is when the matched string spans the end of the inbuff. This fix allocates
twice the IBSIZE so that it can keep the last and the current text to search
in the inbuff so that the match won't fail if it gets truncated by the read.
It also warns if the search string is to long and truncates it.
Submitted by: Dough Ambrisco <ambrisco@ambrisco.roble.com>
*not* our controlling terminal (SIGHUP can coming in other case)
2) Add HUPCL for non-dedicated lines to be shure that modem
properly resetted.
3) Correct usage string.
2) Improve on-line help subsystem
3) Make 'term' mode works even carrier dropped (old code
close line forever here)
4) Make 'term' mode 8bit clean.
5) Improve manual page
6) #ifdef DEBUG diagnostic about missing optional files.
7) Don't put interactive dialing info to logfile
ppp based on these patches for about 3 weeks with no downtime.
The original submitters comments:
Two features iijppp has over kernel ppp that I like are predictor1
compression and demand dialing. Here are a few bug fixes.
I expanded the priority queueing scheme and discovered it was broken
due to the assignment at ip.c line 300. All packets were being
queued at the same priority.
Fixing priority queueing broke predictor1 compression. Packets
were compressed before being queued and predictor1 worked as long
as the packets were popped off the queue in the same order they
were pushed onto the queue.
There were a few byte order problems in IP header tests also.
There is a recursion problem in SendLqrReport(). LcpClose() is
called when "Too many echo packets are lost" which winds up in
SendLqrReport() again. I believe the original intention was to
just stop the LQR timer with the call to StopLqr() but the side
effects hurt.
Submitted by: John Capo <jc@irbs.com>
A settable redial timer helps to avoid the problem where both ends
of a link want to dial at the same time and the line winds up busy
for both ends. The process id is logged in /var/run/PPP.system where
system is the name of the called system. When both ends of a link
are running in demand dial mode, you need an easy way to get the pid
of the ppp on the called end so it can be killed and re-started with
-direct or pppd started to handle the incoming ppp session.
2. Add secret description for "set timeout" to man.
Reviewed by: Atsushi Murai <amurai@spec.co.jp>
Submitted by: John Capo <jc@irbs.com>
dropped - devet@adv.IAEhv.nl (Arjan de Vet)
2. Will not read data from telnet connection - John Capo <jc@irbs.com>
3. Using LQM option could be drop the link due to LcpLayerDown() doesn't
stop LQR timer. - Brian <brian@awfulhak.demon.co.uk>
4. Allow to describe a syntax of filters that is not only port number
but also by name in /etc/service. - Rich Murphey <rich@lamprey.utmb.edu>
Reviewed by: Atsushi Murai <amurai@spec.co.jp>
Submitted by: devet@adv.IAEhv.nl, jc@irbs.com, brian@awfulhak.demon.co.uk,
rich@lamprey.utmb.edu
one) as a valid answer to an echo request. This makes the log less
noisy when connecting to Trumpet Winsock or FreeBSD 2.0.5's pppd. :)
Submitted by: melvin@zytek.com (Stephen Melvin)
2. Optimize ModemQlen.
3. Sending ProtoReject for Unknow protocol (i.e. IPX)
4. Avoid select looping by reading tun under the high system load.
5. Adding Local version String for maintenance.
6. Just more speak rather silent ignore if you type invalid key words.
>Category: bin
>Synopsis: SPAP request REJexted in stead of NAKed
>Confidential: no
>Severity: non-critical
>Priority: low
>Responsible: freebsd-bugs (FreeBSD bugs mailing list)
>State: open
>Class: sw-bug
>Submitter-Id: current-users
>Arrival-Date: Wed Jul 5 01:40:01 1995
>Originator: Dick van den Burg
>Organization:
>Release: FreeBSD 2.0.5-RELEASE i386
>Environment:
>Description:
When trying to connect with ppp to a Shiva Lanrover (version 3.2) the
authentication fails because the SPAP (Shiva Secure PAP) configuration
request the is sent by Shive is REJected by ppp in stead of NAKed.
Reviewed by: amurai@spec.c.jp and friends
Submitted by: burg@is.ge.com
The first problem I found was that descriptor 0 was being closed.
This happens because the modem variable is set to 0 to indicate
that it is not valid but there are not enough tests for the modem
variable being 0. You can see where I have done this in the patch.
Code in OpenModem() dups the modem descriptor if it is < 3. Once
this happened the modem was always open and an incomming call would
have getty and ppp reading the modem.
Descriptor 1 is closed when the quit command was executed from a
telnet connection. The next modem open returns descriptor 1
and this gets duped leaving the modem always open again.
The modem was not being closed when the connection dropped or was
closed from the other end. The UUCP lock was also not removed if
the modem could not be opened.
Reviewed by: Atsushi Murai <amurai@spec.co.jp>
Submitted by: John Capo <jc@irbs.com>
2.Implment Redail function as working correctly.
3.Clean up a code as I notice.
4.Now, RTT getting close to 50ms with ISDN/TA 38400bps !!
Reviewed by: amurai@spec.co.jp
Submitted by: amurai@spec.co.jp