Testing shown that both original queued design with separate task queue,
and recent direct execution design had significant flaw: If abort request
arrives just after the victim, the last one may not be in the ooa_queue
yet, and so invisible for the task management function.
Unlike original queued implementation, use same queue for all SCSI and
TASK requests from the same initiator. That avoids races between them:
task functions are always executed in proper time, relatively to other
requests.