would be 93C46(1Kbit) or 93C56(2Kbit). One of differences between them
is number of address lines required to access the EEPROM. For example,
93C56 EEPROM needs 8 address lines to read/write data. If 93C56
recevied premature end of required number of serial clock(CLK) to set
OP code/address of EEPROM, the result would be unexpected behavior.
Previously it tried to detect 93C46, which requires 6 address lines,
and then assumed it would be 93C56 if read data was not expected
value. However, this approach didn't work in some models/situations
as 93C56 requries 8 address lines to access its data. In order to fix
it, change EEPROM probing order such that 93C56 is detected reliably.
While I'm here change hard-coded address line numbers with defined
constant to enhance readability.
PR: 112710
Approved by: re (mux)