out because the rc.conf(5) variable was not enabled. Display a
message that the command wasn't run and offer suggestions on
what the user can do.
Implement a quiet prefix, which will disable some diagnostics. The
fast prefix also implies quiet. During boot we use either fast or
quiet. For shutdown we already use 'faststop'. So, this informational
message should only appear during interactive use.
An additional benefit of having a quiet prefix is that we can start
putting some of our diagnostic messages behind this knob and start
"de-cluttering" the console during boot and shutdown.
so that when using named from the ports (or elsewhere) the proper rndc*
commands will be run.
2. Rework the stop routine using ideas from brooks and delphij.
Specifically I am duplicating a lot of code from rc.subr's stop routine
so that this one will behave more like the one in rc.subr, but use rndc
to kill the daemon (or regular kill if that fails). This also avoids
the problems related to using killall if rndc fails, which is bad if
you're running more than one named on the same box.
3. Take a concept from gshapiro and allow the rndc.key file to be
owned by root OR the named_uid user.
Although I used different solutions, this commit handles issues raised in:
PR: conf/73929
PR: conf/103976
PR: conf/109409
is then used as an argument to the amd program. This outpu may contain
newlines, but the script did not take care to strip those newlines before
apending it to rc_flags. Revision 1.72 of rc.subr(8) introduced changes that
exposed this problem (specifically putting the final eval'ed command in
quotes).[1]
Also, for correctness' sake, shell directives appended to the command-line
by the script should go into command_args, and not appended directly
to rc_flags.
Reported by: John E Hein <jhein@timing.com> [1]
Tested by: John E Hein <jhein@timing.com>
MFC after: 1 week
This commit includes the following core components:
* sample configuration file for sensorsd
* rc(8) script and glue code for sensorsd(8)
* sysctl(3) doc fixes for CTL_HW tree
* sysctl(3) documentation for hardware sensors
* sysctl(8) documentation for hardware sensors
* support for the sensor structure for sysctl(8)
* rc.conf(5) documentation for starting sensorsd(8)
* sensor_attach(9) et al documentation
* /sys/kern/kern_sensors.c
o sensor_attach(9) API for drivers to register ksensors
o sensor_task_register(9) API for the update task
o sysctl(3) glue code
o hw.sensors shadow tree for sysctl(8) internal magic
* <sys/sensors.h>
* HW_SENSORS definition for <sys/sysctl.h>
* sensors display for systat(1), including documentation
* sensorsd(8) and all applicable documentation
The userland part of the framework is entirely source-code
compatible with OpenBSD 4.1, 4.2 and -current as of today.
All sensor readings can be viewed with `sysctl hw.sensors`,
monitored in semi-realtime with `systat -sensors` and also
logged with `sensorsd`.
Submitted by: Constantine A. Murenin <cnst@FreeBSD.org>
Sponsored by: Google Summer of Code 2007 (GSoC2007/cnst-sensors)
Mentored by: syrinx
Tested by: many
OKed by: kensmith
Obtained from: OpenBSD (parts)
ppp_profile variable can now contain multiple profiles.
Overrides for ppp mode and nat can go into ppp_$profile_mode
and ppp_$profile_nat variables respectively. If those are
not specified, defaults from ppp_mode and ppp_nat are used.
Submitted by: Yuri Kurenkov < y dot kurenkov at init dot ru >
Reviewed by: mtm
MFC after: 1 week
local rc.d scripts in the overall boot order was added.
Proper rc.d scripts are run by rc.subr in a subshell, whereas scripts that
end in .sh are sourced into rc's shell. The latter has potential to create
serious boot problems, and there is no reason that the same functionality
cannot be added by the user in the form of a proper rc.d script (as
opposed to being added by the user in the form of /etc/rc.early).
This script will be removed prior to the 8.0 branch.
Approved by: re (kensmith)
otherwise the /dev/mdX.uzip won't be created immediately, which is
needed because we issue a mount right afterwards.
Approved by: re@ (bmah@)
MFC after: 2 days
so that when I applied the patch to my check-in tree the top half of my patch failed to
apply. Off course I saw what I *expected* to see (the bottom half succeeded) and
didn't notice that it had failed to apply cleanly.
Approved by: re (bmah)
in most cases, except one. The 'restart' case was not working as expected. Specifically,
it would stop both lockd and statd, but it would restart only statd (which appears first
in the script). This is because rc.subr(8) contains code to guard against infinite
recursion in the 'restart' casae.
To fix this use the traditional approach of controlling only one server from one script by
breaking out rc.d/nfslocking into its contituent parts: rc.d/lockd and rc.d/statd. Keep
rc.d/nfslocking around but don't include it in the boot rcorder(8)ing.
PR: conf/107316
Approved by: re (bmah)
MFC after: 2 weeks
wpa_supplicant and other programs started by 'netif' don't get erased
by a subsequent 'cleanvar'.
Approved by: re (bmah)
Reviewed by: dougb
MFC after: 1 week
/etc/rc.d/sendmail whether or not to run newaliases if the database
is missing or the aliases text file is newer than aliases.db.
In my opinion, the aliases file should never be automatically rebuilt.
The current text form could represent a work in progress. Therefore,
in FreeBSD 7.0, this new option will default to "NO". When this rc.d
change is MFC'ed, it will need to remain "YES" to maintain backward
compatibility.
PR: conf/86252
Approved by: re (kensmith)
MFC after: 3 days
/etc/rc.d/hostid now that we switched the origin of the UUID (variable
smbios.system.uuid as provided by the i386 BIOS code) to already provide
a standard conforming lower-case UUID text representation.
usage to an equivalent csh(1) usage as tr(1) stays in /usr/bin and
/etc/rc.d/hostid has just the root filesystem (and this way mainly the
tools in /bin) available.
I've chosen csh(1) here as the string manipulation tools available in
/bin is extremely limited and the (only) alternative ed(1) usage would
have been a lot more complicated or even might require a temporary file.
and ISO/IEC-9834-8:2005 is with LOWER-CASE hexadecimal characters only,
so translate the (usually upper-case and this way not conforming)
representation of the BIOS UUID when reading it. Also be more strict
about the valid characters in the textual representation by checking for
just the hexadecimal characters.
scripts in rc.d to stop rc(8) from booting into multi-user mode when
a critical or severe error condition is encountered.
o Modify scripts in etc/rc.d that already implemented this functionality
independently.
o Document it.
[1] - This subroutine was implemented in FreeBSD in rc.d/fsck. I moved it
to rc.subr(8). Our version differs slightly in that it takes an
optional argument to stop the boot even if "autoboot" is not set.
Obtained from: NetBSD
MFC after: 2 weeks
"forced". If some pre-condition is not met, it should fail as it normally
does and rc.subr(8) will make the appropriate decision. Incidentally, the
previous behaviour had a bug where the "force" flag was respected only
when checking rc.conf(5) knobs. The flag was ignored when verifying the
rpcbind(8) dependency.
MFC after: 2 weeks
dependency was introduced because this script had rc.d/localpkg (which is
*after* rc.d/NETWORKING) in its REQUIRE line.
From an examination of its contents it seems that only the availability of
a local filesystem is necessary for this script to function properly.
'zfs mount -a' from the main system - this is by design, as mountpoint
may be set to dangerous value. This all means, that such file system
has to be mounted from within a jail. To make it easier, reorganize
rc.d/zfs script so it can be used from within a jail.
NFS-share anything. This way we can safely start mountd with
/etc/zfs/exports and mountd won't complain.
Pointed out by: ceri
- Move 'zfs volinit' before 'zfs mount -a' and 'zfs volfini' after
'zfs unmount -a'.
software-generated UUID. Store the result in /etc/hostid and use it in
the future. Perform simple UUID format check, as there is a lot of
hardware with broken UUIDs. The check should be improved to also eliminate
fake UUIDs like 00000000-0000-0000-0000-000000000000.
Requested by: many
which can be used to turn off multicast pfsync support, and enable
the transmission of directed PFSYNC (IP protocol: 240) packets to
a specific "sync peer" host.
PR: conf/111225
Submitted by: Bas van Beek <bas@tobin.nl>
Approved by: mtm, mlaier
MFC after: 2 weeks
UUID and stores it in /etc/hostid ($hostid_file) as well as sets kern.hostuuid
and kern.hostid sysctls on every boot.
Hostid can be reset using '/etc/rc.d/hostid reset' command.
Hostid generation and setting can be turned off by setting variable
hostid_enable to "NO" in /etc/rc.conf.
Reviewed by: mlaier, rink, brooks, rwatson
and takes over mountcritlocal's role as the early / late divider. This
makes it far easier to add rc scripts which need to run early, such as a
startup script for zfs, which is right around the corner.
This change should be a no-op; I have verified that the only change in
rcorder's output is the insertion of FILESYSTEMS immediately after
mountcritlocal.
MFC after: 3 weeks
If the firewall script is sourced directly from the script, then any
exit statements in it will also terminate the rc.d script prematurely.
PR: conf/78762
MFC-After: 2 weeks
The code looks for all the loaded screensaver modules, tries to
kldunload them, and only loads the new one if kldstat's output shows
that there aren't any left. However, the regexp looking for modules
to unload was still searching according to the the old naming scheme,
splash_<name>.ko, instead of <name>_saver.ko.
MFC after: 3 days
the background fsck indefinitely. This allows the administrator to run
it at a convenient time. To support running it from cron, the
forcestart argument now causes the fsck to start with no delay and all
output to be suppressed.
Include /var/db/entropy-file in the reseeding if present. It is used for
last-ditch efforts to save entropy and thus should also be used to seed
the RNG when starting. Print a warning instead of an error if writing the
file fails -- err() exits, preventing the umask from being restored.
Also, since there's not much that can be done about it, notifying the user
is all that's needed.
MFC after: 2 weeks
Note: This also deprecates "NO" as a way to specify an empty list of
interfaces for gif_interfaces.
PR: conf/104884
Submitted by: nork
Harassed by: brd
Discussed with: brooks, dougb
modern dual-core systems as well.
- Parse the _CST packages for each cpu and track all the states individually,
on a per-cpu basis.
- Revert to generic FADT/P_BLK based Cx control if the _CST package
is not present on all cpus. In that case, the new driver will
still support per-cpu Cx state handling. The driver will determine the
highest Cx level that can be supported by all the cpus and configure the
available Cx state based on that.
- Fixed the case where multiple cpus in the system share the same
registers for Cx state handling. To do that, added a new flag
parameter to the acpi_PkgGas and acpi_bus_alloc_gas functions that
enable the caller to add the RF_SHAREABLE flag. This flag could also be
useful to other callers (acpi_throttle?) in the tree but this change is
not yet made.
- For Core Duo cpus, both cores seems to be taken out of C3 state when
any one of the cores need to transition out. This broke the short sleep
detection logic. It is disabled now if there is more than one cpu in
the system for now as it fixed it in my case. This quirk may need to
be re-enabled later differently.
- Added support to control cx_lowest on a per-cpu basis. There is still
a generic cx_lowest to enable changing cx_lowest for all cpus with a single
sysctl and for ease of use. Sample output for the new sysctl:
dev.cpu.0.cx_supported: C1/1 C2/1 C3/57
dev.cpu.0.cx_lowest: C3
dev.cpu.0.cx_usage: 0.00% 43.16% 56.83%
dev.cpu.1.cx_supported: C1/1 C2/1 C3/57
dev.cpu.1.cx_lowest: C3
dev.cpu.1.cx_usage: 0.00% 45.65% 54.34%
hw.acpi.cpu.cx_lowest: C3
This work was done by Stephane E. Potvin with some simple reworking by
myself. Thank you.
Submitted by: Stephane E. Potvin <sepotvin / videotron.ca>
MFC after: 2 weeks
in a previous commit to avoid namespace collisions, unfortunately I missed two
of them. This leads to the ip alias being incorrectly removed in some cases
when using the stop command.
Reported by: Philipp Wuensche <cryx-freebsd@h3q.com>
scripts, except for mdconfig* and jail. Such symbols are reserved
for the rc.subr internals. Most scripts can be fixed by just
declaring _foo symbols as local: few scripts actually need them to
be global.
Discussed with: dougb in freebsd-rc
A kernel with INET6 always has ::1 on lo0, so in the case of
ipv6_enable="NO" the lo0 can have ::1 with no link-local address.
This is a violation of the IPv6 specification. As a workaround for
this situation, fe80::1 is added in rc.d/auto_linklocal when lo0 has
no link-local address. This should not be harmful for IPv4-only users.
+ Use rc.subr(8) features properly.
+ Do the whole job of obliterating /tmp contents in find(1).
+ Leave lost+found and quota.{user,group} in /tmp only if root-owned.
+ Make the overall structure clearer by first removing the X dirs
(perhaps along with the rest of /tmp) and then re-creating them.
+ Use "find -exec rm -rf {} +" for efficiency: each rm instance gets
a chance to kill as much files in /tmp as ARG_MAX permits.
PR: bin/104044
Submitted by: Andrey Simonenko <see PR for email>
Hacked by: yar
MFC after: 1 month
chance to actually terminate the audit service and exit. Otherwise, on
an rc.d/auditd restart, the new audit daemon instance may try to start
auditing while the previous session is still running. Likewise, this
ensures a chance for auditd to terminate the audit trail at system
shutdown.
Perhaps more ideally, the script would wait synchronously for auditd to
exit rather than for an arbitrary but short period of time.
MFC after: 3 days
Obtained from: TrustedBSD Project
certain conditions. I haven't been able to find a better solution yet:
- Set a two read-only variables (${prefix} and ${etcdir}). This is
especially useful when using /etc/rc.d scripts with third-party
software installed from ports.
- Fix rc.d/sshd to work with openssh from ports using ${etcdir}
instead of hardcoded /etc.
- Reflect prefix/etcdir changes in rc.subr.8.
src/etc/rc.d/sshd: rev 1.9 -> 1.10
src/etc/rc.subr: rev 1.51 -> 1.52
src/share/man/man8/rc.subr.8: rev 1.11 -> 1.12
Approved by: cperciva (mentor)
despite the interface link status.
Add dhclient_flags_iface and background_dhclient_iface rc.conf options.
(where iface is a specific interface). These can be used to give
interface specific flags to dhclient.
Reviewed by: brooks@
and replace it with a new ntpdate_config variable.
- Document it in defaults/rc.conf and rc.conf.5.
- Document ntpdate_hosts in defaults/rc.conf.
Requested by: Chris Timmons <cwt@networks.cwu.edu>
Approved by: cperciva (mentor, implicit)
MFC after: 1 week
not be mounted unless the -l flag was specified.
Add an rc script, mountlate, which basically runs 'mount -a -l'. It runs
after DAEMON but before LOGIN.
This is useful for things like loopback mounts, because mountcritremote
runs before mountd / nfsd (since /usr might be a remote file system), so
an attempt to mount a loopback network file system in mountcritremote will
fail.
Also add a progress message to mountcritlocal, for the sake of symmetry
with similar messages in mountcritremote and mountlate.
Reviewed by: freebsd-rc
MFC after: 3 weeks
expect to see quite a few files appearing in libdata/ldconfig directories.
This change avoids the screen to be filled with the names of those ldconfig
files and replace them by the actual non-default directories they contain.
Most of them will be ${PREFIX}/lib so, 'sort -u' will help reducing the
output.
Approved by: cperciva (implicit)
MFC after: 1 week
automaticly add it to an Ethernet bridge. This is intended for applications
such as qemu, vmware, openvpn, ... which open tap interfaces and need them
bridged with the hosts network adapter, the user can set up a glob for
interfaces to be automatically added (eg tap*).
notification so all interfaces including pseudo are reported. When netif
creates the clones at startup devctl_disable has not been turned off yet so the
interfaces will not be initialised twice, enforce this by adding an explicit
order between rc.d/netif and rc.d/devd.
This change allows actions to taken in userland when an interface is cloned
and the pseudo interface will be automatically configured if a ifconfig_<int>=""
line exists in rc.conf.
Reviewed by: brooks
No objections on: net
1,2 and so on.
It specifies the command to be run as Nth after jail startup.
sh(1)-fu by: Dario Freni
PR: conf/97697
MFC after: 2 weeks
Reviewed by: ru@ (man page)
scripts. These scripts handle vnode backed md(4) devices.
Old ramdisk{,-own} scripts will stay a bit in CVS to allow some time for
migration since variable names have changed (ramdisk_* -> mdconfig_*).
Two new variables have been introduced to be able to populate the md(4)
device once it has been mounted (mdconfig_*_files and mdconfig_*_cmd).
Use should be as easy as:
mdconfig_md0="-t malloc -s 10m"
mdconfig_md1="-t vnode -f /var/foo.img"
See rc.conf(5) for more information and description of the additional
variables.
Approved by: cperciva
issue where some global jail_* variables were overriden in the script. [1]
- Change "jid" to "jname" in rc.conf(5), since it's more a jail name than a
jail id. [1]
- Update examples and comments in defaults/rc.conf to advertise new
variables and the fact that some of the jail-specific variables may be made
jail-global. [2]
Reported by: pjd [1], clsung [2]
Approved by: cperciva
X-MFC after: i got sufficient testing from people using rc.d/jail
boot. Autogeneration of nsswitch.conf doesn't makes sense in 7.0
since it's not permitted to upgrade from a pre-nss release without
passing through an intermediate release.
Suggested by: brooks
for some early starting services from the ports collection
to have their shared objects available before start.
Reviewed by: freebsd-rc (dougb, brooks)
MFC After: 3 days
from ports. The effect is that ldconfig is now started right after
mountcritremote. Everything else is left unchanged.
PR: conf/68916
Submitted by: JD Bronson <jd@aurora.org>
Approved by: cperciva (mentor)
MFC after: 1 week
- Add the according amd_program default value in defaults.
PR: conf/82738
Submitted by: TAOKA Fumiyoshi <fmysh@iijmio-mail.jp>
Approved by: cperciva (mentor)
MFC after: 3 days
especially useful when using /etc/rc.d scripts with third-party
software installed from ports.
- Fix rc.d/sshd to work with openssh from ports using ${etcdir}
instead of hardcoded /etc.
Reviewed by: brooks
Approved by: cperciva (mentor)
MFC after: 1 week
set:
* jail_mount_enable
* jail_devfs_ruleset
* jail_devfs_enable
* jail_fdescfs_enable
* jail_procfs_enable
* jail_fstab
* jail_flags
- Add a jail_interface / jail_<jid>_interface option. An ip alias will be
created (jail_<jid>_ip) on jail_interface or jail_<jid>_interface if set.
This is not a mandatory option.
- Document all missing jail_* options in rc.conf(5).
Approved by: cperciva (mentor)
MFC after: 2 weeks
daemon in the base system and all the IKE daemons in the Ports
Collection has their own rc.d script.
OK'ed by: dougb
Discussed on: freebsd-rc
MFC after: 1 month
Approved by: cperciva (mentor)
you booted from, unless /boot/kernel already exists and is not a symlink.
This should only affect people like me who juggle multiple kernels and
have KODIR = /boot/${KERN_IDENT} in /etc/make.conf to keep them apart.
into one function syscons_configure_keyboard(). Call new function from
both syscons_start() and sysconst_setkeyboard(). The reason for this
is because syscons_start() will (re)configure both keyboard and screen
settings. Apparently, some graphics cards have problems with running
vidcontrol(1) while X11 is running.
Remove "/etc/rc.d/syscons restart" from /etc/devd.conf. It is no longer
required. Using "/etc/rc.d/syscons setkeyboard" is enough. This also
should fix annoying "syscons not running?" message.
Tested by: Ulrich Spoerlein < q at galgenberg dot net >
MFC after: 3 days
keyboard device name (i.e. /dev/kbd0). This method will do nothing is
kbdmux(4) is the current active keyboard, otherwise it will switch
active keyboard as requested.
Modify ukbd(4) entries in the /etc/devd.conf to use /etc/rc.d/syscons
and new 'setkeyboard' method.
No comments from: freebsd-current@
MFC after: 1 day
the ongoing re-alignment of ordering that is necessary as a result of
including local scripts in the base rcorder. [1]
Accomplish this by removing the BEFORE's, and using REQUIRE instead.
This makes the dependencies more obvious, and less susceptible to turning
circular and/or nonsensical when seemingly innocent changes are made
in one place and not another.
Requested by: delphij [1]
and not under machdep as the behaviour is controlled by the process.
When PSR.ac is set the process expects to receive a SIGBUS. Otherwise
the processor or the kernel will emulate the misaligned memory access.
MFC after: 3 days
1. Remove a now-spurious NetBSD CVS Id, as we are no longer synching work
2. Remove a now-spurious BEFORE, since ntpdate now REQUIRE's named
3. Replace the call to set rcvar with what that function would output,
and generally reduce indirection ($name -> named) since it's highly
unlikely the name of the named process or service will change any time soon.
4. Resort the order the variables at the top of the file to a more
traditional format, and remove a spurious required_dirs from the top, as it
works better after load_rc_config.
5. We do not want the default reload method with named, so define a simple
but appropriate substitute using rndc. If I were writing this script for
the first time I would not include this at all, since it's preferable to
control a running daemon with rndc to start with, but given that this is
already here, let's do it right. I hope that future generations will
however resist the tempation to add reconfig to extra_commands.
6. By the same token, we want to use rndc to shut down named, but given
that by defining a stop function we lose the "find the process by its
pid file in an emergency" goodness of rc.subr, try to do something useful
in the event that rndc is not available, and keep the user informed.
7. Replace some "test -f" with "test -r" to handle the unlikely event
that the relevant file exists, but is unreadable.
8. Twiddle whitespace in a few areas, remove a spurious blank line,
a bogus double space, and try to do better indenting.
9. Improve generation of the rndc.key file significantly
a. If for some reason a user has an rndc.conf file, assume that they
did that on purpose, and hence know what they are doing, so leave them alone.
b. Introduce a named_uid configuration variable so that the user which owns
the rndc.key file and the user named runs as always match, and is more
easily configurable. This should dramatically reduce problems with rndc.
c. Also test that the rndc.key file size is greater than zero, rather than
simply that the file exists. I have seen at least one user report this exact
problem, and although neither of us is sure where the empty file came from,
the fix is simple, so include it.
d. Rather than try to create an rndc.key file in both /etc/namedb and the
chroot'ed /etc/namedb, assume that they are be the same (which they should
be), and only create the file in the chroot'ed version of the directory.
This partially addresses the problem described in conf/73929, but I have
not yet finished thinking about the PREFIX issue that PR also raises.
As a result of introducing the named_uid knob, the default named_flags
are now empty.
Update defaults/rc.conf and rc.conf(5) to reflect these changes.
Allow user to decide if SAD and SPD entries should be flushed on 'reload'.
With this change flush/spdflush is not done automatically (it could still
be done from ipsec.conf).
RELENG_6 this will be a noop, however as we introduce local
startup scripts to the base rcorder, we'll see more cases
where the previous status quo will need to be made explicit
to avoid having it disrupted when random local scripts are
added to the mix.
were now sticky. This script was deleting /boot/nextkernel on boot, but
there is no code in the tree that creates that file since revision 1.15
of src/sbin/reboot/reboot.c.
nextboot(8) creates /boot/nextboot.conf, so remove that instead.
Approved by: jhb (proxy mentor)
MFC after: 1 week
ldconfig. Build the cache in a temporary directory and only install it
if it's actually different that the installed one.
Also, use "cat tmp > real" to install the temporary file in the real
location to allow the real location to be a symlink to a writable
directory such as /var/run (where the file actually belongs).
MFC After: 5 days
the names of directories to include in the base ldconfig script.
This will eliminate the need for each port to install its own
boot script which does nothing but ldocnfig a given directory.
This code was developed by flz (ports committer), discussed on
freebsd-rc@, and modified slightly by me.
Submitted by: flz
Reviewed by: brooks
the line continuation backslash doesn't cause "warn" to print "return".
2. Group "warn" and "return" together as the "return 1" should be
performed only if the "kldload nfsclient" also failed (and not
already if the "vfs.nfs" sysctl(8) check failed).
MFC after: 3 days
on devfs is useful so that a hardware time device can start with its
necessary device nodes already in place. While this ordering happens
as a side effect currently in HEAD, and the PRs were generally fixed
via upgrades, etc; it's better to make it explicit.
While I'm here, ntpd should REQUIRE ntpdate, rather than ntpdate
using BEFORE: ntpd.
and including both in this file had nasty side effects on the
ordering of syslogd, as well as producing an error when running
rcorder. Remove the more bogus of the two options, which restores
proper ordering and removes the error.
There is an open question as to whether scripts with the nostart
KEYWORD should even have REQUIRE/BEFORE lines, and indeed, whether
they should be in /etc/rc.d at all, but that's for another time.
by default, so add a new knob that is on by default, and check that
knob in start_precmd so that it can run even if cleaning /tmp is
not enabled. This has the advantage of not violating POLA, while
still allowing the user to disable this behavior if they wish (for
example on a server that will never run X).
to light by the PR. Specifically, convert these three scripts
into good rc.d citizens, making sure that their functionality
is preserved, but the rc.d framework rules are not broken.
Add support for cleanvar as a regular rc.d script in the
default rc.conf, and document this in the man page.
Add a descriptive comment to rc.conf that regarding the
three emulation/compatibility services provided by abi
so users will not be confused by these services not having
their own startup scripts.
PR: conf/84574
Submitted by: Alexander Botero-Lowry
as part of rc. Doing this, and the sourcing of rc.subr after we have
determined if we are booting diskless (and correspondingly run
rc.initdiskless if necessary) are safe, and actually allow fewer files
to be needed on the diskless box. This also allows variables from
the configuration to be available to rc itself, such as ...
Add a variable to rc.conf, early_late_divider, which designates the
script which separates the early and late stages of the boot process.
Default this to mountcritlocal, and add text to etc/defaults/rc.conf,
rc.conf(5) and diskless(8) which describes how and why one might want
to change this.
Reviewed by: brooks