1537078d8f
Mainly focus on files that use BSD 2-Clause license, however the tool I was using misidentified many licenses so this was mostly a manual - error prone - task. The Software Package Data Exchange (SPDX) group provides a specification to make it easier for automated tools to detect and summarize well known opensource licenses. We are gradually adopting the specification, noting that the tags are considered only advisory and do not, in any way, superceed or replace the license texts.
179 lines
4.3 KiB
C
179 lines
4.3 KiB
C
/*-
|
|
* SPDX-License-Identifier: BSD-2-Clause-FreeBSD
|
|
*
|
|
* Copyright (c) 2006 Marcel Moolenaar
|
|
* All rights reserved.
|
|
*
|
|
* Redistribution and use in source and binary forms, with or without
|
|
* modification, are permitted provided that the following conditions
|
|
* are met:
|
|
*
|
|
* 1. Redistributions of source code must retain the above copyright
|
|
* notice, this list of conditions and the following disclaimer.
|
|
* 2. Redistributions in binary form must reproduce the above copyright
|
|
* notice, this list of conditions and the following disclaimer in the
|
|
* documentation and/or other materials provided with the distribution.
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
|
|
* IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
|
|
* OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
|
|
* IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
|
|
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
|
|
* NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
|
* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
|
* THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
|
* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
|
|
* THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
*/
|
|
|
|
#include <sys/cdefs.h>
|
|
__FBSDID("$FreeBSD$");
|
|
|
|
#include <sys/param.h>
|
|
#include <sys/systm.h>
|
|
#include <sys/bus.h>
|
|
#include <sys/rman.h>
|
|
#include <sys/sysctl.h>
|
|
|
|
#include <dev/puc/puc_bus.h>
|
|
#include <dev/puc/puc_cfg.h>
|
|
#include <dev/puc/puc_bfe.h>
|
|
|
|
int
|
|
puc_config(struct puc_softc *sc, enum puc_cfg_cmd cmd, int port, intptr_t *r)
|
|
{
|
|
const struct puc_cfg *cfg = sc->sc_cfg;
|
|
int error;
|
|
|
|
if (cfg->config_function != NULL) {
|
|
error = cfg->config_function(sc, cmd, port, r);
|
|
if (!error)
|
|
return (0);
|
|
} else
|
|
error = EDOOFUS;
|
|
|
|
switch (cmd) {
|
|
case PUC_CFG_GET_CLOCK:
|
|
if (cfg->clock < 0)
|
|
return (error);
|
|
*r = cfg->clock;
|
|
return (0);
|
|
case PUC_CFG_GET_DESC:
|
|
if (cfg->desc == NULL)
|
|
return (error);
|
|
*r = (intptr_t)cfg->desc;
|
|
return (0);
|
|
case PUC_CFG_GET_ILR:
|
|
*r = PUC_ILR_NONE;
|
|
return (0);
|
|
case PUC_CFG_GET_LEN:
|
|
/* The length of bus space needed by the port. */
|
|
*r = 8;
|
|
return (0);
|
|
case PUC_CFG_GET_NPORTS:
|
|
/* The number of ports on this card. */
|
|
switch (cfg->ports) {
|
|
case PUC_PORT_NONSTANDARD:
|
|
return (error);
|
|
case PUC_PORT_1P:
|
|
case PUC_PORT_1S:
|
|
*r = 1;
|
|
return (0);
|
|
case PUC_PORT_1S1P:
|
|
case PUC_PORT_2P:
|
|
case PUC_PORT_2S:
|
|
*r = 2;
|
|
return (0);
|
|
case PUC_PORT_1S2P:
|
|
case PUC_PORT_2S1P:
|
|
case PUC_PORT_3S:
|
|
*r = 3;
|
|
return (0);
|
|
case PUC_PORT_4S:
|
|
*r = 4;
|
|
return (0);
|
|
case PUC_PORT_4S1P:
|
|
*r = 5;
|
|
return (0);
|
|
case PUC_PORT_6S:
|
|
*r = 6;
|
|
return (0);
|
|
case PUC_PORT_8S:
|
|
*r = 8;
|
|
return (0);
|
|
case PUC_PORT_12S:
|
|
*r = 12;
|
|
return (0);
|
|
case PUC_PORT_16S:
|
|
*r = 16;
|
|
return (0);
|
|
}
|
|
break;
|
|
case PUC_CFG_GET_OFS:
|
|
/* The offset relative to the RID. */
|
|
if (cfg->d_ofs < 0)
|
|
return (error);
|
|
*r = port * cfg->d_ofs;
|
|
return (0);
|
|
case PUC_CFG_GET_RID:
|
|
/* The RID for this port. */
|
|
if (port == 0) {
|
|
if (cfg->rid < 0)
|
|
return (error);
|
|
*r = cfg->rid;
|
|
return (0);
|
|
}
|
|
if (cfg->d_rid < 0)
|
|
return (error);
|
|
if (cfg->rid < 0) {
|
|
error = puc_config(sc, PUC_CFG_GET_RID, 0, r);
|
|
if (error)
|
|
return (error);
|
|
} else
|
|
*r = cfg->rid;
|
|
*r += port * cfg->d_rid;
|
|
return (0);
|
|
case PUC_CFG_GET_TYPE:
|
|
/* The type of this port. */
|
|
if (cfg->ports == PUC_PORT_NONSTANDARD)
|
|
return (error);
|
|
switch (port) {
|
|
case 0:
|
|
if (cfg->ports == PUC_PORT_1P ||
|
|
cfg->ports == PUC_PORT_2P)
|
|
*r = PUC_TYPE_PARALLEL;
|
|
else
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
case 1:
|
|
if (cfg->ports == PUC_PORT_1S1P ||
|
|
cfg->ports == PUC_PORT_1S2P ||
|
|
cfg->ports == PUC_PORT_2P)
|
|
*r = PUC_TYPE_PARALLEL;
|
|
else
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
case 2:
|
|
if (cfg->ports == PUC_PORT_1S2P ||
|
|
cfg->ports == PUC_PORT_2S1P)
|
|
*r = PUC_TYPE_PARALLEL;
|
|
else
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
case 4:
|
|
if (cfg->ports == PUC_PORT_4S1P)
|
|
*r = PUC_TYPE_PARALLEL;
|
|
else
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
}
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
case PUC_CFG_SETUP:
|
|
*r = ENXIO;
|
|
return (0);
|
|
}
|
|
|
|
return (ENXIO);
|
|
}
|