- Store the length of each read-only VPD value since not all values are
guaranteed to be ASCII values (though most are).
- Add a new pciio ioctl to fetch VPD for a single PCI device. The values
are returned as a list of variable length records, one for the device
name and each keyword.
- Add a new -V flag to pciconf's list mode which displays VPD data for
each device.
MFC after: 1 week
bus driver will now remember the size of a BAR obtained during the initial
bus scan and use that size when doing lazy resource allocation rather than
resizing the BAR. The bus driver will now also report unallocated BARs to
userland for display by 'pciconf -lb'. Psuedo-resources that are not BARs
(such as the implicit I/O port resources for master/slave ATA controllers)
will no longer be listed as BARs in 'pciconf -lb'. During resume, BARs are
restored from their new saved state instead of having the raw registers
saved and restored across resume. This also fixes restoring BARs at
unusual loactions if said BAR has been allocated by a driver.
Add a constant for the offset of the ROM BIOS BAR in PCI-PCI bridges and
properly handle ROM BIOS BARs in PCI-PCI bridges. The PCI bus now also
properly handles the lack of a ROM BIOS BAR in a PCI-Cardbus bridge.
Tested by: jkim
Different sub-kinds of PCI buses may have different rules and
thus it is up for the bus backends to do proper input checks.
For example, PCIe allows configuration register numbers < 0x1000,
while for PCI proper the limit is 0x100.
And, in fact, the buses already do the checks.
Reviewed by: jhb
MFC after: 1 week
X-ToDo: add check for negative value to bus backends
X-ToDo: use named constant for maximum PCIe register
device. The details include the current value of the BAR (including all
the flag bits and the current base address), its length, and whether or not
it is enabled. Since this operation is not invasive, non-root users are
allowed to use it (unlike manual config register access which requires
root). The intention is that userland apps (such as Xorg) will use this
interface rather than dangerously frobbing the BARs from userland to
obtain this information.
- Add a new sub-mode to the 'list' mode of pciconf. The -b flag when used
with -l will now list all the active BARs for each device.
MFC after: 1 month
but reread it from the device_t every time the device list is fetched.
Previously the device name in pciconf -l would not be updated when a driver
was unloaded or if a device was detached and attached to a different
driver.
MFC after: 1 week
PR: kern/104777
Submitted by: "Iasen Kostoff" tbyte | otel net
- Use the correct offsets when copying out the results of PCIOCGETCONF_OLD.
This happened to not affect the 64-bit architectures because there the
addition of pc_domain to struct pcisel didn't change the overall size of
struct pci_conf. [1]
- Always copy the name and unit information to conf_old so it's also part
of the output once this information is cached in dinfo.
- Use the correct type for flags in struct pci_match_conf_old. This
change is more or less cosmetic though.
Reported and tested by: bde [1]
Reviewed by: imp
MFC after: 3 days
Committed from: 24C3
the PCIOCGETCONF, PCIOCREAD and PCIOCWRITE IOCTLs, which was broken
with the introduction of PCI domain support.
As the size of struct pci_conf_io wasn't changed with that commit,
this unfortunately requires the ABI of PCIOCGETCONF to be broken
again in order to be able to provide backwards compatibility to
the old version of that IOCTL.
Requested by: imp
Discussed with: re (kensmith)
Reviewed by: PCI maintainers (imp, jhb)
MFC after: 5 days
support machines having multiple independently numbered PCI domains
and don't support reenumeration without ambiguity amongst the
devices as seen by the OS and represented by PCI location strings.
This includes introducing a function pci_find_dbsf(9) which works
like pci_find_bsf(9) but additionally takes a domain number argument
and limiting pci_find_bsf(9) to only search devices in domain 0 (the
only domain in single-domain systems). Bge(4) and ofw_pcibus(4) are
changed to use pci_find_dbsf(9) instead of pci_find_bsf(9) in order
to no longer report false positives when searching for siblings and
dupe devices in the same domain respectively.
Along with this change the sole host-PCI bridge driver converted to
actually make use of PCI domain support is uninorth(4), the others
continue to use domain 0 only for now and need to be converted as
appropriate later on.
Note that this means that the format of the location strings as used
by pciconf(8) has been changed and that consumers of <sys/pciio.h>
potentially need to be recompiled.
Suggested by: jhb
Reviewed by: grehan, jhb, marcel
Approved by: re (kensmith), jhb (PCI maintainer hat)
not exsist, do not have ioctl return an error, but instead set -1
in the data returned to the user. This allows the HP bios flash
utilities to work without requiring changes to their code.
Reviewed by: jhb
Introduce d_version field in struct cdevsw, this must always be
initialized to D_VERSION.
Flip sense of D_NOGIANT flag to D_NEEDGIANT, this involves removing
four D_NOGIANT flags and adding 145 D_NEEDGIANT flags.
parameter in the read and write case dereferenced an unitialized
pointer and can't possibly ever have catched an actual invalid
argument.
This was apparently true for the read/write and getconf cases. The
latter does not even receive the paramter that is to be verified.
I'm surprised that this did not cause kernel panics, but it seems
that the uninitialized local variable happens to contain data that
may be used as a pointer to memory that satisfies the test condition.
Make the code work as intended by moving the test inside the switch
case where the pointer has been properly initialized.
Since the read and write case shared just about all code (except
for the single call to PCIB_READ_CONFIG resp. PCIB_WRITE_CONFIG) I
have merged both cases.
Noticed by: trhodes@FreeBSD.org (Tom Rhodes)
read permision only required for listing, read/write required for
read/write to registers
fix a possible memory leak
clean up error handling a bit
Reviewed by: silence
branches:
Initialize struct cdevsw using C99 sparse initializtion and remove
all initializations to default values.
This patch is automatically generated and has been tested by compiling
LINT with all the fields in struct cdevsw in reverse order on alpha,
sparc64 and i386.
Approved by: re(scottl)
Note ALL MODULES MUST BE RECOMPILED
make the kernel aware that there are smaller units of scheduling than the
process. (but only allow one thread per process at this time).
This is functionally equivalent to teh previousl -current except
that there is a thread associated with each process.
Sorry john! (your next MFC will be a doosie!)
Reviewed by: peter@freebsd.org, dillon@freebsd.org
X-MFC after: ha ha ha ha
- Break out the /dev/pci driver into a separate file.
- Kill the COMPAT_OLDPCI support.
- Make the EISA bridge attach a bit more like the old code; explicitly
check for the existence of eisa0/isa0 and only attach if they don't
already exist. Only make one bus_generic_attach() pass over the
bridge, once both busses are attached. Note that the stupid Intel
bridge's class is entirely unpredictable.
- Add prototypes and re-layout the core PCI modules in line with
current coding standards (not a major whitespace change, just moving
the module data to the top of the file).
- Remove redundant type-2 bridge support from the core PCI code; the
PCI-CardBus code does this itself internally. Remove the now
entirely redundant header-class-specific support, as well as the
secondary and subordinate bus number fields. These are bridge
attributes now.
- Add support for PCI Extended Capabilities.
- Add support for PCI Power Management. The interface currently
allows a driver to query and set the power state of a device.
- Add helper functions to allow drivers to enable/disable busmastering
and the decoding of I/O and memory ranges.
- Use PCI_SLOTMAX and PCI_FUNCMAX rather than magic numbers in some
places.
- Make the PCI-PCI bridge code a little more paranoid about valid
I/O and memory decodes.
- Add some more PCI register definitions for the command and status
registers. Correct another bogus definition for type-1 bridges.