freebsd-skq/sys/geom/vinum/geom_vinum_rm.c
pfg a82e3a8b24 sys/geom: adoption of SPDX licensing ID tags.
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.

The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
2017-11-27 15:17:37 +00:00

390 lines
9.3 KiB
C

/*-
* SPDX-License-Identifier: BSD-2-Clause-FreeBSD
*
* Copyright (c) 2004, 2007 Lukas Ertl
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
*
* THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*
*/
#include <sys/cdefs.h>
__FBSDID("$FreeBSD$");
#include <sys/param.h>
#include <sys/libkern.h>
#include <sys/malloc.h>
#include <geom/geom.h>
#include <geom/vinum/geom_vinum_var.h>
#include <geom/vinum/geom_vinum.h>
/* General 'remove' routine. */
void
gv_remove(struct g_geom *gp, struct gctl_req *req)
{
struct gv_softc *sc;
struct gv_volume *v;
struct gv_plex *p;
struct gv_sd *s;
struct gv_drive *d;
int *argc, *flags;
char *argv, buf[20];
int i, type;
argc = gctl_get_paraml(req, "argc", sizeof(*argc));
if (argc == NULL || *argc == 0) {
gctl_error(req, "no arguments given");
return;
}
flags = gctl_get_paraml(req, "flags", sizeof(*flags));
if (flags == NULL) {
gctl_error(req, "no flags given");
return;
}
sc = gp->softc;
/* XXX config locking */
for (i = 0; i < *argc; i++) {
snprintf(buf, sizeof(buf), "argv%d", i);
argv = gctl_get_param(req, buf, NULL);
if (argv == NULL)
continue;
type = gv_object_type(sc, argv);
switch (type) {
case GV_TYPE_VOL:
v = gv_find_vol(sc, argv);
/*
* If this volume has plexes, we want a recursive
* removal.
*/
if (!LIST_EMPTY(&v->plexes) && !(*flags & GV_FLAG_R)) {
gctl_error(req, "volume '%s' has attached "
"plexes - need recursive removal", v->name);
return;
}
gv_post_event(sc, GV_EVENT_RM_VOLUME, v, NULL, 0, 0);
break;
case GV_TYPE_PLEX:
p = gv_find_plex(sc, argv);
/*
* If this plex has subdisks, we want a recursive
* removal.
*/
if (!LIST_EMPTY(&p->subdisks) &&
!(*flags & GV_FLAG_R)) {
gctl_error(req, "plex '%s' has attached "
"subdisks - need recursive removal",
p->name);
return;
}
/* Don't allow removal of the only plex of a volume. */
if (p->vol_sc != NULL && p->vol_sc->plexcount == 1) {
gctl_error(req, "plex '%s' is still attached "
"to volume '%s'", p->name, p->volume);
return;
}
gv_post_event(sc, GV_EVENT_RM_PLEX, p, NULL, 0, 0);
break;
case GV_TYPE_SD:
s = gv_find_sd(sc, argv);
/* Don't allow removal if attached to a plex. */
if (s->plex_sc != NULL) {
gctl_error(req, "subdisk '%s' is still attached"
" to plex '%s'", s->name, s->plex_sc->name);
return;
}
gv_post_event(sc, GV_EVENT_RM_SD, s, NULL, 0, 0);
break;
case GV_TYPE_DRIVE:
d = gv_find_drive(sc, argv);
/* We don't allow to remove open drives. */
if (gv_consumer_is_open(d->consumer) &&
!(*flags & GV_FLAG_F)) {
gctl_error(req, "drive '%s' is open", d->name);
return;
}
/* A drive with subdisks needs a recursive removal. */
/* if (!LIST_EMPTY(&d->subdisks) &&
!(*flags & GV_FLAG_R)) {
gctl_error(req, "drive '%s' still has subdisks"
" - need recursive removal", d->name);
return;
}*/
gv_post_event(sc, GV_EVENT_RM_DRIVE, d, NULL, *flags,
0);
break;
default:
gctl_error(req, "unknown object '%s'", argv);
return;
}
}
gv_post_event(sc, GV_EVENT_SAVE_CONFIG, sc, NULL, 0, 0);
}
/* Resets configuration */
int
gv_resetconfig(struct gv_softc *sc)
{
struct gv_drive *d, *d2;
struct gv_volume *v, *v2;
struct gv_plex *p, *p2;
struct gv_sd *s, *s2;
/* First make sure nothing is open. */
LIST_FOREACH_SAFE(d, &sc->drives, drive, d2) {
if (gv_consumer_is_open(d->consumer)) {
return (GV_ERR_ISBUSY);
}
}
/* Make sure nothing is going on internally. */
LIST_FOREACH_SAFE(p, &sc->plexes, plex, p2) {
if (p->flags & (GV_PLEX_REBUILDING | GV_PLEX_GROWING))
return (GV_ERR_ISBUSY);
}
/* Then if not, we remove everything. */
LIST_FOREACH_SAFE(s, &sc->subdisks, sd, s2)
gv_rm_sd(sc, s);
LIST_FOREACH_SAFE(d, &sc->drives, drive, d2)
gv_rm_drive(sc, d, 0);
LIST_FOREACH_SAFE(p, &sc->plexes, plex, p2)
gv_rm_plex(sc, p);
LIST_FOREACH_SAFE(v, &sc->volumes, volume, v2)
gv_rm_vol(sc, v);
gv_post_event(sc, GV_EVENT_SAVE_CONFIG, sc, NULL, 0, 0);
return (0);
}
/* Remove a volume. */
void
gv_rm_vol(struct gv_softc *sc, struct gv_volume *v)
{
struct g_provider *pp;
struct gv_plex *p, *p2;
KASSERT(v != NULL, ("gv_rm_vol: NULL v"));
pp = v->provider;
KASSERT(pp != NULL, ("gv_rm_vol: NULL pp"));
/* Check if any of our consumers is open. */
if (gv_provider_is_open(pp)) {
G_VINUM_DEBUG(0, "unable to remove %s: volume still in use",
v->name);
return;
}
/* Remove the plexes our volume has. */
LIST_FOREACH_SAFE(p, &v->plexes, in_volume, p2)
gv_rm_plex(sc, p);
/* Clean up. */
LIST_REMOVE(v, volume);
g_free(v);
/* Get rid of the volume's provider. */
if (pp != NULL) {
g_topology_lock();
g_wither_provider(pp, ENXIO);
g_topology_unlock();
}
}
/* Remove a plex. */
void
gv_rm_plex(struct gv_softc *sc, struct gv_plex *p)
{
struct gv_volume *v;
struct gv_sd *s, *s2;
KASSERT(p != NULL, ("gv_rm_plex: NULL p"));
v = p->vol_sc;
/* Check if any of our consumers is open. */
if (v != NULL && gv_provider_is_open(v->provider) && v->plexcount < 2) {
G_VINUM_DEBUG(0, "unable to remove %s: volume still in use",
p->name);
return;
}
/* Remove the subdisks our plex has. */
LIST_FOREACH_SAFE(s, &p->subdisks, in_plex, s2)
gv_rm_sd(sc, s);
v = p->vol_sc;
/* Clean up and let our geom fade away. */
LIST_REMOVE(p, plex);
if (p->vol_sc != NULL) {
p->vol_sc->plexcount--;
LIST_REMOVE(p, in_volume);
p->vol_sc = NULL;
/* Correctly update the volume size. */
gv_update_vol_size(v, gv_vol_size(v));
}
g_free(p);
}
/* Remove a subdisk. */
void
gv_rm_sd(struct gv_softc *sc, struct gv_sd *s)
{
struct gv_plex *p;
struct gv_volume *v;
KASSERT(s != NULL, ("gv_rm_sd: NULL s"));
p = s->plex_sc;
v = NULL;
/* Clean up. */
if (p != NULL) {
LIST_REMOVE(s, in_plex);
s->plex_sc = NULL;
p->sdcount--;
/* Update the plexsize. */
p->size = gv_plex_size(p);
v = p->vol_sc;
if (v != NULL) {
/* Update the size of our plex' volume. */
gv_update_vol_size(v, gv_vol_size(v));
}
}
if (s->drive_sc && !(s->drive_sc->flags & GV_DRIVE_REFERENCED))
LIST_REMOVE(s, from_drive);
LIST_REMOVE(s, sd);
gv_free_sd(s);
g_free(s);
}
/* Remove a drive. */
void
gv_rm_drive(struct gv_softc *sc, struct gv_drive *d, int flags)
{
struct g_consumer *cp;
struct gv_freelist *fl, *fl2;
struct gv_plex *p;
struct gv_sd *s, *s2;
struct gv_volume *v;
struct gv_drive *d2;
int err;
KASSERT(d != NULL, ("gv_rm_drive: NULL d"));
cp = d->consumer;
if (cp != NULL) {
g_topology_lock();
err = g_access(cp, 0, 1, 0);
g_topology_unlock();
if (err) {
G_VINUM_DEBUG(0, "%s: unable to access '%s', "
"errno: %d", __func__, cp->provider->name, err);
return;
}
/* Clear the Vinum Magic. */
d->hdr->magic = GV_NOMAGIC;
err = gv_write_header(cp, d->hdr);
if (err)
G_VINUM_DEBUG(0, "gv_rm_drive: error writing header to"
" '%s', errno: %d", cp->provider->name, err);
g_topology_lock();
g_access(cp, -cp->acr, -cp->acw, -cp->ace);
g_detach(cp);
g_destroy_consumer(cp);
g_topology_unlock();
}
/* Remove all associated subdisks, plexes, volumes. */
if (flags & GV_FLAG_R) {
if (!LIST_EMPTY(&d->subdisks)) {
LIST_FOREACH_SAFE(s, &d->subdisks, from_drive, s2) {
p = s->plex_sc;
if (p != NULL) {
v = p->vol_sc;
if (v != NULL)
gv_rm_vol(sc, v);
}
}
}
}
/* Clean up. */
LIST_FOREACH_SAFE(fl, &d->freelist, freelist, fl2) {
LIST_REMOVE(fl, freelist);
g_free(fl);
}
LIST_REMOVE(d, drive);
g_free(d->hdr);
/* Put ourself into referenced state if we have subdisks. */
if (d->sdcount > 0) {
d->consumer = NULL;
d->hdr = NULL;
d->flags |= GV_DRIVE_REFERENCED;
snprintf(d->device, sizeof(d->device), "???");
d->size = 0;
d->avail = 0;
d->freelist_entries = 0;
LIST_FOREACH(s, &d->subdisks, from_drive) {
s->flags |= GV_SD_TASTED;
gv_set_sd_state(s, GV_SD_DOWN, GV_SETSTATE_FORCE);
}
/* Shuffle around so we keep gv_is_newer happy. */
LIST_REMOVE(d, drive);
d2 = LIST_FIRST(&sc->drives);
if (d2 == NULL)
LIST_INSERT_HEAD(&sc->drives, d, drive);
else
LIST_INSERT_AFTER(d2, d, drive);
return;
}
g_free(d);
gv_save_config(sc);
}