pfg 1537078d8f sys/dev: further adoption of SPDX licensing ID tags.
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.

The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
2017-11-27 14:52:40 +00:00

56 lines
2.4 KiB
C

/*-
* SPDX-License-Identifier: BSD-2-Clause-FreeBSD
*
* Copyright (c) 2010-2011 Adrian Chadd, Xenion Pty Ltd.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*
* $FreeBSD$
*/
#ifndef __ATH_AR9280_OLC_H__
#define __ATH_AR9280_OLC_H__
extern void ar9280olcInit(struct ath_hal *ah);
/* OLC TX power control */
extern void ar9280olcGetPDADCs(struct ath_hal *ah, uint32_t initTxGain,
int txPower, uint8_t *pPDADCValues);
extern void ar9280olcGetTxGainIndex(struct ath_hal *ah,
const struct ieee80211_channel *chan,
struct calDataPerFreqOpLoop *rawDatasetOpLoop,
uint8_t *calChans, uint16_t availPiers, uint8_t *pwr, uint8_t *pcdacIdx);
extern void ar9280GetGainBoundariesAndPdadcs(struct ath_hal *ah,
const struct ieee80211_channel *chan, CAL_DATA_PER_FREQ *pRawDataSet,
uint8_t * bChans, uint16_t availPiers,
uint16_t tPdGainOverlap, int16_t *pMinCalPower,
uint16_t * pPdGainBoundaries, uint8_t * pPDADCValues,
uint16_t numXpdGains);
extern HAL_BOOL ar9280SetPowerCalTable(struct ath_hal *ah,
struct ar5416eeprom *pEepData, const struct ieee80211_channel *chan,
int16_t *pTxPowerIndexOffset);
/* OLC calibration */
extern void ar9280olcTemperatureCompensation(struct ath_hal *ah);
#endif