - Replace awk parts with shell.
Approved by:	brooks
MFC after:	2 weeks
2006-03-20 18:00:14 +00:00
ru
388e590f95 Reimplementation of world/kernel build options. For details, see:
http://lists.freebsd.org/pipermail/freebsd-current/2006-March/061725.html

The src.conf(5) manpage is to follow in a few days.

Brought to you by:	imp, jhb, kris, phk, ru (all bugs are mine)
2006-03-17 18:54:44 +00:00
des
32c951cbb3 This script symlinks /boot/kernel to the directory that contains the kernel
you booted from, unless /boot/kernel already exists and is not a symlink.
This should only affect people like me who juggle multiple kernels and
have KODIR = /boot/${KERN_IDENT} in /etc/make.conf to keep them apart.
2006-03-17 16:28:12 +00:00
emax
f1994b9421 Reorganize /etc/rc.d/syscons and move all keyboard related settings
into one function syscons_configure_keyboard(). Call new function from
both syscons_start() and sysconst_setkeyboard(). The reason for this
is because syscons_start() will (re)configure both keyboard and screen
settings. Apparently, some graphics cards have problems with running
vidcontrol(1) while X11 is running.

Remove "/etc/rc.d/syscons restart" from /etc/devd.conf. It is no longer
required. Using "/etc/rc.d/syscons setkeyboard" is enough. This also
should fix annoying "syscons not running?" message.

Tested by:	Ulrich Spoerlein < q at galgenberg dot net >
MFC after:	3 days
2006-03-16 17:42:28 +00:00
fjoe
74880d1ae0 Fix overriding jail_list from command line.
MFC after:	3 days
2006-03-08 20:40:37 +00:00
emax
2c76f6757e Add new 'setkeyboard' method to the /etc/rc.d/syscons. It accepts the
keyboard device name (i.e. /dev/kbd0). This method will do nothing is
kbdmux(4) is the current active keyboard, otherwise it will switch
active keyboard as requested.

Modify ukbd(4) entries in the /etc/devd.conf to use /etc/rc.d/syscons
and new 'setkeyboard' method.

No comments from:	freebsd-current@
MFC after:		1 day
2006-03-06 06:38:34 +00:00
wkoszek
f23b544905 Use 'ipfw list' instead of 'ipfw l', since it's deprecated (and warning is
printed on system startup).

Approved by:	cognet (mentor)
MFC after:	3 days
2006-02-26 16:45:29 +00:00
dougb
d07e9ef4b2 Make sure abi (and therefore archdep) start before SERVERS as part of
the ongoing re-alignment of ordering that is necessary as a result of
including local scripts in the base rcorder. [1]

Accomplish this by removing the BEFORE's, and using REQUIRE instead.
This makes the dependencies more obvious, and less susceptible to turning
circular and/or nonsensical when seemingly innocent changes are made
in one place and not another.

Requested by:	delphij [1]
2006-02-19 08:18:48 +00:00
ru
2f299d4119 Check if /sbin/nextboot exists before running it.
PR:		93466
Submitted by:	Mats Palmgren
2006-02-17 08:34:01 +00:00
marcel
279b470f55 On ia64, the unaligned_print sysctl is a debugging knob under debug
and not under machdep as the behaviour is controlled by the process.
When PSR.ac is set the process expects to receive a SIGBUS. Otherwise
the processor or the kernel will emulate the misaligned memory access.

MFC after: 3 days
2006-02-13 21:41:32 +00:00
imp
1be9da7b7f Since OLDCARD is gone from the kernel, catchup here and remove support
from here as well.
2006-02-13 20:08:31 +00:00
dougb
2a1b618d7b Overhaul the named boot script:
1. Remove a now-spurious NetBSD CVS Id, as we are no longer synching work
2. Remove a now-spurious BEFORE, since ntpdate now REQUIRE's named
3. Replace the call to set rcvar with what that function would output,
and generally reduce indirection ($name -> named) since it's highly
unlikely the name of the named process or service will change any time soon.
4. Resort the order the variables at the top of the file to a more
traditional format, and remove a spurious required_dirs from the top, as it
works better after load_rc_config.
5. We do not want the default reload method with named, so define a simple
but appropriate substitute using rndc. If I were writing this script for
the first time I would not include this at all, since it's preferable to
control a running daemon with rndc to start with, but given that this is
already here, let's do it right. I hope that future generations will
however resist the tempation to add reconfig to extra_commands.
6. By the same token, we want to use rndc to shut down named, but given
that by defining a stop function we lose the "find the process by its
pid file in an emergency" goodness of rc.subr, try to do something useful
in the event that rndc is not available, and keep the user informed.
7. Replace some "test -f" with "test -r" to handle the unlikely event
that the relevant file exists, but is unreadable.
8. Twiddle whitespace in a few areas, remove a spurious blank line,
a bogus double space, and try to do better indenting.
9. Improve generation of the rndc.key file significantly
a. If for some reason a user has an rndc.conf file, assume that they
did that on purpose, and hence know what they are doing, so leave them alone.
b. Introduce a named_uid configuration variable so that the user which owns
the rndc.key file and the user named runs as always match, and is more
easily configurable. This should dramatically reduce problems with rndc.
c. Also test that the rndc.key file size is greater than zero, rather than
simply that the file exists. I have seen at least one user report this exact
problem, and although neither of us is sure where the empty file came from,
the fix is simple, so include it.
d. Rather than try to create an rndc.key file in both /etc/namedb and the
chroot'ed /etc/namedb, assume that they are be the same (which they should
be), and only create the file in the chroot'ed version of the directory.
This partially addresses the problem described in conf/73929, but I have
not yet finished thinking about the PREFIX issue that PR also raises.

As a result of introducing the named_uid knob, the default named_flags
are now empty.

Update defaults/rc.conf and rc.conf(5) to reflect these changes.
2006-02-13 08:45:51 +00:00
matteo
609d51b24f Make localpkg print local scripts names when the boot is verbose
PR:		conf/68525
Approved by:	philip (mentor)
MFC after:	3 days
2006-02-12 10:04:56 +00:00
mlaier
1bebb42407 pflog is a separate module now.
Submitted by:	Antoine Brodin
PR:		kern/88271
MFC after:	1 week
2006-02-05 22:38:08 +00:00
flz
06bbcb2dd7 - Add a startup script for hostapd.
- Document associated variable in rc.conf(5).

Approved by:	dougb
MFC after:	1 week
2006-02-03 01:35:36 +00:00
rwatson
4a1c13c118 Add auditd rc.d script.
Submitted by:	trhodes
Obtained from:	TrustedBSD Project
2006-02-02 10:02:55 +00:00
netchild
b9239b94b7 As a quick fix disable the update of the linux ld.so.cache file, since
currently it grabs some FreeBSD native libs too.

A final solution is under discussion with brooks.
2006-01-24 18:58:48 +00:00
pjd
7ae11fdb19 The 'reload' command did the same as 'restart' command.
Allow user to decide if SAD and SPD entries should be flushed on 'reload'.
With this change flush/spdflush is not done automatically (it could still
be done from ipsec.conf).
2006-01-24 15:16:55 +00:00
pjd
0af7bce7e6 Remove stale comment.
This change should be made in rev1.9.

MFC after:	1 week
2006-01-24 15:12:44 +00:00
pjd
633461c588 Use $ipsec_file instead of hardcoded /etc/ipsec.conf.
This change should be made in rev1.2.

MFC after:	1 week
2006-01-24 15:11:11 +00:00
yar
e9ad335f2d Add an rc.d script for stand-alone ftpd.
Document the script's controls on the rc.conf(5)
manpage and touch its Dd.

PR:		conf/90893
MFC after:	5 days
2006-01-21 18:08:16 +00:00
matteo
33d3c223da Allow the use of wildcarded device names in devfs.conf
PR:		conf/90760
Submitted by:	Darren Pilgrim <darren.pilgrim@gmail.com>
Approved by:	philip (mentor)
2006-01-21 14:31:45 +00:00
wes
9455e2dc0d Tell nextboot to clean up after itself. 2006-01-18 04:53:48 +00:00
philip
00ce0e8a4a Remove the module loading magic again; it's not needed after all.
Pointy hat to:	matteo
Submitted by:	matteo
Reviewed by:	pjd
MFC after:	3 days
2006-01-17 19:29:31 +00:00
philip
528140c6f2 Load the g_md kernel module if needed.
Pointed out by:	Gianmarco Giovannelli
Submitted by:	matteo
MFC after:	3 days
2006-01-16 13:26:05 +00:00
dougb
8961e0fe8a REQUIRE named. On all systems I've examined running HEAD and
RELENG_6 this will be a noop, however as we introduce local
startup scripts to the base rcorder, we'll see more cases
where the previous status quo will need to be made explicit
to avoid having it disrupted when random local scripts are
added to the mix.
2006-01-16 06:03:42 +00:00
ceri
a415f589c8 Marius Nuennerich pointed out that nextboot(8) configured boot options
were now sticky.  This script was deleting /boot/nextkernel on boot, but
there is no code in the tree that creates that file since revision 1.15
of src/sbin/reboot/reboot.c.
nextboot(8) creates /boot/nextboot.conf, so remove that instead.

Approved by:	jhb (proxy mentor)
MFC after:	1 week
2006-01-15 23:12:26 +00:00
brooks
b818dbf010 Be a little more read-only file system friendly when running the Linux
ldconfig.  Build the cache in a temporary directory and only install it
if it's actually different that the installed one.

Also, use "cat tmp > real" to install the temporary file in the real
location to allow the real location to be a symlink to a writable
directory such as /var/run (where the file actually belongs).

MFC After:	5 days
2006-01-11 21:30:41 +00:00
dougb
2bdeba9d87 Add a mechanism to include files added by ports which contain
the names of directories to include in the base ldconfig script.
This will eliminate the need for each port to install its own
boot script which does nothing but ldocnfig a given directory.

This code was developed by flz (ports committer), discussed on
freebsd-rc@, and modified slightly by me.

Submitted by:	flz
Reviewed by:	brooks
2006-01-08 10:15:31 +00:00
rse
f298c45195 1. Add missing semicolon between "warn" and "return" to make sure
the line continuation backslash doesn't cause "warn" to print "return".
2. Group "warn" and "return" together as the "return 1" should be
   performed only if the "kldload nfsclient" also failed (and not
   already if the "vfs.nfs" sysctl(8) check failed).

MFC after: 3 days
2005-12-30 09:16:23 +00:00
rse
51a6864846 Remove superfluous line continuation backslash.
MFC after: 3 days
2005-12-30 08:57:33 +00:00
dougb
5e13600953 Fix another braino, don't remove the X related socket directories
right after creating them.

Twiddle whitespace while I'm here.
2005-12-27 23:22:18 +00:00
dougb
761b74bc75 Make sure that the prestart routine is run with *start, instead of
just 'start'.

Reminded by:	keramida
2005-12-27 23:08:58 +00:00
dougb
2bb58e1702 syslogd should REQUIRE newsyslog, rather than newsyslog using
BEFORE: syslogd. This does not produce any change in the
ordering at the moment, but is cleaner style for the long term.
2005-12-21 09:54:15 +00:00
dougb
41ec533c29 Several users have commented (via filing PRs) that having ntp* depend
on devfs is useful so that a hardware time device can start with its
necessary device nodes already in place. While this ordering happens
as a side effect currently in HEAD, and the PRs were generally fixed
via upgrades, etc; it's better to make it explicit.

While I'm here, ntpd should REQUIRE ntpdate, rather than ntpdate
using BEFORE: ntpd.
2005-12-21 09:48:41 +00:00
dougb
0be5d450a6 REQUIRE: syslogd and BEFORE: NETWORKING are now antithetical,
and including both in this file had nasty side effects on the
ordering of syslogd, as well as producing an error when running
rcorder. Remove the more bogus of the two options, which restores
proper ordering and removes the error.

There is an open question as to whether scripts with the nostart
KEYWORD should even have REQUIRE/BEFORE lines, and indeed, whether
they should be in /etc/rc.d at all, but that's for another time.
2005-12-21 01:19:20 +00:00
dougb
d2867372db Include a somewhat hackish way to make sure that we *always* test the
new clear_tmp_X variable when start'ing.
2005-12-20 23:22:47 +00:00
dougb
5a09b5d83f Brooks pointed out a potential problem with disabling the X cleaning
by default, so add a new knob that is on by default, and check that
knob in start_precmd so that it can run even if cleaning /tmp is
not enabled. This has the advantage of not violating POLA, while
still allowing the user to disable this behavior if they wish (for
example on a server that will never run X).
2005-12-20 20:36:48 +00:00
dougb
c9292fd995 Clear up problems with /etc/rc.d/{abi|cleanvar|cleartmp} brought
to light by the PR.  Specifically, convert these three scripts
into good rc.d citizens, making sure that their functionality
is preserved, but the rc.d framework rules are not broken.

Add support for cleanvar as a regular rc.d script in the
default rc.conf, and document this in the man page.

Add a descriptive comment to rc.conf that regarding the
three emulation/compatibility services provided by abi
so users will not be confused by these services not having
their own startup scripts.

PR:		conf/84574
Submitted by:	Alexander Botero-Lowry
2005-12-19 10:57:00 +00:00
iedowse
0b71e714c9 Remove usbd(8) and all references to it. It is no longer necessary
since devd(8) now provides the same functionality.

Submitted by:	Anish Mistry
2005-12-15 01:04:51 +00:00
dougb
06a285042d Drop rcconf.sh now that it has been removed 2005-12-10 23:23:09 +00:00
dougb
156819c498 Remove rcconf.sh from /etc/rc.d, and instead load the configuration
as part of rc. Doing this, and the sourcing of rc.subr after we have
determined if we are booting diskless (and correspondingly run
rc.initdiskless if necessary) are safe, and actually allow fewer files
to be needed on the diskless box. This also allows variables from
the configuration to be available to rc itself, such as ...

Add a variable to rc.conf, early_late_divider, which designates the
script which separates the early and late stages of the boot process.
Default this to mountcritlocal, and add text to etc/defaults/rc.conf,
rc.conf(5) and diskless(8) which describes how and why one might want
to change this.

Reviewed by:	brooks
2005-12-10 20:21:46 +00:00
dougb
e948569c6b Use of REQUIRE is better than BEFORE for most scripts, and very
few scripts should have no REQUIRE at all.
2005-12-10 19:49:03 +00:00
brooks
863654c1a1 Don't bogusly depend on dhclient. It's now run either by
/etc/rc.d/netif or from devd rather than by the startup scripts.
2005-12-03 01:33:06 +00:00
ru
5211119761 "-o rw" is invalid and undocumented mount option that
is only present for fstab(5) compatibility, and is
otherwise ignored by mount(8) (not passed to mount_*
programs, and not passed to nmount(2)).

"-u -o rw" worked with an old mount(8) with mount_ufs.c
because "-o rw" was stripped and simple "-u" caused an
update of UFS from read-only to read-write, due to
inability of mount(2) to track changes in options
(MNT_RDONLY is either set or not).

"-u" no longer causes the transition from RO to RW,
now that mount(8) was converted to use nmount(2), so
an explicit change to RW is required.  Keep up with
this change, and use "-uw" to mount root read-write.
2005-12-02 21:33:43 +00:00
dougb
9ee5ec330f Brooks pointed out a case where tmp needs to be run after
mountcritremote, so force it the other way instead.
2005-12-02 20:35:23 +00:00
dougb
997405c1ca Introduce startup scripts from the local_startup directories to
the base rcorder. This is accomplished by running rcorder twice,
first to get all the disks mounted (through mountcritremote),
then again to include the local_startup directories.

This dramatically changes the behavior of rc.d/localpkg, as
all "local" scripts that have the new rc.d semantics are now
run in the base rcorder, so only scripts that have not been
converted yet will run in rc.d/localpkg.

Make a similar change in rc.shutdown, and add some functions in
rc.subr to support these changes.

Bump __FreeBSD_version to reflect this change.
2005-12-02 20:06:07 +00:00
dougb
f88100d008 Force this script to run before mountcritremote to avoid
non-deterministic behavior when introducing local_startup
scripts to rcorder.
2005-12-02 19:54:57 +00:00
emax
24ecba159a Remove not needed redirection of kldstat -q output to /dev/null.
Noticed by:	pjd
MFC after:	3 days
2005-11-22 19:17:41 +00:00