Add net.link.lagg.lacp.default_strict_mode which defines
the default value for LACP strict compliance for created
lagg devices.
Also:
* Add lacp_strict option to ifconfig(8).
* Fix lagg(4) creation examples.
* Minor style(9) fix.
MFC after: 1 week
netbsd-tests.test.mk (r289151)
- Eliminate explicit OBJTOP/SRCTOP setting
- Convert all ad hoc NetBSD test integration over to netbsd-tests.test.mk
- Remove unnecessary TESTSDIR setting
- Use SRCTOP where possible for clarity
MFC after: 2 weeks
Sponsored by: EMC / Isilon Storage Divison
Off by default, build behaves normally.
WITH_META_MODE we get auto objdir creation, the ability to
start build from anywhere in the tree.
Still need to add real targets under targets/ to build packages.
Differential Revision: D2796
Reviewed by: brooks imp
gif(4) interface. Add new option "ignore_source" for gif(4) interface.
When it is enabled, gif's encapcheck function requires match only for
packet's destination address.
Differential Revision: https://reviews.freebsd.org/D2004
Obtained from: Yandex LLC
MFC after: 2 weeks
Sponsored by: Yandex LLC
packets on tunnel interfaces. Add support of these ioctls to gre(4),
gif(4) and me(4) interfaces. For incoming packets M_SETFIB() should use
if_fib value from ifnet structure, use proper value in gre(4) and me(4).
Differential Revision: https://reviews.freebsd.org/D2462
No objection from: #network
MFC after: 2 weeks
Sponsored by: Yandex LLC
because a link where looped back NS messages are permanently observed
does not work with either NDP or ARP for IPv4.
- draft-ietf-6man-enhanced-dad is now RFC 7527.
Discussed with: hiren
MFC after: 3 days
- Extend the number of available subtypes for Ethernet media by using some
of the ifmedia word's option bits to help denote subtypes. As a result, the
number of possible Ethernet subtype values increases from 31 to 511.
- Use some of those new values to define new media types.
- lacp_compose_key() recgonizes the new Ethernet media types added.
(Change made as required by a comment in if_media.h)
- New ioctl, SIOGIFXMEDIA, to handle getting the new extended media types.
SIOCGIFMEDIA is retained for backwards compatibility.
- Changes to ifconfig to allow it to handle the new extended media types.
Submitted by: mike@karels.net (original), hselasky
Reviewed by: jfvogel, gnn, hselasky
Approved by: jfvogel (mentor), gnn (mentor)
Differential Revision: http://reviews.freebsd.org/D1965
- Use strlcpy() instead of strcpy().
- Use strlcat() instead of a strlcpy() with a magic number subtracted
from the length.
- Replace strncmp(..., strlen(foo) + 1) with strcmp(...).
Differential Revision: https://reviews.freebsd.org/D1814
Reviewed by: rpaulo
MFC after: 2 weeks
- Add no_dad and ignoreloop per-IF knob. no_dad disables DAD completely,
and ignoreloop is to prevent infinite loop in loopback probing state when
loopback is permanently expected.
Reverse the sorting order of the interfaces addresses familise so it should be
the same as getifaddrs(3) order. [2]
Suggested by: hrs [1], bz [2]
Approved by: hrs, bapt
based on the address family. This should help to recognize interfaces with
multiple AF (e.g. ipv4 and ipv6) with many aliases or additional addresses. The
order of addresses inside a single group is strictly preserved.
Improve the scope_id output for AF_INET6 families, as the
current approach uses hexadecimal string that is basically the ID of an
interface, whilst this information is already depicted by getnameinfo(3) call.
Therefore, now ifconfig just prints the scope of address as it is defined in
2.4 of RFC 2373.
PR: 197270
Approved by: bapt
MFC after: 2 weeks
OpenBSD; unsure why we chose to do so. As groups are a requirement for
pf, exposing them by default will make our pf implementation less
confusing.
While here add a missing free() that OpenBSD fixed 7 years ago.
PR: 194925
Differential Revision: https://reviews.freebsd.org/D1185
Approved by: des
Obtained from: OpenBSD
Split it into two modules: if_gre(4) for GRE encapsulation and
if_me(4) for minimal encapsulation within IP.
gre(4) changes:
* convert to if_transmit;
* rework locking: protect access to softc with rmlock,
protect from concurrent ioctls with sx lock;
* correct interface accounting for outgoing datagramms (count only payload size);
* implement generic support for using IPv6 as delivery header;
* make implementation conform to the RFC 2784 and partially to RFC 2890;
* add support for GRE checksums - calculate for outgoing datagramms and check
for inconming datagramms;
* add support for sending sequence number in GRE header;
* remove support of cached routes. This fixes problem, when gre(4) doesn't
work at system startup. But this also removes support for having tunnels with
the same addresses for inner and outer header.
* deprecate support for various GREXXX ioctls, that doesn't used in FreeBSD.
Use our standard ioctls for tunnels.
me(4):
* implementation conform to RFC 2004;
* use if_transmit;
* use the same locking model as gre(4);
PR: 164475
Differential Revision: D1023
No objections from: net@
Relnotes: yes
Sponsored by: Yandex LLC
vxlan creates a virtual LAN by encapsulating the inner Ethernet frame in
a UDP packet. This implementation is based on RFC7348.
Currently, the IPv6 support is not fully compliant with the specification:
we should be able to receive UPDv6 packets with a zero checksum, but we
need to support RFC6935 first. Patches for this should come soon.
Encapsulation protocols such as vxlan emphasize the need for the FreeBSD
network stack to support batching, GRO, and GSO. Each frame has to make
two trips through the network stack, and each frame will be at most MTU
sized. Performance suffers accordingly.
Some latest generation NICs have begun to support vxlan HW offloads that
we should also take advantage of. VIMAGE support should also be added soon.
Differential Revision: https://reviews.freebsd.org/D384
Reviewed by: gnn
Relnotes: yes
if_lagg(4) interfaces which were cloned in a vnet jail.
Sysctl nodes which are dynamically generated for each cloned interface
(net.link.lagg.N.*) have been removed, and use_flowid and flowid_shift
ifconfig(8) parameters have been added instead. Flags and per-interface
statistics counters are displayed in "ifconfig -v".
CR: D842
The FreeBSD is the only system that has the FEC protocol, that is a simple alias
to loadbalance protocol and does not implement the ancient Cisco FEC standard.
From now on, we remove the fec protocol from the documentation and keep the FEC
code only for compatibility.
Phabric: D539
Reviewed by: glebius, thompsa
Approved by: glebius
Sponsored by: QNAP Systems Inc.
and receives frames on any port of the lagg(4).
Phabric: D549
Reviewed by: glebius, thompsa
Approved by: glebius
Obtained from: OpenBSD
Sponsored by: QNAP Systems Inc.
It affects the IPv6 source address selection algorithm (RFC 6724)
and allows override the last rule ("longest matching prefix") for
choosing among equivalent addresses. The address with `prefer_source'
will be preferred source address.
Obtained from: Yandex LLC
MFC after: 1 month
Sponsored by: Yandex LLC
on "ifconfig -v". I've seen no measurable timing difference
for doing additional SIOCGI2C call for system with 4k vlans.
* Determine appropriate handler (SFP/QSFP) by reading identification
byte (which is the same for both SFF-8472 and SFF-8436) instead
of checking driver name.
MFC with: r270064
Sponsored by: Yandex LLC
* Convert ixgbe to use this ioctl
* Convert ifconfig to use generic i2c handler for "ix" interfaces.
Approved by: Eric Joyner (ixgbe part)
MFC after: 2 weeks
Sponsored by: Yandex LLC
QSFP+ data via i2c inteface. These constants has been taken
from SFF-8436 "QSFP+ 10 Gbs 4X PLUGGABLE TRANSCEIVER" standard
rev 4.8.
* Add support for printing QSFP+ information from 40G NICs
such as Chelsio T5.
This commit does not contain ioctl changes necessary for this
functionality work, there will be another commit soon.
Example:
cxl1: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500
options=ec07bb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,.....>
ether 00:07:43:28:ad:08
nd6 options=29<PERFORMNUD,IFDISABLED,AUTO_LINKLOCAL>
media: Ethernet 40Gbase-LR4 <full-duplex>
status: active
plugged: QSFP+ 40GBASE-LR4 (MPO Parallel Optic)
vendor: OEM PN: OP-QSFP-40G-LR4 SN: 20140318001 DATE: 2014-03-18
module temperature: 64.06 C voltage: 3.26 Volts
lane 1: RX: 0.47 mW (-3.21 dBm) TX: 2.78 mW (4.46 dBm)
lane 2: RX: 0.20 mW (-6.94 dBm) TX: 2.80 mW (4.47 dBm)
lane 3: RX: 0.18 mW (-7.38 dBm) TX: 2.79 mW (4.47 dBm)
lane 4: RX: 0.90 mW (-0.45 dBm) TX: 2.80 mW (4.48 dBm)
Tested on: Chelsio T5
Tested on: Mellanox/Huawei passive/active cables/transceivers.
MFC after: 2 weeks
Sponsored by: Yandex LLC