freebsd-skq/sys/net/sff8436.h
Alexander V. Chernikov a18742e938 Add SFF-8024 Extended Specification Compliance
Submitted by:		markb_mellanox.com
MFC after:		2 weeks
Differential Revision:	https://reviews.freebsd.org/D4666
2015-12-28 09:26:07 +00:00

214 lines
8.3 KiB
C
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

/*-
* Copyright (c) 2014 Yandex LLC.
*
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*
* $FreeBSD$
*/
/*
* The following set of constants are from Document SFF-8436
* "QSFP+ 10 Gbs 4X PLUGGABLE TRANSCEIVER" revision 4.8 dated October 31, 2013
*
* This SFF standard defines the following QSFP+ memory address module:
*
* 1) 256-byte addressable block and 128-byte pages
* 2) Lower 128-bytes addresses always refer to the same page
* 3) Upper address space may refer to different pages depending on
* "page select" byte value.
*
* Map description:
*
* Serial address 0xA02:
*
* Lower bits
* 0-127 Monitoring data & page select byte
* 128-255:
*
* Page 00:
* 128-191 Base ID Fields
* 191-223 Extended ID
* 223-255 Vendor Specific ID
*
* Page 01 (optional):
* 128-255 App-specific data
*
* Page 02 (optional):
* 128-255 User EEPROM Data
*
* Page 03 (optional for Cable Assmeblies)
* 128-223 Thresholds
* 225-237 Vendor Specific
* 238-253 Channel Controls/Monitor
* 254-255 Reserverd
*
* All these values are read across an I2C (i squared C) bus.
*/
#define SFF_8436_BASE 0xA0 /* Base address for all requests */
/* Table 17 - Lower Memory Map */
enum {
SFF_8436_MID = 0, /* Copy of SFF_8436_ID field */
SFF_8436_STATUS = 1, /* 2-bytes status (Table 18) */
SFF_8436_INTR_START = 3, /* Interrupt flags (Tables 19-21) */
SFF_8436_INTR_END = 21,
SFF_8436_MODMON_START = 22, /* Module monitors (Table 22 */
SFF_8436_TEMP = 22, /* Internally measured module temp */
SFF_8436_VCC = 26, /* Internally mesasure module
* supplied voltage */
SFF_8436_MODMON_END = 33,
SFF_8436_CHMON_START = 34, /* Channel monitors (Table 23) */
SFF_8436_RX_CH1_MSB = 34, /* Internally measured RX input power */
SFF_8436_RX_CH1_LSB = 35, /* for channel 1 */
SFF_8436_RX_CH2_MSB = 36, /* Internally measured RX input power */
SFF_8436_RX_CH2_LSB = 37, /* for channel 2 */
SFF_8436_RX_CH3_MSB = 38, /* Internally measured RX input power */
SFF_8436_RX_CH3_LSB = 39, /* for channel 3 */
SFF_8436_RX_CH4_MSB = 40, /* Internally measured RX input power */
SFF_8436_RX_CH4_LSB = 41, /* for channel 4 */
SFF_8436_TX_CH1_MSB = 42, /* Internally measured TX bias */
SFF_8436_TX_CH1_LSB = 43, /* for channel 1 */
SFF_8436_TX_CH2_MSB = 44, /* Internally measured TX bias */
SFF_8436_TX_CH2_LSB = 45, /* for channel 2 */
SFF_8436_TX_CH3_MSB = 46, /* Internally measured TX bias */
SFF_8436_TX_CH3_LSB = 47, /* for channel 3 */
SFF_8436_TX_CH4_MSB = 48, /* Internally measured TX bias */
SFF_8436_TX_CH4_LSB = 49, /* for channel 4 */
SFF_8436_CHANMON_END = 81,
SFF_8436_CONTROL_START = 86, /* Control (Table 24) */
SFF_8436_CONTROL_END = 97,
SFF_8436_MASKS_START = 100, /* Module/channel masks (Table 25) */
SFF_8436_MASKS_END = 106,
SFF_8436_CHPASSWORD = 119, /* Password change entry (4 bytes) */
SFF_8436_PASSWORD = 123, /* Password entry area (4 bytes) */
SFF_8436_PAGESEL = 127, /* Page select byte */
};
/* Table 18 - Status Indicators bits */
/* Byte 1: all bits reserved */
/* Byte 2 bits */
#define SFF_8436_STATUS_FLATMEM (1 << 2) /* Upper memory flat or paged
* 0 = paging, 1=Page 0 only */
#define SFF_8436_STATUS_INTL (1 << 1) /* Digital state of the intL
* Interrupt output pin */
#define SFF_8436_STATUS_NOTREADY 1 /* Module has not yet achieved
* power up and memory data is not
* ready. 0=data is ready */
/*
* Upper page 0 definitions:
* Table 29 - Serial ID: Data fields.
*
* Note that this table is mostly the same as used in SFF-8472.
* The only differenee is address shift: +128 bytes.
*/
enum {
SFF_8436_ID = 128, /* Module Type (defined in sff8472.h) */
SFF_8436_EXT_ID = 129, /* Extended transceiver type
* (Table 31) */
SFF_8436_CONNECTOR = 130, /* Connector type (Table 32) */
SFF_8436_TRANS_START = 131, /* Electric or Optical Compatibility
* (Table 33) */
SFF_8436_CODE_E1040100G = 131, /* 10/40/100G Ethernet Compliance Code */
SFF_8436_CODE_SONET = 132, /* SONET Compliance codes */
SFF_8436_CODE_SATA = 133, /* SAS/SATA compliance codes */
SFF_8436_CODE_E1G = 134, /* Gigabit Ethernet Compliant codes */
SFF_8436_CODE_FC_START = 135, /* FC link/media/speed */
SFF_8436_CODE_FC_END = 138,
SFF_8436_TRANS_END = 138,
SFF_8436_ENCODING = 139, /* Encoding Code for high speed
* serial encoding algorithm (see
* Table 34) */
SFF_8436_BITRATE = 140, /* Nominal signaling rate, units
* of 100MBd. */
SFF_8436_RATEID = 141, /* Extended RateSelect Compliance
* (see Table 35) */
SFF_8436_LEN_SMF_KM = 142, /* Link length supported for single
* mode fiber, units of km */
SFF_8436_LEN_OM3 = 143, /* Link length supported for 850nm
* 50um multimode fiber, units of 2 m */
SFF_8436_LEN_OM2 = 144, /* Link length supported for 50 um
* OM2 fiber, units of 1 m */
SFF_8436_LEN_OM1 = 145, /* Link length supported for 1310 nm
* 50um multi-mode fiber, units of 1m*/
SFF_8436_LEN_ASM = 144, /* Link length of passive cable assembly
* Length is specified as in the INF
* 8074, units of 1m. 0 means this is
* not value assembly. Value of 255
* means thet the Module supports length
* greater than 254 m. */
SFF_8436_DEV_TECH = 147, /* Device/transmitter technology,
* see Table 36/37 */
SFF_8436_VENDOR_START = 148, /* Vendor name, 16 bytes, padded
* right with 0x20 */
SFF_8436_VENDOR_END = 163,
SFF_8436_EXTMODCODE = 164, /* Extended module code, Table 164 */
SFF_8436_VENDOR_OUI_START = 165 , /* Vendor OUI SFP vendor IEEE
* company ID */
SFF_8436_VENDOR_OUI_END = 167,
SFF_8436_PN_START = 168, /* Vendor PN, padded right with 0x20 */
SFF_8436_PN_END = 183,
SFF_8436_REV_START = 184, /* Vendor Revision, padded right 0x20 */
SFF_8436_REV_END = 185,
SFF_8436_WAVELEN_START = 186, /* Wavelength Laser wavelength
* (Passive/Active Cable
* Specification Compliance) */
SFF_8436_WAVELEN_END = 189,
SFF_8436_MAX_CASE_TEMP = 190, /* Allows to specify maximum temp
* above 70C. Maximum case temperature is
* an 8-bit value in Degrees C. A value
*of 0 implies the standard 70C rating.*/
SFF_8436_CC_BASE = 191, /* CC_BASE Check code for Base ID
* Fields (first 63 bytes) */
/* Extended ID fields */
SFF_8436_OPTIONS_START = 192, /* Options Indicates which optional
* transceiver signals are
* implemented (see Table 39) */
SFF_8436_OPTIONS_END = 195,
SFF_8436_SN_START = 196, /* Vendor SN, riwght padded with 0x20 */
SFF_8436_SN_END = 211,
SFF_8436_DATE_START = 212, /* Vendors manufacturing date code
* (see Table 40) */
SFF_8436_DATE_END = 219,
SFF_8436_DIAG_TYPE = 220, /* Diagnostic Monitoring Type
* Indicates which type of
* diagnostic monitoring is
* implemented (if any) in the
* transceiver (see Table 41) */
SFF_8436_ENHANCED = 221, /* Enhanced Options Indicates which
* optional features are implemented
* (if any) in the transceiver
* (see Table 42) */
SFF_8636_BITRATE = 222, /* Nominal bit rate per channel, units
* of 250 Mbps */
SFF_8436_CC_EXT = 223, /* Check code for the Extended ID
* Fields (bytes 192-222 incl) */
SFF_8436_VENDOR_RSRVD_START = 224,
SFF_8436_VENDOR_RSRVD_END = 255,
};