088c26aee8
Misaligned floating point loads and stores are already handled for AIM, but use the DSISR to obtain the necessary data. Book-E does not have the DSISR, so these fixups are not performed, leading to a SIGBUS on misaligned FP loads or stores. Obtain the necessary data on the Book-E side, similar to how is done for SPE. MFC after: 1 week |
||
---|---|---|
.. | ||