freebsd-skq/sys/net/if_debug.c
pfg 78a6b08618 sys: general adoption of SPDX licensing ID tags.
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.

The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.

No functional change intended.
2017-11-27 15:23:17 +00:00

139 lines
4.0 KiB
C

/*-
* SPDX-License-Identifier: BSD-2-Clause-FreeBSD
*
* Copyright (c) 2010 Bjoern A. Zeeb <bz@FreeBSD.org>
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*/
#include <sys/cdefs.h>
__FBSDID("$FreeBSD$");
#include "opt_ddb.h"
#include <sys/param.h>
#include <sys/socket.h>
#include <sys/types.h>
#ifdef DDB
#include <ddb/ddb.h>
#endif
#include <net/if.h>
#include <net/if_types.h>
#include <net/if_var.h>
#include <net/vnet.h>
#ifdef DDB
struct ifindex_entry {
struct ifnet *ife_ifnet;
};
VNET_DECLARE(struct ifindex_entry *, ifindex_table);
#define V_ifindex_table VNET(ifindex_table)
static void
if_show_ifnet(struct ifnet *ifp)
{
if (ifp == NULL)
return;
db_printf("%s:\n", ifp->if_xname);
#define IF_DB_PRINTF(f, e) db_printf(" %s = " f "\n", #e, ifp->e);
IF_DB_PRINTF("%s", if_dname);
IF_DB_PRINTF("%d", if_dunit);
IF_DB_PRINTF("%s", if_description);
IF_DB_PRINTF("%u", if_index);
IF_DB_PRINTF("%u", if_refcount);
IF_DB_PRINTF("%d", if_index_reserved);
IF_DB_PRINTF("%p", if_softc);
IF_DB_PRINTF("%p", if_l2com);
IF_DB_PRINTF("%p", if_llsoftc);
IF_DB_PRINTF("%d", if_amcount);
IF_DB_PRINTF("%p", if_addr);
IF_DB_PRINTF("%p", if_broadcastaddr);
IF_DB_PRINTF("%p", if_afdata);
IF_DB_PRINTF("%d", if_afdata_initialized);
IF_DB_PRINTF("%u", if_fib);
IF_DB_PRINTF("%p", if_vnet);
IF_DB_PRINTF("%p", if_home_vnet);
IF_DB_PRINTF("%p", if_vlantrunk);
IF_DB_PRINTF("%p", if_bpf);
IF_DB_PRINTF("%u", if_pcount);
IF_DB_PRINTF("%p", if_bridge);
IF_DB_PRINTF("%p", if_lagg);
IF_DB_PRINTF("%p", if_pf_kif);
IF_DB_PRINTF("%p", if_carp);
IF_DB_PRINTF("%p", if_label);
IF_DB_PRINTF("%p", if_netmap);
IF_DB_PRINTF("0x%08x", if_flags);
IF_DB_PRINTF("0x%08x", if_drv_flags);
IF_DB_PRINTF("0x%08x", if_capabilities);
IF_DB_PRINTF("0x%08x", if_capenable);
IF_DB_PRINTF("%p", if_snd.ifq_head);
IF_DB_PRINTF("%p", if_snd.ifq_tail);
IF_DB_PRINTF("%d", if_snd.ifq_len);
IF_DB_PRINTF("%d", if_snd.ifq_maxlen);
IF_DB_PRINTF("%p", if_snd.ifq_drv_head);
IF_DB_PRINTF("%p", if_snd.ifq_drv_tail);
IF_DB_PRINTF("%d", if_snd.ifq_drv_len);
IF_DB_PRINTF("%d", if_snd.ifq_drv_maxlen);
IF_DB_PRINTF("%d", if_snd.altq_type);
IF_DB_PRINTF("%x", if_snd.altq_flags);
#undef IF_DB_PRINTF
}
DB_SHOW_COMMAND(ifnet, db_show_ifnet)
{
if (!have_addr) {
db_printf("usage: show ifnet <struct ifnet *>\n");
return;
}
if_show_ifnet((struct ifnet *)addr);
}
DB_SHOW_ALL_COMMAND(ifnets, db_show_all_ifnets)
{
VNET_ITERATOR_DECL(vnet_iter);
struct ifnet *ifp;
u_short idx;
VNET_FOREACH(vnet_iter) {
CURVNET_SET_QUIET(vnet_iter);
#ifdef VIMAGE
db_printf("vnet=%p\n", curvnet);
#endif
for (idx = 1; idx <= V_if_index; idx++) {
ifp = V_ifindex_table[idx].ife_ifnet;
if (ifp == NULL)
continue;
db_printf( "%20s ifp=%p\n", ifp->if_xname, ifp);
if (db_pager_quit)
break;
}
CURVNET_RESTORE();
}
}
#endif