7027b9cda4
defect information it has before grabbing the full defect list. This works around a bug with some Hitachi drives that generate data overrun errors when they are asked for more defect data than they have. The change is done in a spec-compliant way, so it should have no negative impact on drives that don't have this issue. This is based on work originally done at Sandvine. scsi_da.h: Add a define for the maximum amount of data that can be contained in a defect list. camcontrol.c: Update the readdefects() function to issue an initial command to determine the length of the defect list, and then use that length in the request for the full defect list. camcontrol.8: Add a note that some drives will report 0 defects available if you don't request either the PLIST or GLIST. Submitted by: Mark Johnston <markjdb@gmail.com> (original version) MFC after: 3 days |
||
---|---|---|
.. | ||
camcontrol.8 | ||
camcontrol.c | ||
camcontrol.h | ||
fwdownload.c | ||
Makefile | ||
modeedit.c | ||
progress.c | ||
progress.h | ||
util.c |