terminology).
Adds command "mfiutil syspd <drive#>" to change a drive to SYSPD. Drive
will then be scanned/reported immediately as /dev/mfisyspdX by the host.
"mfiutil good <drive#>" clears SYSPD mode, remove /dev/mfisyspdX and
sets disk into UNCONFIGURED mode.
Tested on Dell H310 SAS/SATA RAID controller.
MFC after: 2 weeks
Sponsored by: Yahoo! Inc.
relearning. Specifically, add subcommands to mfiutil(8) which allow the
user to set the BBU and autolearn modes when the firmware supports it,
and add a subcommand which kicks off a battery relearn.
Reviewed by: sbruno, rstone
Tested by: sbruno
Approved by: rstone (co-mentor)
MFC after: 2 weeks
Sponsored by: Sandvine Incorporated
and use a loop so that multiple cache commands can be strung together on
the command line into a single update to the volume's properties.
Reviewed by: bz
Approved by: re (kib)
MFC after: 1 week
commands for a given adapter. Specifically, it shows the status of any
drive or volume activities currently in progress similar to the
'drive process' and 'volume progress' commands.
Reviewed by: emaste
MFC after: 1 week
back-up is missing or dead. The current state of this field is reported
in 'mfiutil cache <volume>' and can be adjusted via
'mfiutil cache <volume> bad-bbu-write-cache <enable|disable>'. This
setting should generally be disabled to avoid data loss.
MFC after: 1 week