the no-longer existant sb_cc sockbuf member.
- Use sbavail() instead of sbused() in t4_soreceive_ddp() to match the
usage in soreceive_stream() on which it is based.
Discussed with: glebius (2)
sending not ready data:
o Add new flag to pru_send() flags - PRUS_NOTREADY.
o Add new protocol method pru_ready().
Sponsored by: Nginx, Inc.
Sponsored by: Netflix
o Introduce a notion of "not ready" mbufs in socket buffers. These
mbufs are now being populated by some I/O in background and are
referenced outside. This forces following implications:
- An mbuf which is "not ready" can't be taken out of the buffer.
- An mbuf that is behind a "not ready" in the queue neither.
- If sockbet buffer is flushed, then "not ready" mbufs shouln't be
freed.
o In struct sockbuf the sb_cc field is split into sb_ccc and sb_acc.
The sb_ccc stands for ""claimed character count", or "committed
character count". And the sb_acc is "available character count".
Consumers of socket buffer API shouldn't already access them directly,
but use sbused() and sbavail() respectively.
o Not ready mbufs are marked with M_NOTREADY, and ready but blocked ones
with M_BLOCKED.
o New field sb_fnrdy points to the first not ready mbuf, to avoid linear
search.
o New function sbready() is provided to activate certain amount of mbufs
in a socket buffer.
A special note on SCTP:
SCTP has its own sockbufs. Unfortunately, FreeBSD stack doesn't yet
allow protocol specific sockbufs. Thus, SCTP does some hacks to make
itself compatible with FreeBSD: it manages sockbufs on its own, but keeps
sb_cc updated to inform the stack of amount of data in them. The new
notion of "not ready" data isn't supported by SCTP. Instead, only a
mechanical substitute is done: s/sb_cc/sb_ccc/.
A proper solution would be to take away struct sockbuf from struct
socket and allow protocols to implement their own socket buffers, like
SCTP already does. This was discussed with rrs@.
Sponsored by: Netflix
Sponsored by: Nginx, Inc.
sb_cc member of struct sockbuf to a couple of inline functions:
sbavail() and sbused()
Right now they are equal, but once notion of "not ready socket buffer data",
will be checked in, they are going to be different.
Sponsored by: Netflix
Sponsored by: Nginx, Inc.
initial MPA exchange must be tracked this way so that t4_tom's state for
the tid is all clean at the time the tid transitions to RDMA mode. Once
it does, t4_tom is out of the way and iw_cxgbe uses the qp endpoints
directly.
Sponsored by: Chelsio Communications
cannot be sent to the chip because a prerequisite L2 resolution
failed.
Submitted by: Hariprasad at chelsio dot com (original version)
MFC after: 2 weeks.
(I'm committing this on behalf of my colleagues in the Storage team
at Chelsio).
Submitted by: Sreenivasa Honnur <shonnur at chelsio dot com>
Sponsored by: Chelsio Communications.
the queue where to enqueue pages that are going to be unwired.
- Add stronger checks to the enqueue/dequeue for the pagequeues when
adding and removing pages to them.
Of course, for unmanaged pages the queue parameter of vm_page_unwire() will
be ignored, just as the active parameter today.
This makes adding new pagequeues quicker.
This change effectively modifies the KPI. __FreeBSD_version will be,
however, bumped just when the full cache of free pages will be
evicted.
Sponsored by: EMC / Isilon storage division
Reviewed by: alc
Tested by: pho
in6addr_any and is not in the CLIP table either. This fixes a reported
TOE+IPv6 NULL-dereference panic in do_pass_open_rpl().
While here, stop creating hardware servers for any loopback address.
It's just a waste of server tids.
MFC after: 1 week
them up as part of firmware initialization (which the driver gets to do
only if it's the master driver).
Read the range of tids available for the ETHOFLD functionality if it's
enabled.
New is_ftid() and is_etid() functions to test whether a tid falls within
the range of filter tids or ETHOFLD tids respectively.
MFC after: 2 weeks
set to 15 to indicate that the peer did not send a window scale option
with its SYN. Do not send a window scale option in the SYN|ACK reply
in that case.
- tom_uninit had to be reworked not to hold the adapter lock (a mutex)
around t4_deactivate_uld, which acquires the uld_list_lock.
- the ifc_match for the interface cloner that creates the tracer ifnet
had to be reworked as the kernel calls ifc_match with the global
if_cloners_mtx held.
when the interface is up.
- Add a tunable to control the TOE's rx coalesce feature (enabled by
default as it always has been). Consider the interface MTU or the
coalesce size when deciding which cluster zone to use to fill the
offload rx queue's free list. The tunable is:
dev.{t4nex,t5nex}.<N>.toe.rx_coalesce
MFC after: 1 day
includes support for the NIC and TOE features of the 40G, 10G, and
1G/100M cards based on the T5.
The ASIC is mostly backward compatible with the Terminator 4 so cxgbe(4)
has been updated instead of writing a brand new driver. T5 cards will
show up as cxl (short for cxlgb) ports attached to the t5nex bus driver.
Sponsored by: Chelsio
cannot be freed while do_pass_accept_req is running. This closes a race
where do_pass_establish on another CPU (the driver chose a different
queue for the new tid) expands the synq entry into a full PCB and then
releases the only hold on it, all while do_pass_accept_req is still
running.
MFC after: 3 days
This is the Compressed Local IPv6 table on the chip. To save space, the
chip uses an index into this table instead of a full IPv6 address in
some of its hardware data structures.
For now the driver fills this table with all the local IPv6 addresses
that it sees at the time the table is initialized. I'll improve this
later so that the table is updated whenever new IPv6 addresses are
configured or existing ones deleted.
MFC after: 1 week
- Teach find_best_mtu_idx() to deal with IPv6 endpoints.
- Install correct protosw in offloaded TCP/IPv6 sockets when DDP is
enabled.
- Move set_tcp_ddp_ulp_mode to t4_tom.c so that t4_tom.h can be included
without having to drag in t4_msg.h too. This was bothering the iWARP
driver for some reason.
MFC after: 1 week
- Add full support for IPv6 addresses.
- Read the size of the L2 table during attach. Do not assume that PCIe
physical function 4 of the card has all of the table to itself.
- Use FNV instead of Jenkins to hash L3 addresses and drop the private
copy of jhash.h from the driver.
MFC after: 1 week
on the fast data path) and use them instead of frobbing the adapter lock
and busy flag directly.
Other changes made while reworking all slow operations:
- Wait for the reply to a filter request (add/delete). This guarantees
that the operation is complete by the time the ioctl returns.
- Tidy up the tid_info structure.
- Do not allow the tx queue size to be set to something that's not a
power of 2.
MFC after: 1 week