5addfd60d6
to be the same as -ragged in the current implementation) to -ragged. With mdocNG, -filled displays produce the correct output, formatted and justified to both margins.
222 lines
5.4 KiB
Groff
222 lines
5.4 KiB
Groff
.\" Copyright (c) 1983, 1991, 1993
|
|
.\" The Regents of the University of California. All rights reserved.
|
|
.\"
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
.\" modification, are permitted provided that the following conditions
|
|
.\" are met:
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer.
|
|
.\" 2. Redistributions in binary form must reproduce the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer in the
|
|
.\" documentation and/or other materials provided with the distribution.
|
|
.\" 3. All advertising materials mentioning features or use of this software
|
|
.\" must display the following acknowledgement:
|
|
.\" This product includes software developed by the University of
|
|
.\" California, Berkeley and its contributors.
|
|
.\" 4. Neither the name of the University nor the names of its contributors
|
|
.\" may be used to endorse or promote products derived from this software
|
|
.\" without specific prior written permission.
|
|
.\"
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
|
|
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
|
|
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
.\" SUCH DAMAGE.
|
|
.\"
|
|
.\" @(#)rmt.8 8.3 (Berkeley) 6/1/94
|
|
.\" $FreeBSD$
|
|
.\"
|
|
.Dd June 1, 1994
|
|
.Dt RMT 8
|
|
.Os BSD 4.2
|
|
.Sh NAME
|
|
.Nm rmt
|
|
.Nd remote magtape protocol module
|
|
.Sh SYNOPSIS
|
|
.Nm
|
|
.Sh DESCRIPTION
|
|
.Nm Rmt
|
|
is a program used by the remote dump and restore programs
|
|
in manipulating a magnetic tape drive through an interprocess
|
|
communication connection.
|
|
.Nm Rmt
|
|
is normally started up with an
|
|
.Xr rexec 3
|
|
or
|
|
.Xr rcmd 3
|
|
call.
|
|
.Pp
|
|
The
|
|
.Nm
|
|
program accepts requests specific to the manipulation of
|
|
magnetic tapes, performs the commands, then responds with
|
|
a status indication. All responses are in
|
|
.Tn ASCII
|
|
and in
|
|
one of two forms.
|
|
Successful commands have responses of:
|
|
.Bd -ragged -offset indent
|
|
.Sm off
|
|
.Sy A Ar number No \en
|
|
.Sm on
|
|
.Ed
|
|
.Pp
|
|
.Ar Number
|
|
is an
|
|
.Tn ASCII
|
|
representation of a decimal number.
|
|
Unsuccessful commands are responded to with:
|
|
.Bd -ragged -offset indent
|
|
.Sm off
|
|
.Xo Sy E Ar error-number
|
|
.No \en Ar error-message
|
|
.No \en
|
|
.Xc
|
|
.Sm on
|
|
.Ed
|
|
.Pp
|
|
.Ar Error-number
|
|
is one of the possible error
|
|
numbers described in
|
|
.Xr intro 2
|
|
and
|
|
.Ar error-message
|
|
is the corresponding error string as printed
|
|
from a call to
|
|
.Xr perror 3 .
|
|
The protocol is comprised of the
|
|
following commands, which are sent as indicated - no spaces are supplied
|
|
between the command and its arguments, or between its arguments, and
|
|
.Ql \en
|
|
indicates that a newline should be supplied:
|
|
.Bl -tag -width Ds
|
|
.Sm off
|
|
.It Xo Sy \&O Ar device
|
|
.No \en Ar mode No \en
|
|
.Xc
|
|
.Sm on
|
|
Open the specified
|
|
.Ar device
|
|
using the indicated
|
|
.Ar mode .
|
|
.Ar Device
|
|
is a full pathname and
|
|
.Ar mode
|
|
is an
|
|
.Tn ASCII
|
|
representation of a decimal
|
|
number suitable for passing to
|
|
.Xr open 2 .
|
|
If a device had already been opened, it is
|
|
closed before a new open is performed.
|
|
.Sm off
|
|
.It Xo Sy C Ar device No \en
|
|
.Xc
|
|
.Sm on
|
|
Close the currently open device. The
|
|
.Ar device
|
|
specified is ignored.
|
|
.Sm off
|
|
.It Xo Sy L
|
|
.Ar whence No \en
|
|
.Ar offset No \en
|
|
.Xc
|
|
.Sm on
|
|
Perform an
|
|
.Xr lseek 2
|
|
operation using the specified parameters.
|
|
The response value is that returned from the
|
|
.Xr lseek
|
|
call.
|
|
.Sm off
|
|
.It Sy W Ar count No \en
|
|
.Sm on
|
|
Write data onto the open device.
|
|
.Nm Rmt
|
|
reads
|
|
.Ar count
|
|
bytes from the connection, aborting if
|
|
a premature end-of-file is encountered.
|
|
The response value is that returned from
|
|
the
|
|
.Xr write 2
|
|
call.
|
|
.Sm off
|
|
.It Sy R Ar count No \en
|
|
.Sm on
|
|
Read
|
|
.Ar count
|
|
bytes of data from the open device.
|
|
If
|
|
.Ar count
|
|
exceeds the size of the data buffer (10 kilobytes), it is
|
|
truncated to the data buffer size.
|
|
.Nm Rmt
|
|
then performs the requested
|
|
.Xr read 2
|
|
and responds with
|
|
.Sm off
|
|
.Sy A Ar count-read No \en
|
|
.Sm on
|
|
if the read was
|
|
successful; otherwise an error in the
|
|
standard format is returned. If the read
|
|
was successful, the data read is then sent.
|
|
.Sm off
|
|
.It Xo Sy I Ar operation
|
|
.No \en Ar count No \en
|
|
.Xc
|
|
.Sm on
|
|
Perform a
|
|
.Dv MTIOCOP
|
|
.Xr ioctl 2
|
|
command using the specified parameters.
|
|
The parameters are interpreted as the
|
|
.Tn ASCII
|
|
representations of the decimal values
|
|
to place in the
|
|
.Ar mt_op
|
|
and
|
|
.Ar mt_count
|
|
fields of the structure used in the
|
|
.Xr ioctl 2
|
|
call. The return value is the
|
|
.Ar count
|
|
parameter when the operation is successful.
|
|
.It Sy S
|
|
Return the status of the open device, as
|
|
obtained with a
|
|
.Dv MTIOCGET
|
|
.Xr ioctl 2
|
|
call. If the operation was successful,
|
|
an ``ack'' is sent with the size of the
|
|
status buffer, then the status buffer is
|
|
sent (in binary).
|
|
.El
|
|
.Pp
|
|
Any other command causes
|
|
.Nm
|
|
to exit.
|
|
.Sh DIAGNOSTICS
|
|
All responses are of the form described above.
|
|
.Sh SEE ALSO
|
|
.Xr rcmd 3 ,
|
|
.Xr rexec 3 ,
|
|
.Xr mtio 4 ,
|
|
.Xr rdump 8 ,
|
|
.Xr rrestore 8
|
|
.Sh BUGS
|
|
People should be discouraged from using this for a remote
|
|
file access protocol.
|
|
.Sh HISTORY
|
|
The
|
|
.Nm
|
|
command appeared in
|
|
.Bx 4.2 .
|