of upgrading older machines using ataraid(4) to newer releases.
This optional parameter is controlled via kern.geom.raid.legacy_aliases
and will create a /dev/ar0 device that will point at /dev/raid/r0 for
example.
Tested on Dell SC 1425 DDF-1 format software raid controllers installing from
stable/7 and upgrading to stable/9 without having to adjust /etc/fstab
Reviewed by: mav
Obtained from: Yahoo!
MFC after: 2 Weeks
when comparing its size with the size of the media, to determine if
the last disk block is unused.
Submitted by: Andreas Longwitz <longwitz@incore.de>
Reviewed by: pjd
MFC after: 2 weeks
provided by Bas Smeelen <b.smeelen@ose.nl>. Use of 'gpart list'
suggested by by Andrey V. Elsukov <ae@FreeBSD.org>.
PR: docs/174270
Submitted by: Ronald F.Guilmette <rfg@tristatelogic.com>
Reviewed by: ae (block sizes)
MFC after: 1 week
In addition to adding `static' where possible:
- bin/date: Move `retval' into extern.h to make it visible to date.c.
- bin/ed: Move globally used variables into ed.h.
- sbin/camcontrol: Move `verbose' into camcontrol.h and fix shadow warnings.
- usr.bin/calendar: Remove unneeded variables.
- usr.bin/chat: Make `line' local instead of global.
- usr.bin/elfdump: Comment out unneeded function.
- usr.bin/rlogin: Use _Noreturn instead of __dead2.
- usr.bin/tset: Pull `Ospeed' into extern.h.
- usr.sbin/mfiutil: Put global variables in mfiutil.h.
- usr.sbin/pkg: Remove unused `os_corres'.
- usr.sbin/quotaon, usr.sbin/repquota: Remove unused `qfname'.
defined by the SNIA Common RAID Disk Data Format Specification v2.0.
Supports multiple volumes per array and multiple partitions per disk.
Supports standard big-endian and Adaptec's little-endian byte ordering.
Supports all single-layer RAID levels. Dual-layer RAID levels except
RAID10 are not supported now because of GEOM RAID design limitations.
Some work is still to be done, but the present code already manages basic
interoperation with RAID BIOS of the Adaptec 1430SA SATA RAID controller.
MFC after: 1 month
Sponsored by: iXsystems, Inc.
- Implement "configure" command to allow switching operation mode of
running device on-fly without destroying and recreation.
- Implement Active/Read mode as hybrid of Active/Active and Active/Passive.
In this mode all paths not marked FAIL may handle reads same time,
but unlike Active/Active only one path handles write requests at any
point in time. It allows to closer follow original write request order
if above layers need it for data consistency (not waiting for requisite
write completion before sending dependent write).
- Hide duplicate messages about device status change.
- Remove periodic thread wake up with 10Hz rate.
MFC after: 2 weeks
Sponsored by: iXsystems, Inc.
reduce the size of the partition in the example from 128 blocks to 94
blocks so it will end on a 128-block boundary. Also remove the -b
option from the next example.
MFC after: 3 weeks
existing sections to refer to the new one. Rearrange partitioning scheme
list so MBR and EBR types are together. Also add several corrections for
grammar, clarity, and consistency.
Approved by: gjb (mentor)
MFC after: 1 week